A calibration theory and method named nose-to-nose based on the agilent broadband sampling oscilloscopes

被引:0
|
作者
Zhu, JM [1 ]
Liu, ML [1 ]
Gao, Y [1 ]
Deng, C [1 ]
机构
[1] Beijing Univ Technol, Coll Elect & Control Engn, Beijing 100022, Peoples R China
关键词
nose-to-nose; broadband sampling oscilloscope; calibration; impulse response function;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The nose-to-nose (NTN) calibration theory is introduced by Ken Rush and Dr. Jan Verspecht in 1994 after several years study, it is an accurate method to determine the impulse response of broadband sampling oscilloscopes. The method is based on the hypothesis "sampler's kick-out pulse equals oscilloscope impulse response". We have studied the theory from stimulation to experiment. In this paper, the kick-out pulse and the response of the kick-out pulse are presented using PSPICE and MATLAB software. And two same Agilent 86100 types are connected to obtain the response waveform of the kick-out pulse. Although data processing is not perfect yet, simple introductions are given in this artical.
引用
收藏
页码:3051 / 3054
页数:4
相关论文
共 50 条
  • [1] New progress in theory of nose-to-nose calibration of broadband sampling oscilloscope
    Lin, M.L.
    Zhao, H.
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2001, 29 (03): : 409 - 411
  • [2] INDIVIDUAL CHARACTERIZATION OF BROAD-BAND SAMPLING OSCILLOSCOPES WITH A NOSE-TO-NOSE CALIBRATION PROCEDURE
    VERSPECHT, J
    RUSH, K
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1994, 43 (02) : 347 - 354
  • [3] Auto-calibrating system of broadband sampling oscilloscope based on nose-to-nose calibration procedure
    Zhao, Ke-Jia
    Liu, Ming-Liang
    Gao, Xiao-Xun
    Lu, Feng
    Zhu, Jiang-Miao
    Miao, Jing-Yuan
    Jiliang Xuebao/Acta Metrologica Sinica, 2006, 27 (04): : 388 - 391
  • [4] Systematic error of the nose-to-nose sampling-oscilloscope calibration
    Williams, Dylan F.
    Clement, Tracy S.
    Remley, Kate A.
    Hale, Tatil D.
    Verbeyst, Frans
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2007, 55 (09) : 1951 - 1957
  • [5] Sources of uncertainty in the nose-to-nose sampler calibration method
    Paulter, NG
    Larson, DR
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (05) : 1618 - 1626
  • [6] Research on the uncertainty of transition duration of broadband sampling oscilloscope based on nose-to-nose technology
    Yu, Yue-Hua
    Liu, Ming-Liang
    Zhao, Ke-Jia
    Zhao, Yi
    Zhu, Jiang-Miao
    Miao, Jing-Yuan
    Jiliang Xuebao/Acta Metrologica Sinica, 2007, 28 (01): : 81 - 84
  • [7] The simulation of the nose-to-nose calibration procedure
    Zhu, JM
    Liu, ML
    Gao, Y
    ICEMI'2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1-3, 2003, : 1217 - 1220
  • [8] Extended "Nose-to-Nose" calibration procedure
    Liu, ML
    Wang, YT
    Miao, JY
    Yu, YH
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 2, 2005, : 641 - 645
  • [9] Nose-to-nose oscilloscope calibration phase error inherent in the sampling circuitry
    Remley, KA
    ARFTG: AUTOMATIC RF TECHNIQUES GROUP, CONFERENCE DIGEST, FALL 2002: MEASUREMENTS NEEDS FOR EMERGING TECHNOLOGIES, 2002, : 85 - 97
  • [10] Novel research of nose-to-nose calibration foundation
    Zhu, JM
    Liu, ML
    Lu, F
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 8183 - 8187