Cooling performance analysis of nanofluid assisted novel photovoltaic thermoelectric air conditioner for energy efficient buildings

被引:22
|
作者
Bakthavatchalam, Balaji [1 ,2 ]
Habib, Khairul [1 ]
Saidur, R. [3 ,4 ]
Saha, Bidyut Baran [5 ]
机构
[1] Univ Teknol PETRONAS, Dept Mech Engn, Seri Iskandar 32610, Perak, Malaysia
[2] Amrita Sch Engn, Dept Mech Engn, Chennai, India
[3] Sunway Univ, Res Ctr Nanomat & Energy Technol RCNMET, Sch Engn & Technol, Subang Jaya, Malaysia
[4] Univ Lancaster, Dept Engn, Lancaster LA1 4YW, England
[5] Kyushu Univ, Int Inst Carbon Neutral Energy Res, 744 Motooka Nishi Ku, Fukuoka, Fukuoka 8190395, Japan
关键词
Nanofluid assisted thermoelectric air conditioner (NTEAC); Photovoltaic; Nanofluid; Coefficient of performance; Energy saving; CO2; emission; LIFE-CYCLE ASSESSMENT; SYSTEM; DEVICES; UNIT;
D O I
10.1016/j.applthermaleng.2022.118691
中图分类号
O414.1 [热力学];
学科分类号
摘要
Carbon emissions and excessive power usage are addressed by applying thermoelectric cooling, which benefits from its ability to be portable, economical, and reliable. However, a conventional thermoelectric air conditioner's coefficient of performance (COP) is much less due to the sustained heat generated on the thermoelectric module's hot side. This work presents a novel idea of utilizing a nanofluid cooled radiator as an external cooling jacket around the thermoelectric module's hot side to enhance the heat transfer rate of thermoelectric air conditioners. In this research, the performance of a newly designed thermoelectric air conditioner (TEAC) powered by photovoltaic systems (PV) installed in a residential building is analyzed using nanofluid as a coolant. Furthermore, by supplying different input currents (2-6A), the cooling characteristics and performance of the newly designed nanofluid assisted thermoelectric air conditioner (NTEAC) system were experimentally studied in a test room of 25.6 m(3) volume in Malaysia's tropical climate. The system's best performance was at 6A, with a maximum temperature drop of 4.9 degrees C, a cooling capacity of 571 W, and a coefficient of performance of 1.27. In addition, the NTEAC system showed an energy saving of 67% and CO2 emission mitigation of 76% when compared with a conventional split air conditioner. Thus, an alternative to the traditional air conditioning system was developed from this research, which is Freon free. This system is expected to consume less energy and emit less CO2 for the tropical climatic conditions.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Performance simulation and applicability analysis of hybrid air conditioner in cooling season
    Yang, Zixu
    Xiao, Hansong
    Wang, Baolong
    Zhang, Youlin
    Cui, Mengdi
    Huang, Boliang
    Zhao, Jiaan
    Shi, Wenxing
    BUILDING AND ENVIRONMENT, 2022, 210
  • [22] Energy saving in buildings by using the exhaust and ventilation air for cooling of photovoltaic panels
    Shahsavar, A.
    Salmanzadeh, M.
    Ameri, M.
    Talebizadeh, P.
    ENERGY AND BUILDINGS, 2011, 43 (09) : 2219 - 2226
  • [23] Photovoltaic Thermal Management by Combined Utilization of Thermoelectric Generator and Power-Law-Nanofluid-Assisted Cooling Channel
    Selimefendigil, Fatih
    Okulu, Damla
    Öztop, Hakan F.
    SUSTAINABILITY, 2023, 15 (06)
  • [24] Study of a thermoelectric air duct system assisted by photovoltaic wall for space cooling in tropical climate
    Irshad, Kashif
    Habib, Khairul
    Basrawi, Firdaus
    Saha, Bidyut Baran
    ENERGY, 2017, 119 : 504 - 522
  • [25] Performance analysis on a novel sorption air conditioner for electric vehicles
    Jiang, L.
    Wang, R. Z.
    Li, J. B.
    Wang, L. W.
    Roskilly, A. P.
    ENERGY CONVERSION AND MANAGEMENT, 2018, 156 : 515 - 524
  • [26] Analysis of the Performance of a Solar Thermoelectric Generator for Variable Leg Geometry with Nanofluid Cooling
    Ramos-Castaneda, Cristian Francisco
    Olivares-Robles, Miguel Angel
    Mendez-Mendez, Juan Vicente
    PROCESSES, 2021, 9 (08)
  • [27] Energy and performance analysis of solar solid desiccant cooling systems for energy efficient buildings in tropical regions
    Dezfouli, M. M. S.
    Sopian, K.
    Kadir, Kushsairy
    ENERGY CONVERSION AND MANAGEMENT-X, 2022, 14
  • [28] Experimental study and performance analysis of a solar thermoelectric air conditioner with hot water supply
    Liu, Zhong Bing
    Zhang, Ling
    Gong, GuangCai
    Luo, YongQiang
    Meng, FangFang
    ENERGY AND BUILDINGS, 2015, 86 : 619 - 625
  • [29] Environmental and energy analysis for photovoltaic-thermoelectric solar unit in existence of nanofluid cooling reporting CO2 emission reduction
    Sheikholeslami, M.
    Khalili, Z.
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2024, 156
  • [30] OPTIMAL PERFORMANCE OF AIR/AIR THERMOELECTRIC HEAT PUMP (THP) COUPLED TO ENERGY-EFFICIENT BUILDINGS COUPLING IN DIFFERENT CLIMATE CONDITIONS
    Kim, Y. W.
    Ramousse, J.
    Fraisse, G.
    Dalicieux, P.
    Baranek, P.
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 1110 - 1116