High-performance liquid chromatographic determination of cefepime in human plasma and in urine and dialysis fluid using a column-switching technique

被引:34
|
作者
Cherti, N
Kinowski, JM
Lefrant, JY
Bressolle, F
机构
[1] Univ Montpellier 1, Clin Pharmacokinet Lab, Montpellier, France
[2] Caremeau Hosp, Serv Pharm, Pharmacokinet Lab, Nimes, France
[3] Fac Pharm Montpellier, Federat Anesthesiol Intens Care & Emergency, F-34060 Montpellier 2, France
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 754卷 / 02期
关键词
cefepime;
D O I
10.1016/S0378-4347(00)00630-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatographic method with UV absorbance was developed for the analysis of cefepime in human plasma and urine, and in dialysis fluid. Detection was performed at 280 nm. The assay procedure for cefepime in plasma involves the addition of an internal standard (cefpirome) followed by treatment of the samples with trichloracetic acid, acetonitrile and dichloromethane. To quantify cefepime in diluted urine (1:20) and in the dialysis fluid, samples spiked with the internal standard (cefpirome) were analysed using a column-switching technique. The HPLC column, Nucleosil C-18, was equilibrated with an eluent mixture composed of acetonitrile-ammonium acetate (pH 4). Linear detector responses were observed for the calibration curve standards in the range 0.5 to 100 mug/ml, which spans what is currently thought to be the clinically relevant range for cefepime concentrations in body fluids. The limit of quantification was 0.5 mug/ml in the three matrices. Extraction recoveries proved to be more than 84%. Precision, expressed as %RSD, was in the range 1.5 to 9%. Accuracy ranged from 93 to 105%. This method was used to follow the time course of the concentration of cefepime in plasma, urine and dialysate outlet samples after a 10-min infusion period of 2 g of this drug in patients with acute renal failure undergoing hemodiafiltration. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:377 / 386
页数:10
相关论文
共 50 条
  • [11] Column-switching high-performance liquid chromatographic method for the determination of zaltoprofen in rat plasma
    Choi, SO
    Um, SY
    Jung, SH
    Jung, SJ
    Kim, JI
    Lee, HJ
    Chung, SY
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 301 - 305
  • [12] DETERMINATION OF OXIRACETAM IN PLASMA AND URINE BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LECAILLON, JB
    SOUPPART, C
    LEDUIGOU, F
    DUBOIS, JP
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 : 223 - 230
  • [13] Column-switching high-performance liquid chromatographic assay for the determination of quercetin in human urine with ultraviolet absorbance detection
    Nielsen, SE
    Dragsted, LO
    JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2): : 81 - 89
  • [14] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROXYLYSYLPYRIDINOLINE AND LYSYLPYRIDINOLINE IN URINE USING A COLUMN-SWITCHING METHOD
    YOSHIMURA, Y
    OHNISHI, K
    HAMAMURA, M
    ODA, T
    SOHDA, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01): : 43 - 49
  • [15] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF NEDOCROMIL SODIUM IN HUMAN URINE USING BIMODAL COLUMN-SWITCHING
    BAKER, PR
    GARDNER, JJ
    WILKINSON, D
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 668 (01): : 59 - 65
  • [16] SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CHLORPHENIRAMINE IN HUMAN SERUM USING COLUMN-SWITCHING
    YAMAGUCHI, M
    MONJI, H
    YAMASHITA, K
    AOKI, I
    YASHIKI, T
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (01): : 168 - 172
  • [17] COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC (HPLC) DETERMINATION OF HYDROCHLOROTHIAZIDE IN RAT, DOG, AND HUMAN PLASMA
    KUO, BS
    MANDAGERE, A
    OSBORNE, DR
    HWANG, KK
    PHARMACEUTICAL RESEARCH, 1990, 7 (12) : 1257 - 1261
  • [18] Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection
    Nielsen, SE
    Dragsted, LO
    JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02): : 379 - 386
  • [19] ROUTINE DETERMINATION OF HYDROXYPHENYTOIN IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AN AUTOMATIC COLUMN-SWITCHING TECHNIQUE
    JURGENS, U
    JOURNAL OF CHROMATOGRAPHY, 1983, 275 (02): : 335 - 343
  • [20] COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF VANCOMYCIN IN SERUM
    DEMOTESMAINARD, F
    LABAT, L
    VINCON, G
    BANNWARTH, B
    THERAPEUTIC DRUG MONITORING, 1994, 16 (03) : 293 - 297