Transport measurements at low temperatures in a diamond anvil cell with helium as pressure medium

被引:24
|
作者
Thomasson, J
Dumont, Y
Griveau, JC
Ayache, C
机构
[1] Dept. Rech. Fond. Sur Matiere Cond., Laboratoire de Cryophysique, CEA Grenoble, 38054 Grenoble Cedex 09
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1997年 / 68卷 / 03期
关键词
D O I
10.1063/1.1147639
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the development of a technique to measure transport properties using a new diamond anvil cell and helium as pressure transmitting medium to ensure hydrostatic conditions. The chamber pressure is measured at any working temperature below 300 K by the ruby fluorescence method. This technique has been used to pressures up to 3 GPa at T=5 K to measure the effect of hydrostatic pressure and magnetic field on the superconducting transition temperature of a single crystal of the anisotropic cuprate superconductor Bi(2.1)Sr(1.9-y)La(y)CuO(6+delta). (C) 1997 American Institute of Physics.
引用
收藏
页码:1514 / 1517
页数:4
相关论文
共 50 条
  • [21] Pressure buffering in a diamond anvil cell
    Arlt, T
    Angel, RJ
    MINERALOGICAL MAGAZINE, 2000, 64 (02) : 241 - 245
  • [22] Twin sample chamber for simultaneous comparative transport measurements in a diamond anvil cell
    Schaeffer, Anne Marie J.
    Deemyad, Shanti
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (09):
  • [23] Ruby pressure scale in a low-temperature diamond anvil cell
    Yamaoka, Hitoshi
    Zekko, Yumiko
    Jarrige, Ignace
    Lin, Jung-Fu
    Hiraoka, Nozomu
    Ishii, Hirofumi
    Tsuei, Ku-Ding
    Mizuki, Jun'ichiro
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (12)
  • [24] ELECTRICAL TRANSPORT MEASUREMENTS IN A GASKETED DIAMOND ANVIL CELL UP TO 18 GPA
    GONZALEZ, J
    BESSON, JM
    WEILL, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (01): : 106 - 107
  • [25] High-pressure fluorescence measurements using a diamond anvil cell (DAC)
    Zhang, Haitao
    Xie, Changqing
    Ma, Zhiyong
    Xu, Weiqing
    Xu, Shuping
    Liu, Yu
    Geng, Yijia
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2025, 53 (01) : 1 - 12
  • [26] Contributed Review: Culet diameter and the achievable pressure of a diamond anvil cell: Implications for the upper pressure limit of a diamond anvil cell
    O'Bannon, Earl F., III
    Jenei, Zsolt
    Cynn, Hyunchae
    Lipp, Magnus J.
    Jeffries, Jason R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (11):
  • [27] Electrical conductivity measurements of aqueous fluids under pressure with a hydrothermal diamond anvil cell
    Ni, Huaiwei
    Chen, Qi
    Keppler, Hans
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [28] A compact bellows-driven diamond anvil cell for high-pressure, low-temperature magnetic measurements
    Feng, Yejun
    Silevitch, D. M.
    Rosenbaum, T. F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (03):
  • [29] ELECTRICAL-RESISTANCE MEASUREMENTS AT HIGH-PRESSURE AND LOW-TEMPERATURE USING A DIAMOND-ANVIL CELL
    SAKAI, N
    KAJIWARA, T
    TSUJI, K
    MINOMURA, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (04): : 499 - 502
  • [30] INTERFEROMETRIC HIGH-PRESSURE GAUGE FOR THE DIAMOND ANVIL CELL USEFUL AT HIGH-TEMPERATURES
    DAJORNADA, JAH
    BLOCK, S
    PIERMARINI, GJ
    APPLIED PHYSICS LETTERS, 1984, 45 (06) : 700 - 702