Finite element analysis of locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation

被引:4
|
作者
Yu, Xiao [1 ]
Li, Wei-long [2 ]
Pang, Qing-jiang [1 ]
Zhou, Rong-li [1 ]
机构
[1] Ningbo 2 Hosp, Dept Orthoped, Ningbo, Zhejiang, Peoples R China
[2] Ningbo Univ, Sch Med, Ningbo, Zhejiang, Peoples R China
关键词
Locking plate; 1; 4 tubular plate; tarsometatarsal joint; fracture-dislocation; finite element analysis; BIOMECHANICAL ANALYSIS; ARTHRODESIS; FOOT;
D O I
10.1177/0300060517707114
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective The optimal plate for fixation of tarsometatarsal joint injuries is controversial. The objective of this study was to compare the biomechanical characteristics between a locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation. Method Finite element analysis was used after establishment of a first tarsometatarsal joint fracture-dislocation model. Two implant simulations using a locking plate and five-hole 1/4 tubular plate were designed to simulate fixation of the fracture-dislocation. The displacement of the first tarsometatarsal articular surface and the stress distribution in the implants were calculated. Results A 700-N load was applied to both models. The minimum displacement of the articular surface in the locking plate and 1/4 tubular plate model was 0.6471mm and 0.3833mm, respectively. The maximum principal stress in the locking plate and 1/4 tubular plate was 1.212x10(3)MPa and 1.107x10(3)MPa, respectively. Conclusion Use of a 1/4 tubular plate is recommended for fixation of first tarsometatarsal joint fracture-dislocation after consideration of other factors such as economical issues.
引用
收藏
页码:1528 / 1534
页数:7
相关论文
共 50 条
  • [21] A comparative finite element simulation of locking compression plate materials for tibial fracture treatment
    Beirami, Sami
    Nikkhoo, Mohammad
    Hassani, Kamran
    Karimi, Alireza
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (10) : 1064 - 1072
  • [22] Comparative analysis of mechanical conditions in bone union following first metatarsophalangeal joint arthrodesis with varied locking plate positions: A finite element analysis
    Sabik, Agnieszka
    Daszkiewicz, Karol
    Witkowski, Wojciech
    Luczkiewicz, Piotr
    PLOS ONE, 2024, 19 (05):
  • [23] Dorsal buttress plate fixation for the treatment of fracture-dislocation of the fifth carpometacarpal joint with avulsion fracture of the hamate: a case report
    Iwata, Naoya
    Komura, Shingo
    Hirakawa, Akihiro
    Kanamori, Shigeo
    Masuda, Takahiro
    Ito, Yoshiki
    Akiyama, Haruhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (01) : 135 - 139
  • [24] Comparison of a multidimensional cross locking plate versus a locking compression plate for the treatment of femoral shaft nonunion: Finite element analysis
    Zhang, We
    Hao, Ming
    Chang, Zuhao
    Wu, Yan
    Tang, Peifu
    Chen, Hua
    MEDICAL ENGINEERING & PHYSICS, 2020, 83 : 106 - 111
  • [25] Comparison of a multidimensional cross locking plate versus a locking compression plate for the treatment of femoral shaft nonunion: Finite element analysis
    Zhang, Wei
    Hao, Ming
    Chang, Zuhao
    Wu, Yan
    Tang, Peifu
    Chen, Hua
    Medical Engineering and Physics, 2020, 83 : 106 - 111
  • [26] Finite element stress analysis of a hybrid fracture fixation plate
    Ferguson, SJ
    Wyss, UP
    Pichora, DR
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (03) : 241 - 250
  • [27] A new finite element method for fracture analysis of Reissner plate
    Zhang, JP
    Chen, Q
    Proceedings of the International Conference on Mechanical Engineering and Mechanics 2005, Vols 1 and 2, 2005, : 776 - 778
  • [28] Early Results of Immediate Weightbearing Following First Tarsometatarsal Joint Arthrodesis With Plantar Locking Plate and Dorsal Compression Screw
    Brissey, Nicholas
    Buffington, Adam
    Bush, William
    JOURNAL OF FOOT & ANKLE SURGERY, 2021, 60 (03): : 494 - 500
  • [29] Finite element method analysis of bone stress for variants of locking plate placement
    Palka, Marek
    Miszczyk, Patrycja
    Jurewicz, Maciej
    Perz, Rafal
    HELIYON, 2024, 10 (08)
  • [30] Longitudinally centered embossed structure in the locking compression plate for biodegradable bone implant plate: a finite element analysis
    Chandra, Girish
    Pandey, Ajay
    Tipan, Nilesh
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (06) : 603 - 618