Congestion-aware robust security constrained unit commitment model for AC-DC grids

被引:10
|
作者
Jiang, Sufan [1 ]
Gao, Shan [1 ]
Pan, Guangsheng [1 ]
Liu, Yu [1 ]
Wu, Chuanshen [1 ]
Wang, Sicheng [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing, Peoples R China
关键词
Congestion management; High Voltage Direct Current (HVDC) system security constrained unit commitment (SCUC); Wind uncertainty budget sets; Congestion-aware factors; RENEWABLE ENERGY; POWER-FLOW; UNCERTAINTY; SYSTEM; STABILITY; DISPATCH; NETWORK; STORAGE; GAS;
D O I
10.1016/j.apenergy.2021.117392
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the increasing penetration of wind energy, their natural volatility may cause power flow congestions by blocking some key transmission interfaces. To further reduce energy violations induced by uncertainty issues and ensure the system reliability, the controllability of High Voltage Direct Current (HVDC) system should be exploited in AC-DC grids. By leveraging the congestion management capabilities of HVDC, we propose a congestion-aware robust security constrained unit commitment (SCUC) model, to preemptively consider the plausible congestion circumstances in a more adaptive way in the day-ahead (DA) market. In our model, the conventional uncertainty budget sets are modified by the proposed congestion-aware factors, where the typical operational characteristics of traditional corrective actions and HVDC regulations in real-time (RT) market are formulated adaptively. Moreover, the feasibility region of proposed problem is further pruned by the optimality cut planes where more pertinent real-time information are included, thus the local optimal solution is eliminated and the superior economic benefits are obtained in our model. To solve this mix-integer linear problem (MILP), the model is divided into three parts including the DA decision model, the traditional corrective dispatch model, and the HVDC regulation dispatch model. Correspondingly, an improved three-level Benders Decomposition algorithm is developed to solve the model. The enhanced performance of the proposed model was validated in a modified IEEE 118-bus test case. The results show that, in our model, the flexible regulation of HVDC system optimally allocate the operational burdens between DA and RT markets, thus the congestion-aware robust SCUC model further captures the economic benefits when ensuring the model's robustness.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Security-constrained AC-DC hybrid distribution system expansion planning with high penetration of renewable energy
    Liu, Pengxiang
    Wu, Zhi
    Gu, Wei
    Lu, Yuping
    Yang, Xuan
    Sun, Ke
    Sun, Qirun
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 142
  • [42] Coordinative frequency-constrained unit commitment model for HVDC interconnected AC systems
    Jiang, Sufan
    Wu, Chuanshen
    Gao, Shan
    Pan, Guangsheng
    Wang, Sicheng
    Liu, Yu
    Zhao, Xin
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [43] Distributed AC security-constrained unit commitment for multi-area interconnected power systems
    Zhang, Chen
    Yang, Linfeng
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 211
  • [44] Exploring the reliability effects on the short term AC security-constrained unit commitment: A stochastic evaluation
    Aghaei, Jamshid
    Nikoobakht, Ahmad
    Siano, Pierluigi
    Nayeripour, Majid
    Heidari, Alireza
    Mardaneh, Mohammad
    ENERGY, 2016, 114 : 1016 - 1032
  • [45] Security-Constrained Unit Commitment Considering Locational Frequency Stability in Low-Inertia Power Grids
    Tuo, Mingjian
    Li, Xingpeng
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2023, 38 (05) : 4134 - 4147
  • [46] An Incentive Mechanism for Electric Vehicles Participation in Security Constrained Unit Commitment of Renewable-Integrated Smart Grids
    Akbari, Amirhossein
    Alavi-Koosha, Ahmadreza
    Moradi-Sepahvand, Mojtaba
    Toulabi, Mohammadreza
    Amraee, Turaj
    Bathaee, Seyyed Mohammad Taghi
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (03) : 3824 - 3834
  • [47] Novel Formulation of PTDF and LODF Matrices for Security Constrained Optimal Power Flow for Hybrid AC and DC Grids
    Giuntoli, Marco
    Biagini, Veronica
    Schoenleber, Kevin
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,
  • [48] Decentralized robust unit commitment for AC/DC interconnected power systems considering wind power uncertainty
    Zhang, Gaohang
    Li, Fengting
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [49] Robust Chance-constrained Security Region Model of AC/DC Hybrid Distribution Network Considering the Uncertainty of Photovoltaic Generation
    Wei Z.
    Ma Z.
    Chen S.
    Zheng Y.
    Wu T.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (06): : 2208 - 2219
  • [50] A Comprehensive Model for Security-Constrained Unit Commitment Considering Renewable Energy Resources
    Alipour, Manijeh
    Jalali, Mehdi
    Zare, Kazem
    2015 SMART GRID CONFERENCE (SGC 2015), 2015, : 1 - 6