Intravascular contrast agent improves magnetic resonance angiography of carotid arteries in minipigs

被引:26
|
作者
Lin, WL [1 ]
Abendschein, DR [1 ]
Celik, A [1 ]
Dolan, RP [1 ]
Lauffer, RB [1 ]
Walovitch, RC [1 ]
Haacke, EM [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, Dept Elect Engn, St Louis, MO 63110 USA
来源
关键词
MRA; intravascular and extravascular contrast agents; angioplasty;
D O I
10.1002/jmri.1880070605
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was designed to optimize three-dimensional (3D) time-of-night (TOF) magnetic resonance angiography (MRA) sequences and to determine whether contrast-enhanced MRA could improve the accuracy of lumen definition in stenosed carotid arteries of minipigs, 3D TOF MRA was acquired with use of either an intravascular (n = 13) and/or an extravascular contrast agent (n = 5) administrated at 2 to 4 weeks after balloon-induced injury to a carotid artery in 16 minipigs. Vascular contrast, defined as signal intensity differences between blood vessels and muscle normalized to the signal intensity of muscle, was compared before and after the injection of each contrast agent and between the two agents. Different vascular patencies were observed among the animals, including completely occluded vessels (n = 5), stenotic vessels (n = 3), and vessels with no visible stenosis (n = 8), Superior vascular contrast improvement was observed for small arteries and veins and for large veins with the intravascular contrast agent when compared with the extravascular contrast agent. In addition, preliminary studies in two of the animals showed a good correlation for the extent of luminal stenosis defined by digital subtraction angiography compared with MRA obtained after administration of the intravascular contrast agent (R2 =.71, with a slope of.96 +/- .04 by a linear regression analysis). We concluded that use of an intravascular contrast agent optimizes 3D TOF MRA and may improve its accuracy compared with digital subtraction angiography.
引用
收藏
页码:963 / 971
页数:9
相关论文
共 50 条
  • [41] CAROTID ANGIOGRAPHY BY MAGNETIC-RESONANCE
    FRIEDRICH, JM
    NOLDECKE, HA
    TOMCZAK, R
    MERKLE, E
    OREND, KH
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1993, 42 (08): : A69 - A75
  • [42] A glycosylated complex of gadolinium, a new potential contrast agent for magnetic resonance angiography?
    Yu, G.
    Yamashita, M.
    Aoshima, K.
    Takahashi, M.
    Oshikawa, T.
    Takayanagi, H.
    Laurent, S.
    Burtea, C.
    Vander Elst, L.
    Muller, R. N.
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2007, 17 (08) : 2246 - 2249
  • [43] High-Resolution Steady State Magnetic Resonance Angiography of the Carotid Arteries: Are Intravascular Agents Necessary? Feasibility and Preliminary Experience With Gadobenate Dimeglumine
    Anzidei, Michele
    Napoli, Alessandro
    Marincola, Beatrice Cavallo
    Kirchin, Miles A.
    Neira, Cristina
    Geiger, Daniel
    Zaccagna, Fulvio
    Catalano, Carlo
    Passariello, Roberto
    INVESTIGATIVE RADIOLOGY, 2009, 44 (12) : 784 - 792
  • [44] Contrast-enhanced magnetic resonance angiography of the iliac arteries: Optimization by injection simulation
    Schmidt, MA
    Britten, AJ
    Tomlinson, MA
    Vig, S
    Powell, S
    Cleminson, S
    Kerr, E
    Blundell, J
    Heron, CW
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 365 - 373
  • [45] Renal Transplant Imaging Using Magnetic Resonance Angiography With a Nonnephrotoxic Contrast Agent
    Bashir, Mustafa R.
    Jaffe, Tracy A.
    Brennan, Todd V.
    Patel, Uptal D.
    Ellis, Matthew J.
    TRANSPLANTATION, 2013, 96 (01) : 91 - 96
  • [46] Equilibrium phase MR-angiography of the aorto-iliac and renal arteries using an intravascular contrast agent
    Weishaupt, D
    Ruehm, SG
    Binkert, CA
    Patak, MA
    Steybe, F
    Debatin, JF
    RADIOLOGY, 1999, 213P : 270 - 271
  • [47] Multi-phase coronary magnetic resonance angiography improves delineation of coronary arteries
    Zitzelsberger, Tanja
    Krumm, Patrick
    Hornung, Andreas
    Kramer, Ulrich
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Schick, Fritz
    Sieverding, Ludger
    Martirosian, Petros
    ACTA RADIOLOGICA, 2019, 60 (11) : 1422 - 1429
  • [48] Contrast-enhanced magnetic resonance angiography of the carotid arteries:: Influence of injection rates and volumes on arterial-venous transit time
    Herold, T
    Paetzel, C
    Völk, M
    Bachthaler, M
    Zorger, N
    Feuerbach, S
    Strotzer, M
    Lenhart, M
    INVESTIGATIVE RADIOLOGY, 2004, 39 (02) : 65 - 72
  • [49] Contrast-enhanced Magnetic Resonance Angiography of the carotid arteries in a time-resolved technique: Diagnostic accuracy and interobserver variability in comparison with selective catheter angiography
    Lenhart, M
    Framme, N
    Voelk, M
    Strotzer, M
    Link, J
    Feuerbach, SG
    RADIOLOGY, 2001, 221 : 298 - 299
  • [50] Ultra-Low-Dose, Time-Resolved Contrast-Enhanced Magnetic Resonance Angiography of the Carotid Arteries at 3.0 Tesla
    Lohan, Derek G.
    Tomasian, Anderanik
    Saleh, Roya S.
    Singhal, Aparna
    Krishnam, Mayd S.
    Finn, J. Paid
    INVESTIGATIVE RADIOLOGY, 2009, 44 (04) : 207 - 217