Robust quantification of the SMN gene copy number by real-time TaqMan PCR

被引:36
|
作者
Gomez-Curet, Ilsa
Robinson, Karyn G.
Funanage, Vicky L.
Crawford, Thomas O.
Scavina, Mena
Wang, Wenlan
机构
[1] Alfred I Dupont Hosp Children, Nemours Biomed Res, Wilmington, DE 19899 USA
[2] Thomas Jefferson Univ, Dept Pediat, Philadelphia, PA USA
[3] Johns Hopkins Univ, Dept Neurol & Pediat, Baltimore, MD USA
关键词
spinal muscular atrophy; survival motor neuron gene; gene copy number assay; real-time PCR;
D O I
10.1007/s10048-007-0093-1
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Spinal muscular atrophy (SMA) is an autosomal recessive disease caused by mutation or deletion of the survival motor neuron gene 1 (SMN1). The highly homologous gene, SMN2, is present in all patients, but it cannot compensate for loss of SMN1. SMN2 differs from SMN1 by a few nucleotide changes, but a C -> T transition in exon 7 leads to exon skipping. As a result, most transcripts from the SMN2 gene lack exon 7. Although SMN1 is the disease-determining gene, the number of SMN2 copies appears to modulate SMA clinical phenotypes. Thus, determining the SMN copy number is important for clinical diagnosis and prognosis. We have developed a quantitative real-time TaqMan polymerase chain reaction assay for both the SMN1 and SMN2 genes, in which reliable copy number determination was possible on deoxyribonucleic acid samples obtained by two different isolation methods and from two different sources (human blood and skin fibroblasts). For SMN1, allele specificity was attained solely by addition of an allele-specific forward primer and, for SMN2, by addition of a specific forward primer and a nonextending oligonucleotide (SMN1 blocker) that reduced nonspecific amplification from SMN1 to a negligible level. We validated the reliability of this real-time polymerase chain reaction approach and found that the coefficient of variation for all the gene copy number measurements was below 10%. Quantitative analysis of the SMN copy number in SMA fibroblasts by this approach showed deletion of SMN1 and an inverse correlation between the SMN2 copy number and severity of the disease.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [41] A TaqMan-based real-time PCR for detection and quantification of porcine parvovirus 4
    Gava, Danielle
    Souza, Carine K.
    Schaefer, Rejane
    Vincent, Amy L.
    Cantao, Mauricio E.
    Coldebella, Arlei
    Ciacci-Zanella, Janice R.
    JOURNAL OF VIROLOGICAL METHODS, 2015, 219 : 14 - 17
  • [42] Rapid Identification and Quantification of Lactobacillus rhamnosus by Real-Time PCR Using a TaqMan Probe
    Okai, Chiaki
    Itani, Yoshiro
    Furuta, Akira
    Mizunoe, Yoshimitsu
    Iwase, Tadayuki
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2019, 72 (05) : 323 - 325
  • [43] DETECTION AND QUANTIFICATION OF SALMONELLA AND LISTERIA MONOCYTOGENES STRAINS IN FOOD BY TAQMAN REAL-TIME PCR
    Sabie, Alina Vlad
    Floristean, V.
    Carare, C. Carp
    Obada, M.
    Cretu, Carmen
    Carare, M. Carp
    REVISTA ROMANA DE MEDICINA VETERINARA, 2012, 22 (04): : 59 - 68
  • [44] Development and validation of TaqMan real-time PCR assays for quantification of chicken adulteration in hamburgers
    Sarlak, Zahra
    Shojaee-Aliabadi, Saeedeh
    Rezvani, Nayebali
    Hosseini, Hedayat
    Rouhi, Milad
    Dastafkan, Zahra
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 106
  • [45] Real-time PCR quantification of cytomegalovirus in aggressive periodontitis lesions using TaqMan technology
    Kubar, A
    Saygun, I
    Yapar, M
    Özdemir, A
    Slots, J
    JOURNAL OF PERIODONTAL RESEARCH, 2004, 39 (02) : 81 - 86
  • [47] Development of real-time PCR (TaqMan®) assays for the detection and quantification of Botrytis cinerea in planta
    Suarez, MB
    Walsh, K
    Boonham, N
    O' Neill, T
    Pearson, S
    Barker, I
    PLANT PHYSIOLOGY AND BIOCHEMISTRY, 2005, 43 (09) : 890 - 899
  • [48] Improved real-time PCR estimation of gene copy number in soil extracts using an artificial reference
    Daniell, T. J.
    Davidson, J.
    Alexander, C. J.
    Caul, S.
    Roberts, D. M.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 91 (01) : 38 - 44
  • [49] Diagnosis of Pelizaeus–Merzbacher disease: detection of proteolipid protein gene copy number by real-time PCR
    Stefano Regis
    Serena Grossi
    Susanna Lualdi
    Roberta Biancheri
    Mirella Filocamo
    Neurogenetics, 2005, 6 : 73 - 78
  • [50] Comparison of multiplex ligation-dependent probe amplification and real-time PCR accuracy for gene copy number quantification using the β-defensin locus
    Perne, Andrea
    Zhang, XiangHong
    Lehmann, Lutz E.
    Groth, Marco
    Stuber, Frank
    Book, Malte
    BIOTECHNIQUES, 2009, 47 (06) : 1023 - 1027