Digital Image Correlation: A Novel Dynamic Three-Dimensional Imaging Technique for Precise Quantification of the Dynamic Rhytid and Botulinum Toxin Type A Efficacy

被引:12
|
作者
Wilson, Anthony J. [1 ]
Chin, Bianca C. [1 ]
Hsu, Vivian M. [1 ]
Mirzabeigi, Michael N. [1 ]
Percec, Ivona [1 ]
机构
[1] Univ Penn, Div Plast Surg, Philadelphia, PA 19104 USA
关键词
GLABELLAR FROWN LINES; FACIAL MOVEMENT; DOUBLE-BLIND; QUANTITATIVE-ANALYSIS; INCOBOTULINUMTOXINA; FACE;
D O I
10.1097/PRS.0000000000001224
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Quantification of facial dynamic motion is paramount for improving cosmetic and reconstructive surgical outcomes. The authors introduce digital image correlation using speckle tracking photogrammetry and ARAMIS software (GOM mbH, Braunschweig, Germany) to study facial dynamics and demonstrate its application in quantifying botulinum toxin efficacy. Methods: Fourteen subjects were evaluated using a dual camera system and three-dimensional optical analysis. Using ARAMIS software, the anatomic regions of the glabella, forehead, and total face were identified and highlighted. Tissue strain, defined as either compression or stretch, was measured within these regions over 36 frames during brow furrowing. Each patient was measured before and 2 weeks after injection of 20 units of onabotulinumtoxinA in the glabella. Average stretch and compression in treated areas were analyzed across all available frames. Results were compared using a Wilcoxon signed rank test. Results: After neurotoxin injection, average vertical stretch of the glabella during brow furrowing decreased from 2.51 percent to 1.15 percent (p < 0.05), and average vertical stretch in the forehead decreased from 6.73 percent to 1.67 percent (p < 0.05). Horizontal compression in the glabella decreased from 9.11 percent to 2.60 percent (p < 0.05) and from 4.83 percent to 0.83 percent (p < 0.05) in the forehead. Total facial major strain decreased from 4.41 percent to 3.05 percent (p < 0.05), and total facial minor strain decreased from 5.01 percent to 3.51 percent (p < 0.05). Conclusions: The authors introduce digital image correlation as a novel technology for measuring dynamic rhytid and neurotoxin efficacy. This technique allows for advancements in the study of dynamic aging and neuromuscular disorders.
引用
收藏
页码:869E / 876E
页数:8
相关论文
共 50 条
  • [31] A novel three-dimensional dynamic anorectal ultrasonography technique for the assessment of perineal descent, compared with defaecography
    Murad-Regadas, S. M.
    dos Santos, D.
    Soares, G.
    Regadas, F. S. P.
    Rodrigues, L. V.
    Buchen, G.
    Kenmoti, V. T.
    Surima, W. S.
    Fernandes, G. O. da S.
    COLORECTAL DISEASE, 2012, 14 (06) : 740 - 747
  • [32] A novel two-dimensional dynamic anal ultrasonography technique to assess anismus comparing with three-dimensional echodefecography
    Murad-Regadas, S. M.
    Regadas, F. S. P.
    Barreto, R. G. L.
    Rodrigues, L. V.
    de Souza, M. H. L. P.
    COLORECTAL DISEASE, 2009, 11 (08) : 872 - 877
  • [33] Single-Camera Digital-Image Correlation Three-Dimensional Panoramic Measurement Using Reflector Imaging
    Ge Pengxiang
    Wang Huanqing
    Zhu Yilei
    Wang Yonghong
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (09):
  • [34] A novel three-dimensional dynamic anorectal ultrasonography technique (echodefecography) to assess obstructed defecation, a comparison with defecography
    Murad-Regadas, Sthela M.
    Regadas, F. Sergio P.
    Rodrigues, Lusmar V.
    Silva, Flavio R.
    Soares, Fabio A.
    Escalante, Rodrigo D.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (04): : 974 - 979
  • [35] A novel three-dimensional dynamic anorectal ultrasonography technique (echodefecography) to assess obstructed defecation, a comparison with defecography
    Sthela M. Murad-Regadas
    F. Sérgio P. Regadas
    Lusmar V. Rodrigues
    Flavio R. Silva
    Fabio A. Soares
    Rodrigo D. Escalante
    Surgical Endoscopy, 2008, 22 : 974 - 979
  • [36] A new dynamic three-dimensional digital color Doppler method for quantification of pulmonary regurgitation: Validation study in an animal model
    Mori, Y
    Rusk, RA
    Jones, M
    Li, XN
    Irvine, T
    Zetts, AD
    Sahn, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (06) : 1179 - 1185
  • [37] Full-field measurement and fracture characterisations of rocks under dynamic loads using high-speed three-dimensional digital image correlation
    Xing, H. Z.
    Zhang, Q. B.
    Ruan, D.
    Dehkhoda, S.
    Lu, G. X.
    Zhao, J.
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2018, 113 : 61 - 72
  • [38] Single-Camera Three-Dimensional Digital Image Correlation with Enhanced Accuracy Based on Four-View Imaging
    Shao, Xinxing
    Qu, Jingye
    Chen, Wenwu
    MATERIALS, 2023, 16 (07)
  • [39] A novel three-dimensional MRI-CT image fusion technique for precise preoperative evaluation and treatment of capitellar osteochondritis dissecans
    Kohyama, Sho
    Nishiura, Yasumasa
    Hara, Yuki
    Ogawa, Takeshi
    Ikumi, Akira
    Okano, Eriko
    Totoki, Yasukazu
    Yamazaki, Masashi
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 5721 - 5733
  • [40] A novel three-dimensional MRI-CT image fusion technique for precise preoperative evaluation and treatment of capitellar osteochondritis dissecans
    Sho Kohyama
    Yasumasa Nishiura
    Yuki Hara
    Takeshi Ogawa
    Akira Ikumi
    Eriko Okano
    Yasukazu Totoki
    Masashi Yamazaki
    European Radiology, 2021, 31 : 5721 - 5733