Deformation vector fields (DVF)-driven image reconstruction for 4D-CBCT

被引:8
|
作者
Dang, Jun [1 ]
Luo, Ouyang [1 ]
Gu, Xuejun [1 ]
Wang, Jing [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75235 USA
关键词
DVF estimation from projection; 4D-CBCT; DVF-driven image reconstruction; CONE-BEAM CT; 3D TUMOR-LOCALIZATION; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; PROJECTION DATA; REAL-TIME; MODEL; REGISTRATION; ALGORITHMS;
D O I
10.3233/XST-140466
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: High quality 4D-CBCT can be obtained by deforming a planning CT (pCT), where the deformation vector fields (DVF) are estimated by matching the forward projections of pCT and 4D-CBCT projections. The matching metric used in the previous study is the sum of squared intensity differences (SSID). The scatter signal level in CBCT projections is much higher than pCT, the SSID metric may not lead to optimal DVF. OBJECTIVE: To improve the DVF estimation accuracy, we develop a new matching metric that is less sensitive to the intensity level difference caused by the scatter signal. METHODS: The negative logarithm of correlation coefficient (NLCC) is used as the matching metric. A non-linear conjugate gradient optimization algorithm is used to estimate the DVF. A 4D NCAT phantom and an anthropomorphic thoracic phantom were used to evaluate the NLCC-based algorithm. RESULTS: In the NCAT phantom study, the relative reconstruction error is reduced from 18.0% in SSID to 14.13% in NLCC. In the thoracic phantom study, the root mean square error of the tumor motion is reduced from 1.16 mm in SSID to 0.43 mm in NLCC. CONCLUSION: NLCC metric can improve the image reconstruction and motion estimation accuracy of DVF-driven image reconstruction for 4D-CBCT.
引用
下载
收藏
页码:11 / 23
页数:13
相关论文
共 50 条
  • [1] Deformation Vector Fields (DVF)-Driven Image Reconstruction for 4D-CBCT
    Dang, J.
    Ouyang, L.
    Gu, X.
    Wang, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Deformation vector fields (DVF)-driven image reconstruction for 4D-CBCT (vol 23, pg 11, 2015)
    Dang, Jun
    Ouyang, Luo
    Gu, Xuejun
    Wang, Jing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (05) : 647 - 647
  • [3] U-net-based deformation vector field estimation for motion-compensated 4D-CBCT reconstruction
    Huang, Xiaokun
    Zhang, You
    Chen, Liyuan
    Wang, Jing
    MEDICAL PHYSICS, 2020, 47 (07) : 3000 - 3012
  • [4] Deformation Vector Field Estimation Using Convolutional Neural Network for Motion-Compensated 4D-CBCT Reconstruction
    Huang, X.
    Chen, L.
    Wang, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E130 - E130
  • [5] Motion Estimation and Spatiotemporal Tensor Enhanced Representation for 4D-CBCT Image Reconstruction
    Liu, Jin
    Kang, Yanqin
    Liu, Guirui
    2020 13TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2020), 2020, : 629 - 634
  • [6] Sliding Motion Compensated Simultaneous 4D-CBCT Reconstruction
    Dang, J.
    Yin, F.
    You, T.
    Dai, C.
    Wang, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3731 - 3731
  • [7] Simultaneous 4D-CBCT reconstruction with sliding motion constraint
    Dang, Jun
    Yin, Fang-Fang
    You, Tao
    Dai, Chunhua
    Chen, Deyu
    Wang, Jing
    MEDICAL PHYSICS, 2016, 43 (10) : 5453 - 5463
  • [8] MODIFIED SIMULTANEOUS MOTION ESTIMATION AND IMAGE RECONSTRUCTION (M-SMEIR) FOR 4D-CBCT
    Zhao, Cong
    Zhong, Yuncheng
    Wang, Jing
    Jin, Mingwu
    2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 340 - 343
  • [9] Biomechanical Modeling Assisted Simultaneous Motion Estimation and Image Reconstruction Incorporating for 4D-CBCT
    Huang, X.
    Zhang, Y.
    Wang, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3285 - 3285
  • [10] Development and Evaluation of a 4D-CBCT Scheme Based On Simultaneous Motion Estimation and Image Reconstruction
    Dang, J.
    Gu, X.
    Ouyang, L.
    Pan, T.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 572 - 572