Parallel Grafting Should Be Considered as a Viable Alternative to Open Repair in High-Risk Patients With Paravisceral Aortic Aneurysms

被引:3
|
作者
Alfawaz, Abdullah A. [1 ,2 ]
Dunphy, Kaitlyn M. [2 ]
Abramowitz, Steven D. [2 ]
Kiguchi, Misaki M. [2 ]
Dearing, Joshua A. [2 ]
Shults, Christian C. [3 ]
Woo, Edward Y. [2 ]
机构
[1] Kuwait Univ, Dept Surg, Fac Med, Kuwait, Kuwait
[2] MedStar Washington Hosp Ctr, Dept Vasc Surg, Washington, DC USA
[3] MedStar Washington Hosp Ctr, Dept Cardiac Surg, Washington, DC USA
关键词
CELIAC ARTERY; EXPERIENCE; ENDOLEAKS; COVERAGE; SAFETY;
D O I
10.1016/j.avsg.2020.12.043
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Parallel grafting presents a viable method for treating patients with complex aortic aneurysms. The current literature is limited to mostly pararenal configurations. We examined our results in patients with SMA and/or Celiac artery involvement. Methods: A retrospective analysis was performed for all patients undergoing parallel grafting dur ing the per iod of 2014 to 2018 at a single institution. All patients had at least SMA with and/or without Celiac artery parallel grafting. Results: Seventy-nine patients (65% male, median age 74) were treated with 208 parallel grafts. Median ASA score is 4. Forty-nine cases were elective, 22 urgent, and 8 emergent. Mean preoperative aneurysm diameter was 7.1 cm (4.6-15 cm). Self-expanding covered stents were used for the renal arteries (mean 6.3mm), and balloon-expandable covered stents were used for the SMA and Celiac (mean SMA 8.6 mm, mean celiac 8.3 mm). Axillary exposure was the choice of access in 68 patients (86%). Technical success was achieved in all cases. We defined this as aneurysm sac exclusion with patent visceral stent grafts, and absent to mild gutter leaks. Mean aortic graft proximal seal achieved was 48mm. Coverage extended above the celiac artery in 75% (10% stented and 65% covered). Median contrast volume was 145ml, operative duration was 4 hours, fluoroscopy time was 56 min, and EBL was 250 ml. Perioperative mortality was 6.1%. 4.5%, and 25%, for the elective, urgent, and emergent groups, respectively. There was no incidence of spinal cord ischemia. Axillary access was complicated in 4 patients, requiring patch closure of the axillar y arter y. One patient developed postprocedural ESRD from a rupture and ATN despite patent renal stents. Of those patients with a patent GDA and celiac coverage, 2 required a cholecystectomy. Nine patients had a persistent gutter leak at the conclusion of the procedure. Median follow-up was 12 months. On follow-up imaging, all SMA and Celiac stents were patent. Six renal stents were occluded and 2 patients progressed to ESRD, both solitary renal periscope configurations at the index procedure. Only 4 patients had persistent gutter leaks with 2 requiring reintervention. Ninety-five percent of patients demonstrated sac regression or stabilization with a mean sac size of 6.5 cm. Conclusions: Parallel grafting presents a safe, efficacious and off the shelf alternative to conventional repair of complex aortic aneurysms involving the visceral aorta.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [21] Abdominal aortic aneurysm repair in high-risk and elderly patients
    Geraghty, PJ
    Sicard, GA
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04): : 543 - 547
  • [22] Hybrid repair of aortic arch aneurysm in high-risk patients
    Campanella, Antonio
    Rinaldi, Mauro
    Rispoli, Pietro
    Gandini, Giovanni
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2011, 12 (02) : 138 - 144
  • [23] The anesthetic technique of choice for better outcomes in high-risk elderly patients undergoing endovascular repair of aortic aneurysms
    Lippmann, Maurice
    Karnwal, Abhishek
    Julka, Inderjeet S.
    Kakazu, Clinton Z.
    White, Rodney
    JOURNAL OF ANESTHESIA, 2010, 24 (03) : 499 - 499
  • [24] The anesthetic technique of choice for better outcomes in high-risk elderly patients undergoing endovascular repair of aortic aneurysms
    Maurice Lippmann
    Abhishek Karnwal
    Inderjeet S. Julka
    Clinton Z. Kakazu
    Rodney White
    Journal of Anesthesia, 2010, 24 : 499 - 499
  • [25] Risk Stratification of Ruptured Abdominal Aortic Aneurysms in Patients Treated by Open Surgical Repair
    Krenzien, F.
    Wiltberger, G.
    Hau, H. -M.
    Matia, I.
    Benzing, C.
    Atanasov, G.
    Schmelzle, M.
    Fellmer, P. T.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 51 (01) : 30 - 36
  • [26] Catheter-assisted Aortic Valve Replacement: Alternative to open Surgery in High-risk Patients Comments
    Walther, T.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2009, 23 (02): : 123 - 124
  • [27] Endovascular aortic repair or minimal incision aortic surgery: Which procedure to choose for treatment of high-risk aneurysms?
    Tefera, G
    Carr, SC
    Turnipseed, WD
    SURGERY, 2004, 136 (04) : 748 - 752
  • [28] Endovascular repair of expanding thoracic aortic aneurysms in high surgical risk patients
    Chang, James M.
    Davila, Victor J.
    Lanza, Louis A.
    Ramakrishna, Harish
    Fowl, Richard J.
    Money, Samuel R.
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (01) : 158 - 161
  • [29] SURGERY FOR ABDOMINAL AORTIC-ANEURYSMS - WITH SPECIAL REFERENCE TO HIGH-RISK PATIENTS
    NASH, T
    GOLD, J
    MEDICAL JOURNAL OF AUSTRALIA, 1983, 2 (09) : 434 - 436
  • [30] Endovascular stent grafting for ascending aorta repair in high-risk patients Discussion
    Roselli
    Miller
    Jones
    Shemin
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (01): : 151 - 154