Characterising acetabular component orientation with pelvic motion during total hip arthroplasty

被引:6
|
作者
Killen, Cameron J. [1 ]
Murphy, Michael P. [1 ]
Ralles, Steven J. [1 ]
Khayatzadeh, Saeed [2 ]
Brown, Nicholas M. [1 ]
Patwardhan, Avinash G. [2 ]
Havey, Robert M. [2 ]
Wu Karen [1 ]
机构
[1] Loyola Univ Med Ctr, Dept Orthopaed Surg & Rehabil, 2160 S First Ave,Maguire Suite 1700, Maywood, IL 60153 USA
[2] Edward Hines Jr VA Hosp, Musculoskeletal Biomech Lab, Hines, IL USA
关键词
Acetabular component; anteversion; inclination; orientation; pelvic motion; total hip arthroplasty; CUP POSITION; LIGAMENT; REPLACEMENT; DISLOCATION; RISK; THA;
D O I
10.1177/1120700020925013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Suboptimal acetabular component position can result in impingement, dislocation, and accelerated wear. Intraoperative pelvic motion has led to surgeon error and acetabular cup malposition. This study characterises the relationship between pelvic rotation and postoperative acetabular cup orientation. Methods: A device was constructed to allow cadaveric pelvis rotation along three axes about an acetabular cup in fixed orientation. The acetabular cup was fixed in space at 40 degrees of radiographic inclination and 15 degrees of anteversion relative to the anterior pelvic plane to represent consistent surgeon intraoperative placement. Active marker clusters were fixed to surgical equipment while the cadaveric pelvis was cemented with passive reflective markers, both identified with the Optotrak Certus motion capture system. The reamed cadaveric pelvis was rotated along three axes from -45 degrees to 45 degrees of roll, -30 degrees to 30 degrees of tilt, and -35 degrees to 35 degrees of pitch. The change in component inclination and anteversion was recorded at each 5 degrees interval. Using computed tomography 3D reconstruction, the experimental setup was duplicated computationally to assess against a greater range of pelvis and implant sizes. Results: Radiographic anteversion and inclination showed a non-linear relationship dependent on pelvic roll, tilt, and pitch. Radiographic anteversion changed -0.59 degrees, 0.76 degrees and 0.01 degrees while radiographic inclination changed 0.23 degrees, 0.18 degrees and 1.00 degrees for every 1 degrees of pelvic roll, tilt and pitch, respectively. Computationally, anteversion changed -0.61 degrees, 0.75 degrees and 0.00 degrees while inclination changed 0.22 degrees, 0.19 degrees and 1.00 degrees for every 1 degrees of pelvic roll, tilt and pitch, respectively. These results were independent of cup and pelvis size. Conclusions: Intraoperative pelvic motion can significantly affect final cup position, and this should be accounted for when placing acetabular components during total hip arthroplasty. Based on this study, intraoperative adjustment of the acetabular component position based on pelvis motion may be implemented to improve postoperative component position.
引用
收藏
页码:743 / 750
页数:8
相关论文
共 50 条
  • [21] Intraoperative pelvic motion in total hip arthroplasty
    Asayama, I
    Akiyoshi, Y
    Naito, M
    Ezoe, M
    JOURNAL OF ARTHROPLASTY, 2004, 19 (08): : 992 - 997
  • [22] Pelvic motion during total hip arthroplasty with translateral and posterolateral approaches
    Ezoe, M
    Naito, M
    Asayama, I
    Ishiko, T
    Fujisawa, M
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2005, 10 (02) : 167 - 172
  • [23] Operative and radiographic acetabular component orientation in total hip replacement: Influence of pelvic orientation and surgical positioning technique
    Rutherford, Megan
    O'Connor, John D.
    Gill, Harinderjit S.
    Hill, Janet
    Beverland, David
    Lennon, Alex B.
    Dunne, Nicholas J.
    MEDICAL ENGINEERING & PHYSICS, 2019, 64 : 7 - 14
  • [24] Anteversion of the Acetabular Component Aligned With the Transverse Acetabular Ligament in Total Hip Arthroplasty
    Miyoshi, Hideaki
    Mikami, Hiroshi
    Oba, Koichi
    Amari, Rui
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 916 - 922
  • [25] Acetabular Considerations During Total Hip Arthroplasty for Hip Dysplasia
    Dapuzzo, Michele R.
    Sierra, Rafael J.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2012, 43 (03) : 369 - +
  • [26] CEMENTLESS FIXATION OF THE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY
    DEKLERK, AJ
    BOMBELLI, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03): : 447 - 447
  • [27] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Ozan, Firat
    Kahraman, Murat
    Baktir, Ali
    Gencer, Kursat
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [28] The influence of acetabular component position on wear in total hip arthroplasty
    Wan, Zhinian
    Boutary, Myriam
    Dorr, Lawrence D.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 51 - 56
  • [29] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Fırat Ozan
    Murat Kahraman
    Ali Baktır
    Kürşat Gençer
    Journal of Orthopaedic Surgery and Research, 16
  • [30] Are Acetabular Component Alignment Guides for Total Hip Arthroplasty Accurate?
    Minoda, Yukihide
    Ohzono, Kenji
    Aihara, Masaharu
    Umeda, Naoya
    Tomita, Masuhiro
    Hayakawa, Keiko
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 986 - 989