Hollow-fibre liquid-phase microextraction and gas chromatography-mass spectrometric determination of amphetamines in whole blood

被引:21
|
作者
Bombana, Henrique Silva [1 ]
dos Santos, Marcelo Filonzi [1 ]
Munoz, Daniel Romero [1 ]
Leyton, Vilma [1 ]
机构
[1] Univ Sao Paulo, Fac Med, Av Dr Arnaldo,455 Cerqueira Cesar, BR-01246903 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Amphetamines; Liquid-phase microextraction; Green chemistry; STIMULANTS; HAIR; METHAMPHETAMINE; METABOLITES; COCAINE; URINE; DRUGS; MDMA;
D O I
10.1016/j.jchromb.2020.121973
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here, we present a fully validated method using a hollow-fibre liquid-phase microextraction technique for the determination by gas chromatography-mass spectrometry (GC-MS) of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxyethylamphetamine (MDEA) in whole blood. The validation parameters presented successful values within those recommended by the Scientific Working Group for Forensic Toxicology (SWGTox) in the Standard Practices for Method Validation in Forensic Toxicology. The limits of detection ranged from 1 to 3 ng/mL, and the limits of quantification ranged from 2 to 5 ng/mL. The determination coefficients (r(2)) ranged from 0.990 to 0.997, and the method presented good intraday and interday accuracy (from 90.4% to 97.2%) and satisfactory recovery (from 68% to 110%). No carryover was observed. The heteroscedasticity was tested, and only AMP presented homoscedasticity. Weighting factors were applied to correct the linearity of MET (1/x(2)), MDA (1/x), FEN (1/x(1/2)), MDMA (1/x(2)) and MDEA (1/y). Dilution integrity was tested at ratios of 1:2, 1:5 and 1:10, and all maintained intraday precision (from 94.9% to 99.3%) and interday precision (from 89.4% to 94.9%). The validated method was applied to six real whole blood samples from individuals suspected of consuming ecstasy, and MDMA, MDA and amphetamine were successfully identified and quantified.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Determination of estrogenic compounds in milk and yogurt samples by hollow-fibre liquid-phase microextraction-gas chromatography-triple quadrupole mass spectrometry
    Giovanni D’Orazio
    Javier Hernández-Borges
    Antonio Vicente Herrera-Herrera
    Salvatore Fanali
    Miguel Ángel Rodríguez-Delgado
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7447 - 7459
  • [12] Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma
    Basheer, C
    Lee, HK
    Obbard, JP
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) : 161 - 169
  • [13] Analysis of oestrogenic compounds in dairy products by hollow-fibre liquid-phase microextraction coupled to liquid chromatography
    Socas-Rodriguez, Barbara
    Asensio-Ramos, Maria
    Hernandez-Borges, Javier
    Angel Rodriguez-Delgado, Miguel
    FOOD CHEMISTRY, 2014, 149 : 319 - 325
  • [14] Hollow-fibre liquid-phase microextraction of phthalate esters from water
    Psillakis, E
    Kalogerakis, N
    JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) : 145 - 153
  • [15] Hollow fibre-based liquid-phase microextraction technique combined with gas chromatography-mass spectrometry for the determination of pyrethroid insecticides in water samples
    San Roman, I.
    Alonso, M. L.
    Bartolome, L.
    Alonso, R. M.
    TALANTA, 2012, 100 : 246 - 253
  • [16] Determination of polychlorinated biphenyls in water using dynamic hollow fiber liquid-phase microextraction and gas chromatography-mass spectrometry
    Li, Guanhua
    Zhang, Lijun
    Zhang, Zhanen
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (01) : 119 - 122
  • [17] Investigation of bioaccumulation profile of oestrogens in zebrafish liver by hollow fibre protected liquid phase microextraction with gas chromatography-mass spectrometric detection
    Kanimozhi, Sivarajan
    Basheer, Chanbasha
    Neveliappan, Shanmugam
    Ang, Kelvin
    Xue, Feng
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 909 : 37 - 41
  • [18] Hollow-Fibre Liquid-Phase Microextraction in the Three-Phase Mode - Practical Considerations
    Gjelstad, Astrid
    Taherkhani, Hamidreza
    Rasmussen, Knut Einar
    Pederson-Bjergaard, Stig
    Majors, Ronald E.
    LC GC EUROPE, 2011, 24 (12) : 633 - +
  • [19] Determination of Pyrethroids in Soil by Hollow Fiber-based Liquid-Phase Microextraction and Chromatography-Mass Spectrometry
    Shao Yan
    Zhang Li-Jun
    Zhang Zhan-En
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (11) : 1753 - 1757
  • [20] Application of Liquid-Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Determination of Chloroform in Drinking Water
    Ru-song Zhao
    Chuan-ge Cheng
    Jin-peng Yuan
    Ting Jiang
    Lei Li
    Xiao-bai Xu
    Analytical Sciences, 2006, 22 : 563 - 566