Retrofitting of an air-cooled data center for energy efficiency

被引:20
|
作者
Kuzay, Mustafa [1 ,4 ]
Dogan, Aras [1 ,4 ]
Yilmaz, Sibel [1 ]
Herkiloglu, Oguzhan [2 ]
Atalay, Ali Serdar [2 ]
Cemberci, Atilla [2 ]
Yilmaz, Cagatay [3 ]
Demirel, Ender [1 ,4 ]
机构
[1] Design & Simulat Tech Inc, TR-26480 Eskisehir, Turkey
[2] Radius Solut Ctr, Bahar Arkasi St 11, TR-34692 Istanbul, Turkey
[3] Lande Ind Met Prod Inc Co, Organized Ind Zone, 20th St 14, Eskisehir, Turkey
[4] Eskisehir Osmangazi Univ, TR-26480 Eskisehir, Turkey
关键词
Data center; Thermal efficiency; Cooling efficiency; CFD modeling; Open-source; MANAGEMENT;
D O I
10.1016/j.csite.2022.102228
中图分类号
O414.1 [热力学];
学科分类号
摘要
Small-scale data centers suffering from low cooling efficiency consume an intense power for reliable operation of IT equipment. In this study, thermal distribution in an air-cooled data center is simulated using an open source Computational Fluid Dynamics (CFD) model to examine the underlying mechanism that reduces thermal and cooling efficiencies. The numerical model is validated with the temperature measurements conducted in the data center. Numerical simulations have revealed that recirculating hot flows observed at the top of the racks increased the air temperature beyond the allowable maximum temperature. To this end, the data center has been retrofitted by creating a hot aisle with the implementation of a moving baffle at the rear of the rack. Numerical simulations conducted for two working scenarios have demonstrated that such a minor modification could result in remarkable enhancement in the cooling efficiency. Efficiency of the data center has improved by 47.2% and 22.7% with respect to the RCI (Rack Cooling Index) and RHI (Return Heat Index), respectively. The present numerical model can capture distributions of the efficiency metrics over the racks. Present methodology can be used to reduce power consumption by the cooling and ventilation systems in existing data centers.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Experimental determination of the energy efficiency of an air-cooled chiller under part load conditions
    Yu, FW
    Chan, KT
    ENERGY, 2005, 30 (10) : 1747 - 1758
  • [22] The Impact of Placement-Related Effects in Air-Cooled Cooling Chillers on Energy Efficiency
    Ozel, Burak
    Kavas, Suleyman
    53RD AICARR INTERNATIONAL CONFERENCE FROM NZEB TO ZEB: THE BUILDINGS OF THE NEXT DECADES FOR A HEALTHY AND SUSTAINABLE FUTURE, 2024, 523
  • [23] Improving the energy efficiency of refrigeration plants by decreasing the temperature difference in air-cooled condensers
    Shishov V.V.
    Talyzin M.S.
    Thermal Engineering, 2015, 62 (9) : 652 - 655
  • [24] Energy efficiency and performance considerations of variable frequency drives for air-cooled heat exchangers
    Endrejat, F
    van Niekerk, HR
    Delport, GJ
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 98) - PROCEEDINGS, VOLS 1 AND 2, 1998, : 312 - 316
  • [25] AIR-COOLED SILENCER
    HULL, WQ
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1951, 43 (11): : A13 - +
  • [26] Air-cooled condenser
    Phogat, S.S.
    Journal of the Institution of Engineers (India): Mechanical Engineering Division, 1988, 68 pt 6 : 191 - 195
  • [27] AIR-COOLED TURBOGENERATORS
    ALWERS, E
    MERZ, K
    ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1977, 98 (10): : 661 - 661
  • [28] Air-cooled extruders
    Mod Plast, 2 (81):
  • [29] AIR-COOLED EQUIPMENT
    不详
    COKE & CHEMISTRY USSR, 1968, (05): : 52 - &
  • [30] High-pulse-energy air-cooled lasers
    Kilmer, Joyce
    Kilmer, Joyce (jkilmer@photonix.com), 1600, Laurin Publishing Co. Inc. (54): : 45 - 49