Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET

被引:41
|
作者
Schepis, Tiziano [1 ]
Gaemperli, Oliver [1 ]
Treyer, Valerie [1 ]
Valenta, Ines [1 ]
Burger, Cyrill [1 ]
Koepfli, Pascal [1 ]
Namdar, Mehdi [1 ]
Adachi, Itaru [4 ]
Alkadhi, Hatem [2 ]
Kaufmann, Philipp A. [1 ,3 ]
机构
[1] Univ Zurich Hosp, Ctr Cardiovasc, Clin Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Diagnos Radiol, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Ctr Integrat Human Physiol, CH-8091 Zurich, Switzerland
[4] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 569, Japan
关键词
myocardial blood flow; 3-dimensional PET; N-13-NH3; image reconstruction algorithms;
D O I
10.2967/jnumed.107.044099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare 2-dimensional (2D) and 3-dimensional (3D) dynamic PET for the absolute quantification of myocardial blood flow (MBF) with N-13-ammonia (N-13-NH3)Methods: 2D and 3D MBF measurements were collected from 21 patients undergoing cardiac evaluation at rest (n = 14) and during standard adenosine stress (n = 7). A lutetium yttrium oxyorthosilicate-based PET/CT system with retractable septa, enabling the sequential acquisition of 2D and 3D images within the same patient and study, was used. All 2D studies were performed by injecting 700-900 MBq of N-13-NH3. For 14 patients, 3D studies were performed with the same injected N-13-NH3 dose as that used in 2D studies. For the remaining 7 patients, 3D images were acquired with a lower dose of N-13-NH3, that is, 500 MBq. 2D images reconstructed by use of filtered back-projection (FBP) provided the reference standard for MBF measurements. 3D images were reconstructed by use of Fourier rebinning (FORE) with FBP (FORE-FBP), FORE with ordered-subsets expectation maximization (FORE-OSEM), and a reprojection algorithm (RP). Results: Global MBF measurements derived from 3D PET with FORE-FBP (r = 0.97), FORE-OSEM (r = 0.97), and RP (r = 0.97) were well correlated with those derived from 2D FBP (all Ps < 0.0001). The mean +/- SD differences in global MBF measurements between 3D FORE-FBP and 2D FBP and between 3D FORE-OSEM and 2D FBP were 0.01 +/- 0.14 and 0.01 +/- 0.15 mL/min/g, respectively. The mean +/- SD difference in global MBF measurements between 3D RP and 2D FBP was 0.00 +/- 0.16 mL/min/g. The best correlation between 2D PET and 3D PET performed with the lower injected activity was found for the 3D FORE-FBP reconstruction algorithm (r = 0.95,P< 0.001). Conclusion: For this scanner type, quantitative measurements of MBF with 3D PET and N-13-NH3 were in excellent agreement with those obtained with the 2D technique, even when a lower activity was injected.
引用
收藏
页码:1783 / 1789
页数:7
相关论文
共 50 条
  • [41] Influence of arm positioning on myocardial accumulation and myocardial blood flow in rest and stress 13N-ammonia PET myocardial perfusion imaging
    Kojima, Akihiro
    Ohshima, Satoru
    Tamai, Shin-ichi
    Nishio, Masami
    Tamaki, Tsuneo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [42] Influence of arm positioning on myocardial accumulation and myocardial blood flow in rest and stress 13N-ammonia PET myocardial perfusion imaging
    Kojima, Akihiro
    Ohshima, Satoru
    Tamai, Shin-ichi
    Nishio, Masami
    Tamaki, Tsuneo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [43] Diagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow Reserve
    Fiechter, Michael
    Ghadri, Jelena R.
    Gebhard, Catherine
    Fuchs, Tobias A.
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Herzog, Bernhard A.
    Wyss, Christophe A.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1230 - 1234
  • [44] 13N-ammonia PET/CT stress myocardial blood flow compared to fractional flow reserve in coronary artery disease
    Boer, Jouke J.
    Kappelhof, Johan J. J. S.
    van der Zant, Friso M.
    Wondergem, Maurits
    de Swart, Hans J. B. R. M.
    Knol, Remco J. J.
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (02) : 133 - 138
  • [45] Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?
    dekemp, Robert A.
    Yoshinaga, Keiichiro
    Beanlands, Rob S. B.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (03) : 380 - 397
  • [46] Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?
    Robert A. deKemp
    Keiichiro Yoshinaga
    Rob S. B. Beanlands
    Journal of Nuclear Cardiology, 2007, 14 : 380 - 397
  • [47] Inter-institutional comparison of rest and stress myocardial blood flow by 13N-ammonia and PET in 467 patients
    Sergueeva, TV
    Sayre, JW
    Dahlbom, M
    DiCarli, M
    Heinonen, T
    Hassan, A
    Schelbert, HR
    CIRCULATION, 2002, 106 (19) : 478 - 478
  • [48] Noninvasive assessment of myocardial blood flow, vascular reactivity and atherosclerosis in asymptomatic SLE patients with 13N-ammonia PET
    Alexanderson, Erick
    Ochoa, Juan
    Calleja, Rodrigo
    Pena, Marco
    Romero, Edgar
    Lamothe, Pedro
    Martinez, Alfonso
    Ceballos, Juan
    Lisker, Andres
    Meave, Aloha
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [49] Quantitative analysis of myocardial blood flow response to regadenoson and adenosine using 13N-ammonia perfusion PET.
    Weinberg, Richard
    Castano, Adam
    Panagiotou, Demetrios
    Kinkhabwala, Mona
    Bhatia, Ketan
    Morgenstern, Rachelle
    DeLuca, Albert
    Bokhari, Sabahat
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [50] Erratum to: Characterizing the normal range of myocardial blood flow with 82rubidium and 13N-ammonia PET imaging
    Jennifer M. Renaud
    Jean N. DaSilva
    Rob S. B. Beanlands
    Robert A. deKemp
    Journal of Nuclear Cardiology, 2013, 20 (4) : 702 - 702