Radiation Shielding Study of Advanced Data and Power Management Systems (ADPMS) Housing Using Geant4

被引:0
|
作者
Garcia, F. [1 ]
Kurvinen, K. [1 ]
Brander, T. [2 ]
Orava, R. [1 ]
Heino, J. [1 ]
Virtanen, A. [3 ]
Kettunen, H. [3 ]
Tenhunen, M. [4 ]
机构
[1] Univ Helsinki, Dept Phys Sci, Helsinki Inst Phys, FIN-00014 Helsinki, Finland
[2] Aalto Univ, Lab Lighyweight Struct, FIN-02015 Helsinki, Finland
[3] Univ Jyvaskyla, Dept Phys, FIN-40351 Jyvaskyla, Finland
[4] Helsinki Univ Cent Hosp, FIN-00290 Helsinki, Finland
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The tendency to reduce the spacecraft mass covers nowadays all components of the spacecraft. One potential target is to reduce the mass of electronics and its housings. The use of composite materials, especially CFRP is a well known and vastly used approach to mass reduction. In cost reduction the use of standard (non-space qualified) electronics has increased. These commercial circuits and other components cannot tolerate as high radiation levels as space qualified components. Therefore the use of standard electronics components poses challenge in terms of the radiation protection capability of the ADPMS housings. The main goal of this study is to give an insight on the radiation shielding protection produced by different configurations of CFRP wolfram laminates of epoxies and cyanate esters and then to compare them to the protection given by the commonly used laminates of aluminium. For a spacecraft operating in LEO and MEO orbits the main components of the space radiation environment are energetic electrons and protons, therefore in our study we will compare the experimental and simulation results of the radiation attenuation of different types of laminates for those particles. At the same time the experimental data has been used to validate the Geant4 model of the laminates, which can be used for future optimizations of the laminate structures.
引用
收藏
页码:1609 / 1613
页数:5
相关论文
共 50 条
  • [31] Simulation study for a single TOF scintillator using GEANT4
    Zhang, LM
    Peng, HP
    Zhang, ZP
    Chen, HF
    Shao, M
    Wu, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (07) : N54 - N57
  • [32] Characterization of intrinsic radiation in LYSO scintillators using GEANT4 and SimSiPM simulations
    Kolcu, O. B.
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [33] Calculation Of Self-Shielding Factor for Neutron Activation Experiments Using GEANT4 And MCNP
    Romero-Barrientos, Jaime
    Molina, F.
    Aguilera, Pablo
    Arellano, H. F.
    LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2016, 1753
  • [34] Gamma-ray shielding parameters of lithium borotellurite glasses using Geant4 code
    Kebaili, Imen
    Sayyed, M., I
    Boukhris, Imed
    Al-Buriahi, M. S.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (07):
  • [35] Command-Based Interface of Importance Biasing Technique Using Geant4 for Shielding Applications
    Oyama, Syouhei
    Aso, Tsukasa
    Shimaoka, Mitsuyoshi
    Amako, Katsuya
    Yoshida, Hajime
    Sasaki, Takashi
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [36] Application of automated weight windows to spallation neutron source shielding calculations using Geant4
    Stenander, John
    DiJulio, Douglas D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 798 : 167 - 171
  • [37] Gamma-ray shielding parameters of lithium borotellurite glasses using Geant4 code
    Imen Kebaili
    M. I. Sayyed
    Imed Boukhris
    M. S. Al-Buriahi
    Applied Physics A, 2020, 126
  • [38] An extensive study of depth dose distribution and projectile fragmentation cross-section for shielding materials using Geant4
    Sangwan, Nitika
    Kumar, Ashavani
    APPLIED RADIATION AND ISOTOPES, 2022, 180
  • [39] Assessment of the power deposition on the MEGAPIE spallation target using the GEANT4 toolkit
    Lamrabet, Abdesslam
    Maghnouj, Abdelmajid
    Tajmouati, Jaouad
    Bencheikh, Mohamed
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (04)
  • [40] Radiation shielding study of WO3-ZnO-PbO-B2O3 glasses using Geant4 and Phys-X: A comparative study
    Al-Hadeethi, Y.
    Sayyed, M., I
    Nune, Manasa
    CERAMICS INTERNATIONAL, 2021, 47 (03) : 3988 - 3993