Performance analysis of an automotive heat pump system with desiccant coated heat exchangers

被引:11
|
作者
Na, Sun-Ik [1 ]
Kim, Minsung [2 ]
Kim, Min Soo [3 ]
机构
[1] Korea Inst Energy Res, Thermal Energy Convers Syst Lab, 152 Gajeong ro, Daejeon 34129, South Korea
[2] Chung Ang Univ, Dept Energy Syst Engn, 84 Heukseok ro, Seoul 06974, South Korea
[3] Seoul Natl Univ, Dept Mech Engn, 1 Gwanak ro, Seoul 08826, South Korea
基金
新加坡国家研究基金会;
关键词
Desiccant coated heat exchanger (DCHE); Dehumidification; Heat pump; Electric vehicle (EV); Thermal management system (TMS); METAL-ORGANIC FRAMEWORKS; SILICA-GEL; SURFACE-AREA; ADSORPTION; AIR; SORPTION; MODEL;
D O I
10.1016/j.applthermaleng.2022.118723
中图分类号
O414.1 [热力学];
学科分类号
摘要
Even though an electric vehicle has the advantage of high efficiency, low emission, and more space in the engine room as the combustion engine is not used, it has the disadvantage that consumes the stored energy of the battery a lot for heating and defogging due to the absence of the waste heat from the internal combustion engine. The electric vehicle must operate a heat pump system to heat up the cabin air and to remove the moisture, unlike traditional vehicles. Thereby, the energy consumption of the automotive heat pump should be minimized as much as possible for enhancing the driving mileage to relieve range anxiety. Therefore, the desiccant coated heat exchanger is introduced for dehumidification and waste heat recovery by simultaneous heat and mass transfer. To analyze the energy consumption of the automotive heat pump system, the numerical model, which consists of the cabin thermal load model, the desiccant coated heat exchanger model, and the automotive heat pump model, is made with validation using experimental data. The simulation was conducted to investigate the effect of the desiccant coated heat exchanger on the energy usage of an electric vehicle under various operation conditions. Consequently, the results show that the proposed system requires less energy as compared with the conventional cases.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Analysis on the Performance of Ground Heat Exchangers in Ground Source Heat Pump Systems based on Heat Transfer Enhancements
    Liu, Yong
    Zhang, Yuqiao
    Gong, Shengqiang
    Wang, Zhenfei
    Zhang, Huiting
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 19 - 26
  • [42] Study on heat transfer and dehumidification performance of desiccant coated microchannel heat exchanger
    Wang, Cong
    Ji, Xu
    Yang, Bianfeng
    Zhang, Ren
    Yang, Delong
    Applied Thermal Engineering, 2021, 192
  • [43] Effect of desiccant adsorption isotherm on dehumidification performance of desiccant coated heat exchanger
    Yang T.
    Ge T.
    Huagong Xuebao/CIESC Journal, 2022, 73 (12): : 5367 - 5375
  • [44] Performance evaluation of a desiccant coated heat exchanger with two different desiccant materials
    Erkek, Turkan Ucok
    Gungor, Ali
    Fugmann, Hannes
    Morgenstern, Alexander
    Bongs, Constanze
    APPLIED THERMAL ENGINEERING, 2018, 143 : 701 - 710
  • [45] Analysis of a heat pump with solid desiccant tube bank
    Kiatsiriroat, T
    Tachajapong, W
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (06) : 527 - 542
  • [46] Performance evaluation of an innovative liquid desiccant air-conditioning system directly integrating a heat pump with two membrane energy exchangers
    Elsheniti, Mahmoud Badawy
    Shehata, Ahmed
    Attia, Abd El-Hamid
    El-Maghlany, Wael
    ENERGY CONVERSION AND MANAGEMENT, 2023, 293
  • [47] Performance evaluation of an integrated automotive air conditioning and heat pump system
    Hosoz, M
    Direk, M
    ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (05) : 545 - 559
  • [48] Effects of process air conditions and switching cycle period on dehumidification performance of desiccant-coated heat exchangers
    Chang, Chih-Chang
    Luo, Win-Jet
    Lu, Chi-Wen
    Cheng, Yu-Sheng
    Tsai, Bo-Yi
    Lin, Zhi-Hua
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) : 81 - 90
  • [49] Performance evaluation of MIL-101(Cr) based desiccant-coated heat exchangers for efficient dehumidification
    Ge, Lurong
    Feng, Yaohui
    Wu, Jiarong
    Wang, Ruzhu
    Ge, Tianshu
    ENERGY, 2024, 289
  • [50] Performance analysis of heat pump polygeneration system
    Shaik, Vajeer Baba
    Srinivas, Tangellapalli
    Kukreja, Rajeev
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024,