Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery

被引:33
|
作者
Tanyi, J. A. [1 ,2 ]
Kato, C. M. [3 ]
Chen, Y. [4 ]
Chen, Z. [5 ]
Fuss, M. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Radiat Med, Portland, OR 97239 USA
[2] Oregon State Univ, Dept Nucl Engn & Radiat Hlth Phys, Corvallis, OR 97331 USA
[3] Macalester Coll, St Paul, MN 55105 USA
[4] Oregon Hlth & Sci Univ, Dept Publ Hlth & Prevent Med, Portland, OR 97239 USA
[5] Oregon Hlth & Sci Univ, Oregon Clin & Translat Res Inst, Portland, OR 97239 USA
来源
BRITISH JOURNAL OF RADIOLOGY | 2011年 / 84卷 / 1003期
关键词
INTENSITY-MODULATED RADIOSURGERY; MLC LEAF WIDTH; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; DOSE DISTRIBUTIONS; TREATMENT PLANS; SKULL-BASE; LESIONS; SYSTEM; IMRT;
D O I
10.1259/bjr/19726857
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The impact of two multileaf collimator (MLC) systems for linear accelerator-based intracranial stereotactic radiosurgery (SRS) was assessed. Methods: 68 lesions formed the basis of this study. 2.5 mm leaf width plans served as reference. Comparative plans, with identical planning parameters, were based on a 5 mm leaf width MLC system. Two collimation strategies, with collimation fixed at 0 degrees or 90 degrees and optimised per arc or beam, were also assessed. Dose computation was based on the pencil beam algorithm with allowance for tissue heterogeneity. Plan normalisation was such that 100% of the prescription dose covered 95% of the planning target volume. Plan evaluation was based on target coverage and normal tissue avoidance criteria. Results: The median conformity index difference between the MLC systems ranged between 0.8% and 14.2%; the 2.5 mm MLC exhibited better dose conformation. The median reduction of normal tissue exposed to >= 100%, >= 50% and >= 25% of the prescription dose ranged from 13.4% to 29.7%, favouring the 2.5 mm MLC system. Dose fall-off was steeper for the 2.5 mm MLC system with an overall median absolute difference ranging from 0.4 to 1.2 mm. The use of collimation optimisation resulted in a decrease in differences between the MLC systems. The results demonstrated the dosimetric merit of the 2.5 mm leaf width MLC system over the 5 mm leaf width system, albeit small, for the investigated range of intracranial SRS targets. Conclusion: The clinical significance of these results warrants further investigation to determine whether the observed dosimetric advantages translate into outcome improvements.
引用
收藏
页码:629 / 638
页数:10
相关论文
共 50 条
  • [41] Intracranial stereotactic radiosurgery with an adapted linear accelerator vs. robotic radiosurgery
    Treuer, Harald
    Hoevels, Moritz
    Luyken, Klaus
    Visser-Vandewalle, Veerle
    Wirths, Jochen
    Kocher, Martin
    Ruge, Maximilian
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (06) : 470 - 476
  • [42] Impact of tumour volume and treatment delay on the outcome after linear accelerator-based fractionated stereotactic radiosurgery of uveal melanoma
    Sreenivasa, Shanthala
    Woesle, Markus
    Gager, Yann
    Vordermark, Dirk
    Grajewski, Luise
    Krause, Lothar
    Ciernik, I. Frank
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (03) : 457 - 464
  • [43] A single-center experience with linear accelerator-based stereotactic radiotherapy for meningiomas: hypofractionation and radiosurgery
    Gawish, Ahmed
    Abdulayev, Nurlan
    El-Arayed, Souhir
    Roellich, Burkard
    Ochel, Hans-Joachim
    Brunner, Thomas B.
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (01) : 103 - 109
  • [44] LINEAR ACCELERATOR-BASED STEREOTAXIC RADIOSURGERY FOR ACOUSTIC NEUROMAS
    MENDENHALL, WM
    FRIEDMAN, WA
    BOVA, FJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 151 - 151
  • [45] A single-center experience with linear accelerator-based stereotactic radiotherapy for meningiomas: hypofractionation and radiosurgery
    Ahmed Gawish
    Nurlan Abdulayev
    Souhir El-Arayed
    Burkard Röllich
    Hans-Joachim Ochel
    Thomas B. Brunner
    Journal of Cancer Research and Clinical Oncology, 2023, 149 : 103 - 109
  • [46] Linear accelerator-based stereotactic radiosurgery for glossopharyngeal neuralgia is safe and effective - Report of two cases
    Pathmarajah, Thamilini
    Katipally, Rohan R.
    Flores-Martinez, Everardo
    Farrey, Karl J.
    Korpics, Mark C.
    Sivananthan, Aranee P.
    Warnke, Peter C.
    Chmura, Steven J.
    Yenice, Kamil M.
    Pitroda, Sean P.
    JOURNAL OF RADIOSURGERY AND SBRT, 2022, 8 (02): : 151 - 153
  • [47] Linear accelerator-based stereotactic radiosurgery for bilateral vestibular schwannomas in patients with neurofibromatosis Type 2
    Meijer, Otto W. M.
    Vandertop, W. Peter
    Lagerwaard, Frank J.
    Slotman, Ben J.
    NEUROSURGERY, 2008, 62 (05) : A37 - A42
  • [48] LINEAR ACCELERATOR-BASED STEREOTAXIC RADIOSURGERY FOR ACOUSTIC SCHWANNOMAS
    MENDENHALL, WM
    FRIEDMAN, WA
    BOVA, FJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04): : 803 - 810
  • [49] CLINICAL EXPERIENCES WITH ONBOARD IMAGER KV IMAGES FOR LINEAR ACCELERATOR-BASED STEREOTACTIC RADIOSURGERY AND RADIOTHERAPY SETUP
    Hong, Linda X.
    Chen, Chin C.
    Garg, Madhur
    Yaparpalvi, Ravindra
    Mah, Dennis
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02): : 556 - 561
  • [50] Linear accelerator-based stereotactic radiosurgery for limited, locally persistent, and recurrent nasopharyngeal carcinoma: Efficacy and complications
    Chua, DTT
    Sham, JST
    Kwong, PWK
    Hung, KN
    Leung, LHT
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 177 - 183