Beam hardening correction method forturbine blades CT imaging

被引:0
|
作者
Zhang Lei [1 ]
Fu Jian [1 ]
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Beijing 100083, Peoples R China
来源
ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS | 2007年
关键词
industrial X-ray computed tomography; reprojection; beam hardening correction; turbine blades;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Because of beam hardening, images from a polychromatic industrial X-ray computed tomography (ICT) system are led to cupping and streak artifacts, when turbine blades are tested. In conventional polynomial fitting correction technique, it needs stepladder phantom to establish the beam hardening correction model, so it affects the practicability of this technique. To overcome this affect, a beam hardening correction method using polynomial fit based on reprojection was researched The method segmented the original CT image into different sections and reprojected the image to obtain the thickness set of X-ray penetrating specimen, fitted the relationship between the thickness and the polychromatic projection data by polynomial to establish the beam gardening correction model to calibrate the raw projection data. Research shows this method can eliminate beam hardening effectively and CT imaging quality is conspicuously improved, especially for the key cross-sections of turbine blades.
引用
收藏
页码:4188 / 4191
页数:4
相关论文
共 50 条
  • [21] Simultaneous correction of bone and contrast beam hardening artifacts in CT
    Ruth, C
    Joseph, PM
    RADIOLOGY, 1996, 201 : 1065 - 1065
  • [22] Simplified Beam Hardening Correction for Ultrafast X-ray CT Imaging of Binary Granular Mixtures
    Bieberle, Martina
    Papapetrou, Theodoros Nestor
    Lecrivain, Gregory
    Windisch, Dominic
    Bieberle, Andre
    Wagner, Michael
    Hampel, Uwe
    SENSORS, 2024, 24 (10)
  • [23] A beam hardening correction method based on HL Consistency
    Mou, Xuanqin
    Tang, Shaojie
    Yu, Hengyong
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [24] A novel beam hardening correction method for computed tomography
    Li, Baolei
    Zhang, Quanhong
    Li, Junjiang
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 891 - 895
  • [25] A Method for Simultaneous Image Reconstruction and Beam Hardening Correction
    Jin, Pengchong
    Bouman, Charles A.
    Sauer, Ken D.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [26] TOWARDS BEAM HARDENING CORRECTION FOR POLYCHROMATIC X-RAY CT
    Park, Hyoung Suk
    Gao, Hao
    Lee, Sung Min
    Seo, Jin Keun
    JOURNAL OF COMPUTATIONAL MATHEMATICS, 2016, 34 (06) : 671 - 682
  • [27] Quantitative evaluation of beam-hardening artefact correction in dual-energy CT myocardial perfusion imaging
    Bucher, Andreas M.
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Wolla, Christopher D.
    Canstein, Christian
    McQuiston, Andrew D.
    Krazinski, Aleksander W.
    De Cecco, Carlo N.
    Meinel, Felix G.
    Vogl, Thomas J.
    Geyer, Lucas L.
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3215 - 3222
  • [28] CT IMAGE CORRECTION FOR BEAM HARDENING USING SIMULATED PROJECTION DATA
    MEAGHER, JM
    MOTE, CD
    SKINNER, HB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (04) : 1520 - 1524
  • [29] Beam hardening artifact correction in CT based on re-projection
    Wu, Zhi-Hong
    Cong, Peng
    Liu, Xi-Ming
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (05): : 935 - 938
  • [30] An image-based beam hardening correction technique for CT images
    Raupach, R
    Stierstorfer, K
    Flohr, TG
    Fischbach, RM
    Freund, M
    Tomandl, BF
    RADIOLOGY, 2001, 221 : 544 - 544