Calibrations of CR39 and Makrofol nuclear track detectors and search for exotic particles

被引:0
|
作者
Togo, V [1 ]
Ambrosio, M [1 ]
Antolini, R [1 ]
Auriemma, G [1 ]
Bakari, D [1 ]
Baldini, A [1 ]
Barbarino, GC [1 ]
Barish, BC [1 ]
Battistoni, G [1 ]
Becherini, Y [1 ]
Bellotti, R [1 ]
Bemporad, C [1 ]
Bernardini, P [1 ]
Bilokon, H [1 ]
Bloise, C [1 ]
Bower, C [1 ]
Brigida, M [1 ]
Bussino, S [1 ]
Cafagna, F [1 ]
Campana, D [1 ]
Carboni, M [1 ]
Caruso, R [1 ]
Cecchini, S [1 ]
Cei, F [1 ]
Chiarella, V [1 ]
Chiarusi, T [1 ]
Choudhary, BC [1 ]
Coutu, S [1 ]
Cozzi, M [1 ]
De Cataldo, G [1 ]
Dekhissi, H [1 ]
De Marzo, C [1 ]
Erriquez, O [1 ]
Favuzzi, C [1 ]
Forti, C [1 ]
Fusco, P [1 ]
Giacomelli, G [1 ]
Giannini, G [1 ]
Giglietto, N [1 ]
Giorgini, M [1 ]
Grassi, M [1 ]
Grillo, A [1 ]
Guarino, F [1 ]
Gustavino, C [1 ]
Habig, A [1 ]
Hanson, K [1 ]
Heinz, R [1 ]
Iarocci, E [1 ]
Katsavounidis, E [1 ]
Katsavounidis, I [1 ]
机构
[1] Ist Nazl Fis Nucl, Sez Bologna, I-40127 Bologna, Italy
关键词
D O I
10.1016/S0920-5632(03)90994-7
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
We present the final results of the search for exotic massive particles in the cosmic radiation performed with the MACRO underground experiment. Magnetic monopoles and nuclearites flux upper limits obtained with the CR39 nuclear track subdetector, the scintillation and streamer tube subdetectors are given. Searches at high altitude with the SLIM experiment are in progress.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 50 条
  • [21] Spectroscopic analysis of alpha particles from radioactive nuclides with CR-39 plastic nuclear track detectors
    Kodaira, Satoshi
    Janik, Miroslaw
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (16-18) : 1686 - 1691
  • [22] Calibration Of CR39 Track Etch Detectors Using 600 A MeV Si14+ Ion Beam
    Kumar, Ashavani
    Gupta, Renu
    PROCEEDING OF INTERNATIONAL CONFERENCE ON RECENT TRENDS IN APPLIED PHYSICS & MATERIAL SCIENCE (RAM 2013), 2013, 1536 : 1099 - 1100
  • [23] Extended calibration of a CR39 nuclear track detector with 158 a GeV 207Pb ions
    Giacomelli, G
    Giorgini, M
    Mandrioli, G
    Manzoor, S
    Patrizii, L
    Popa, V
    Serra, P
    Togo, V
    Vilela, EC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 411 (01): : 41 - 45
  • [24] INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS
    Robu, Elena
    Maringer, Franz Josef
    Garavalia, Massimo
    Picini, Luca
    ROMANIAN REPORTS IN PHYSICS, 2011, 63 (02) : 376 - 382
  • [25] ELECTROCHEMICAL ETCHING OF CR-39 AND MAKROFOL DE TRACK DETECTORS - INVESTIGATION OF PARAMETERS AFFECTING THE OVERALL UNCERTAINTY OF MEASUREMENT
    PIESCH, E
    BURGKHARDT, B
    SAUER, D
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 211 - 214
  • [26] Note: Fast neutron efficiency in CR-39 nuclear track detectors
    Cavallaro, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (03):
  • [27] Supervised nuclear track detection of CR-39 detectors by cellular automata
    Nejad, Hadi Chahkandi
    Khayat, Omid
    Mohammadi, Kheirollah
    Tavakoli, Saeed
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (05): : 478 - 484
  • [28] Calculations of track parameters and plots of track openings and wall profiles in CR39 detector
    Nikezic, D
    Yu, KN
    RADIATION MEASUREMENTS, 2003, 37 (06) : 595 - 601
  • [29] Detection and identification of Pu particles and HEU particles by nuclear detectors CR-39
    Wang, Chen
    Guo, Shi-Lun
    Chang, Zhi-Yuan
    Liu, Guo-Rong
    Zhao, Yong-Gang
    RADIATION MEASUREMENTS, 2018, 119 : 174 - 178
  • [30] Further studies on ageing and fading of CR39 PADC track detectors used as air radon concentration measurement devices
    Caresana, M.
    Ferrarini, M.
    Garlati, L.
    Parravicini, A.
    RADIATION MEASUREMENTS, 2011, 46 (10) : 1160 - 1167