Assessment of blood flow distal to coronary artery stenoses - Correlations between myocardial positron emission tomography and poststenotic intracoronary Doppler flow reserve

被引:51
|
作者
Miller, DD [1 ]
Donohue, TJ [1 ]
Wolford, TL [1 ]
Kern, MJ [1 ]
Bergmann, SR [1 ]
Cauley, MB [1 ]
Mechem, CM [1 ]
Hartman, JJ [1 ]
机构
[1] WASHINGTON UNIV, SCH MED, ST LOUIS, MO USA
关键词
blood flow; tomography; coronary disease; perfusion;
D O I
10.1161/01.CIR.94.10.2447
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Previous studies have correlated quantitative coronary angiographic stenosis severity with positron emission tomography (PET) myocardial perfusion and proximal measurements of intracoronary flow velocities in normal and diseased coronary arteries. The aim of this study was to correlate regional myocardial blood flow (RMBF) derived from [O-15]H2O PET with directly measured poststenotic intracoronary Doppler flow velocity data acquired under basal conditions and dipyridamole-induced hyperemia. Methods and Results Eleven consecutive patients 53+/-13 years old with ischemic chest pain and isolated proximal left coronary artery stenoses (left anterior descending, 9; left circumflex, 2; mean, 59+/-23% diameter stenosis) underwent [O-15]H2O myocardial PET and intracoronary Doppler flow velocity studies within 1 week. PET RMBF (mL . g(-1). min(-1)) and myocardial perfusion reserve (MPR) were calculated in poststenotic and normal reference vascular beds. Poststenotic Doppler average peak flow velocities (APV; cm/s) and coronary flow velocity reserve (CFR) were compared with corresponding PET data and quantitative angiographic lesional parameters. PET RMBF and Doppler APV were linearly correlated (r=.60;P<.001), as were poststenotic PET MPR and Doppler CFR (r=.76; P<.0002). Relative coronary flow velocity and MPR ratios between poststenotic and angiographically normal vascular beds were comparably reduced (0.83+/-0.25 versus 0.86+/-0.21, respectively; P=NS). Conclusions Intracoronary Doppler flow velocities acquired distal to isolated left coronary artery stenoses correlated with [O-15]H2O PET regional myocardial perfusion and are useful for assessment of the physiological significance of coronary stenoses in humans.
引用
收藏
页码:2447 / 2454
页数:8
相关论文
共 50 条
  • [41] Decreased coronary flow reserve in an obese cohort determined by positron emission tomography myocardial perfusion imaging
    Vitarius, JA
    Youssef, IM
    Travis, AR
    Chatterjee, S
    Machac, J
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2005, 25 (05) : E103 - E103
  • [42] Comparison between contrast enhanced magnetic resonance imaging and positron emission tomography for the assessment of myocardial flow reserve.
    Nekolla, SG
    Ibrahim, T
    Schreiber, K
    Bülow, H
    Mehilli, J
    Schwaiger, M
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 9P - 9P
  • [43] Myocardial blood flow and flow reserve in coronary artery disease: Value and challenges
    Alluri, Krishna Chaitanya
    Tahari, Abdel
    Rajaram, Mahadevan
    Subramaniam, Rathan
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [44] Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease
    Gewirtz, Henry
    Dilsizian, Vasken
    CIRCULATION, 2016, 133 (22) : 2180 - 2196
  • [45] Good agreement between functional assessment by stress echocardiography and coronary flow reserve measured by intracoronary Doppler
    Duffy, SJ
    Gelman, JS
    Peverill, RE
    Greentree, MA
    Dowling, RA
    Harper, RW
    Meredith, IT
    CIRCULATION, 1998, 98 (17) : 709 - 709
  • [46] Relative coronary flow velocity reserve improves correlation with stress myocardial perfusion imaging in assessment of coronary artery stenoses
    Voudris, V
    Avramides, D
    Koutelou, M
    Malakos, J
    Manginas, A
    Papadakis, M
    Cokkinos, DV
    CHEST, 2003, 124 (04) : 1266 - 1274
  • [47] Assessment of coronary flow reserve:: Comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography
    Ibrahim, T
    Nekolla, SG
    Schreiber, K
    Odaka, K
    Volz, S
    Mehilli, J
    Güthlin, M
    Delius, W
    Schwaiger, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 864 - 870
  • [48] Comparison of Diagnostic Performance of Relative Flow Reserve With Coronary Flow Reserve By 13N-ammonia Positron Emission Tomography to Detect Coronary Artery Disease
    Kiko, Takatoyo
    Takeishi, Yasuchika
    CIRCULATION, 2019, 140
  • [49] COMPARISON OF STENOTIC FLOW RESERVE BY QUANTITATIVE CORONARY ANGIOGRAPHY WITH INTRACORONARY DOPPLER FLOW RESERVE AND MYOCARDIAL TL-201 SCINTIGRAPHY
    MOERTL, D
    PORENTA, G
    BINDER, T
    SOCHOR, H
    PROBST, P
    CIRCULATION, 1995, 92 (08) : 1248 - 1248
  • [50] The detection of multivessel coronary artery disease: the value of SPECT CZT myocardial blood flow and coronary flow reserve assessment
    Zavadovsky, K.
    Mochula, A.
    Maltseva, A.
    Baev, A.
    Andreev, S.
    Liga, R.
    Gimelli, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S329 - S329