The aim of this study was to compare 2-dimensional (2D) and 3-dimensional (3D) dynamic PET for the absolute quantification of myocardial blood flow (MBF) with N-13-ammonia (N-13-NH3)Methods: 2D and 3D MBF measurements were collected from 21 patients undergoing cardiac evaluation at rest (n = 14) and during standard adenosine stress (n = 7). A lutetium yttrium oxyorthosilicate-based PET/CT system with retractable septa, enabling the sequential acquisition of 2D and 3D images within the same patient and study, was used. All 2D studies were performed by injecting 700-900 MBq of N-13-NH3. For 14 patients, 3D studies were performed with the same injected N-13-NH3 dose as that used in 2D studies. For the remaining 7 patients, 3D images were acquired with a lower dose of N-13-NH3, that is, 500 MBq. 2D images reconstructed by use of filtered back-projection (FBP) provided the reference standard for MBF measurements. 3D images were reconstructed by use of Fourier rebinning (FORE) with FBP (FORE-FBP), FORE with ordered-subsets expectation maximization (FORE-OSEM), and a reprojection algorithm (RP). Results: Global MBF measurements derived from 3D PET with FORE-FBP (r = 0.97), FORE-OSEM (r = 0.97), and RP (r = 0.97) were well correlated with those derived from 2D FBP (all Ps < 0.0001). The mean +/- SD differences in global MBF measurements between 3D FORE-FBP and 2D FBP and between 3D FORE-OSEM and 2D FBP were 0.01 +/- 0.14 and 0.01 +/- 0.15 mL/min/g, respectively. The mean +/- SD difference in global MBF measurements between 3D RP and 2D FBP was 0.00 +/- 0.16 mL/min/g. The best correlation between 2D PET and 3D PET performed with the lower injected activity was found for the 3D FORE-FBP reconstruction algorithm (r = 0.95,P< 0.001). Conclusion: For this scanner type, quantitative measurements of MBF with 3D PET and N-13-NH3 were in excellent agreement with those obtained with the 2D technique, even when a lower activity was injected.
机构:
Inst Nacl Cardiol Ignacio Chavez, Nucl Cardiol & Cardiac CT, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Alexanderson, Erick
Ochoa, Juan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Ochoa, Juan
Calleja, Rodrigo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Calleja, Rodrigo
Pena, Marco
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Pena, Marco
Romero, Edgar
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Romero, Edgar
Lamothe, Pedro
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Lamothe, Pedro
Martinez, Alfonso
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Martinez, Alfonso
Ceballos, Juan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Ceballos, Juan
Lisker, Andres
论文数: 0引用数: 0
h-index: 0
机构:
Univ Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico
Lisker, Andres
Meave, Aloha
论文数: 0引用数: 0
h-index: 0
机构:
Inst Nacl Cardiol Ignacio Chavez, Nucl Cardiol & Cardiac CT, Mexico City, DF, MexicoUniv Nacl Autonoma Mexico, PET Cyclotron Unit, Mexico City, DF, Mexico