Distribution Substation Performance Improvement: Case Study

被引:0
|
作者
Abdo, Ali [1 ]
Siam, Jamal [1 ]
Miqdad, Oday [1 ]
Awesat, Olfat [1 ]
机构
[1] Birzeit Univ, Fac Engn & Technol, Dept Elect & Comp Engn, Ramallah, Palestine
关键词
Distribution station; Medium voltage substation; Power factor correction; ONAF transformer; NETWORKS; SYSTEMS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electric power quality is one of the most challenging topics for electrical companies throughout the world. The planning and the structure of distribution stations (DS) play an important role in the power quality and the performance of these stations. This paper studies the structure and the components of the distribution substation and presents some technical ideas in order to enhance its performance. The effect of (33/0.4) kV transformer, ONAF transformers, and power factor correction, will be discussed for higher power distribution reliability in terms of peak-load management and power delivery interruptions. The medium voltage outdoor distribution station of (33/11) kV in AL-Tur in Palestine is adopted as a case study to illustrate the proposed technical actions.
引用
收藏
页码:193 / 204
页数:12
相关论文
共 50 条
  • [21] The Measurement System Analysis as a Performance Improvement Catalyst: A Case Study
    Cagnazzo, Luca
    Sibalija, Tatjana
    Majstorovic, Vidosav
    BUSINESS PERFORMANCE MEASUREMENT AND MANAGEMENT: NEW CONTEXTS, THEMES AND CHALLENGES, 2010, : 269 - +
  • [22] Intelligent Approach for Improvement of BIPV Systems Performance: Case Study
    Craciunescu, Dan
    Fara, Laurentiu
    Dabija, Ana-Maria
    Sterian, Paul
    Fara, Silvian
    3RD WORLD MULTIDISCIPLINARY CIVIL ENGINEERING, ARCHITECTURE, URBAN PLANNING SYMPOSIUM (WMCAUS 2018), 2019, 471
  • [23] Industrial gas turbine performance prediction and improvement – a case study
    Mzad H.
    Bennour F.
    Energy Harvesting and Systems, 2024, 11 (01)
  • [24] Performance Improvement Modelling (Case Study: Micro and Small Enterprise)
    Oktavina, Rakhma
    Siringiringo, Hotniar
    Sudaryanto
    INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS (IMECS 2010), VOLS I-III, 2010, : 1716 - 1721
  • [25] A case study assessment of performance measurement in distribution centers
    Kuo, CH
    Dunn, KD
    Randhawa, SU
    INDUSTRIAL MANAGEMENT & DATA SYSTEMS, 1999, 99 (1-2) : 54 - 63
  • [26] Study of the Electromagnetic Field Distribution inside a HV/MV Substation
    Munteanu, Calin
    Purcar, Marius
    Muresan, Teofil
    Pop, Alina
    Rizzo, Renato
    2017 7TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS), 2017,
  • [27] Substation Flood Program and Flood Hardening Case Study
    Costa, Richard E.
    McAllister, Gary R.
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [28] A study on improvement of IEC 61850-based substation restoration scheme for minimizing outage area in case of breaker failure
    Kim M.-S.
    Kang S.-H.
    Transactions of the Korean Institute of Electrical Engineers, 2020, 69 (03): : 396 - 401
  • [29] Improvement of fragilities for electrical substation equipment
    Anagnos, T
    OPTIMIZING POST-EARTHQUAKE LIFELINE SYSTEM RELIABILITY, 1999, (16): : 673 - 682
  • [30] Improvement of fragilities for electrical substation equipment
    San Jose State Univ, San Jose, United States
    Tech Council Lifeline Earthquake Eng Monogr, 16 (673-682):