Determination of melarsoprol in biological fluids by high-performance liquid chromatography and characterisation of two stereoisomers by nuclear magnetic resonance spectroscopy

被引:12
|
作者
Ericsson, O
Schweda, EKH
Bronner, U
Rombo, L
Friden, M
Gustafsson, LL
机构
[1] HUDDINGE UNIV HOSP,DEPT CLIN LAB MED & TECHNOL,UNIT TROP PHARMACOL,S-14186 HUDDINGE,SWEDEN
[2] HUDDINGE UNIV HOSP,CLIN RES CTR NOVUM,S-14186 HUDDINGE,SWEDEN
[3] HUDDINGE UNIV HOSP,DIV INFECT DIS,UNIT TROP PHARMACOL,S-14186 HUDDINGE,SWEDEN
[4] HUDDINGE UNIV HOSP,DEPT CLIN LAB MED & TECHNOL,DIV CLIN PHARMACOL,UNIT TROP PHARMACOL,S-14186 HUDDINGE,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 690卷 / 1-2期
关键词
nuclear magnetic resonance spectroscopy; melarsoprol;
D O I
10.1016/S0378-4347(96)00418-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of melarsoprol in whole blood, plasma, urine and cerebrospinal fluid is described. Extraction was made with a mixture of chloroform and acetonitrile followed by back-extraction into phosphoric acid. A reversed-phase liquid chromatography system with ultraviolet detection was used, The relative standard deviation was 1% at concentrations around 10 mu mol/l and 3-6% at the lower limit of determination (9 nmol/l in plasma, 93 nmol/l in whole blood, 45 nmol/l in urine and 10 nmol/l in cerebrospinal fluid). Melarsoprol is not a stable compound and samples to be stored for longer periods of time should be kept at -70 degrees C. Plasma samples can be stored at -20 degrees C for up to 2 months. Chromatography showed that melarsoprol contains two components. Using nuclear magnetic resonance spectroscopy the two components were shown to be diastereomers which slowly equilibrate by inversion of the configuration at the As atom.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [21] DETERMINATION OF FLUNOXAPROFEN ENANTIOMERS IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PEDRAZZINI, S
    ZANOBONIMUCIACCIA, W
    SACCHI, C
    FORGIONE, A
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 415 (01): : 214 - 220
  • [22] DETERMINATION OF NAVELBINE AND DESACETYLNAVELBINE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    JEHL, F
    DEBS, J
    HERLIN, C
    QUOIX, E
    GALLION, C
    MONTEIL, H
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 525 (01): : 225 - 233
  • [23] MICROMETHOD FOR DETERMINATION OF CREATININE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SOLDIN, SJ
    HILL, JG
    CLINICAL CHEMISTRY, 1978, 24 (05) : 747 - 750
  • [24] DETERMINATION OF THE DIURETIC BUMETANIDE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MARCANTONIO, LA
    AULD, WHR
    SKELLERN, GG
    JOURNAL OF CHROMATOGRAPHY, 1980, 183 (01): : 118 - 123
  • [25] DETERMINATION OF ALCURONIUM CHLORIDE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PARKIN, JE
    JOURNAL OF CHROMATOGRAPHY, 1981, 225 (01): : 240 - 244
  • [26] Analysis of fluoroquinolones in biological fluids by high-performance liquid chromatography
    Carlucci, G
    JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 343 - 367
  • [27] Investigation of hop and beer bitter acids by coupling of high-performance liquid chromatography to nuclear magnetic resonance spectroscopy
    Pusecker, K
    Albert, K
    Bayer, E
    JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (02) : 245 - 252
  • [28] Phenylpropanoid interconversion in Anigozanthos preissii observed by high-performance liquid chromatography-nuclear magnetic resonance spectroscopy
    Schmitt, B
    Schneider, B
    PHYTOCHEMICAL ANALYSIS, 2001, 12 (01) : 43 - 47
  • [29] Identification of major metabolites in Aloe littoralis by high-performance liquid chromatography-nuclear magnetic resonance spectroscopy
    Karagianis, G
    Viljoen, A
    Waterman, PG
    PHYTOCHEMICAL ANALYSIS, 2003, 14 (05) : 275 - 280
  • [30] Implementation of real-time two-dimensional nuclear magnetic resonance spectroscopy for on-flow high-performance liquid chromatography
    Zhou, Zhiming
    Lan, Wenxian
    Zhang, Weinong
    Zhang, Xu
    Xia, Sheng'an
    Zhu, Hang
    Ye, Chaohui
    Liu, Maili
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 464 - 468