A 3-to 18-Year Follow-Up of Revision Total Hip Arthroplasty With Impacted Bone Allografts and Cemented Lubinus SP II Stem. Clinical, Radiographic, and Survivorship Analysis With Comparison to the Literature

被引:7
|
作者
Stigbrand, Hampus [1 ,2 ]
Ullmark, Gosta [1 ,2 ]
机构
[1] Lanssjukhuset, Dept Orthopaed Surg, S-80187 Gavle, Sweden
[2] Uppsala Univ, Ctr Res & Dev, Cty Council Gavleborg, Uppsala, Sweden
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 09期
关键词
total hip arthroplasty; impaction bone grafting; revision; cement; clinical; follow-up; MODULAR FEMORAL STEMS; DRIED IRRADIATED BONE; PROSPECTIVE COHORT; SHEAR-STRENGTH; EXETER STEM; SUBSIDENCE; COMPONENT; SURGERY; COMPLICATIONS; REPLACEMENT;
D O I
10.1016/j.arth.2017.04.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We present the first medium- to long-term follow-up of revision total hip arthroplasty using impaction bone grafting (IBG) combined with the matte and collared Lubinus SP II stem for cases of severe osteolysis and stem loosening. Methods: Sixty-nine femoral revisions were identified for 67 patients consecutively operated with revision femoral arthroplasty using IBG and a cemented Lubinus SP II stem. The mean age was 69 years (standard deviation, 9.9). We retrospectively analyzed 68 cases (1 was lost to follow-up). At the time of the revision surgery, all had substantial femoral bone loss. Fifteen of the revisions were performed due to deep infection. The patients were analyzed by clinical score and radiography. Results: At follow-up, 4 femoral components (6%) had been rerevised or assessed as failure. Of these 4, 3 were assessed as mechanical failure, and 1 for dislocation; none was for infection. Three cups (4%) had been revised for dislocation; 1 of these also had a stem exchange. Three cases (4%) had been reoperated for a periprosthetic fracture in distal femur without stem exchange. Radiologic results were excellent and the clinical Merle d'Aubigne-Postel score had improved from a mean of 12.2 preoperatively to 17.5 at follow-up. Conclusion: IBG combined with the Lubinus SP II stem is safe and results in a low rate of periprosthetic fractures and dislocations. The medium-to long-term clinical result was excellent, with regeneration of living bone in the femur. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:2810 / 2814
页数:5
相关论文
共 43 条
  • [41] Pre-operative bone mineral density is a predictive factor for excellent early patient-reported outcome measures in cementless total hip arthroplasty using a proximally fixed anatomic stem. A prospective study at two year minimum follow-up: several questions
    Chen, Ziyuan
    Jin, Ling
    Wang, Wanchun
    Zhou, Jian
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (05) : 1383 - 1384
  • [42] Cohort analysis of two thousand nine hundred forty-three Link Lubinus SP II cemented total hip arthroplasties from a single hospital with surgeon stratification and twenty six thousand, nine hundred and eighty one component-years of follow-up
    Kropivsek, Luka
    Roskar, Samo
    Zore, Lenart Andrej
    Antolic, Vane
    Mavcic, Blaz
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (04) : 797 - 804
  • [43] Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up
    Rashid, Mustafa S.
    Cunningham, Lindsay
    Shields, David W.
    Walton, Michael J.
    Monga, Puneet
    Bale, Richard S.
    Trail, Ian A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (10) : 2017 - 2026