Comprehensive chronic laminar single-unit, multi-unit, and local field potential recording performance with planar single shank electrode arrays

被引:99
|
作者
Rozai, Takashi D. Y. [1 ,2 ,3 ]
Du, Zhanhong [1 ,2 ,3 ]
Gugel, Zhannetta V. [1 ,4 ]
Smith, Matthew A. [1 ,2 ,3 ,5 ]
Chase, Steven M. [2 ,6 ]
Bodily, Lance M. [7 ]
Caparosa, Ellen M. [7 ]
Friedlander, Robert M. [7 ]
Cui, X. Tracy [1 ,2 ,3 ]
机构
[1] Univ Pittsburgh, Bioengn, Pittsburgh, PA 15260 USA
[2] Ctr Neural Basis Cognit, Pittsburgh, PA USA
[3] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15260 USA
[4] CALTECH, Div Biol & Biol Engn, Pasadena, CA 91125 USA
[5] Univ Pittsburgh, Ophthalmol, Pittsburgh, PA 15260 USA
[6] Carnegie Mellon Univ, Biomed Engn, Pittsburgh, PA 15213 USA
[7] Univ Pittsburgh, Neurol Surg, Pittsburgh, PA 15260 USA
关键词
Electrophysiology; Microelectrode arrays; Gamma oscillations; Firing rate; Power density spectra; Electrochemical impedance spectroscopy; Signal-to-noise; Visual evoked activity; Visual cortex; FAST-SPIKING INTERNEURONS; BRAIN-COMPUTER INTERFACE; VISUAL-CORTEX; ELECTROCHEMICAL DEPOSITION; FREQUENCY-SELECTIVITY; CONTROLLED-RELEASE; CEREBRAL-ISCHEMIA; RECEPTIVE-FIELDS; NEURAL PROBES; AREAS V1;
D O I
10.1016/j.jneumeth.2014.12.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Intracortical electrode arrays that can record extracellular action potentials from small, targeted groups of neurons are critical for basic neuroscience research and emerging clinical applications. In general, these electrode devices suffer from reliability and variability issues, which have led to comparative studies of existing and emerging electrode designs to optimize performance. Comparisons of different chronic recording devices have been limited to single-unit (SU) activity and employed a bulk averaging approach treating brain architecture as homogeneous with respect to electrode distribution. New method: In this study, we optimize the methods and parameters to quantify evoked multi-unit (MU) and local field potential (LFP) recordings in eight mice visual cortices. Results: These findings quantify the large recording differences stemming from anatomical differences in depth and the layer dependent relative changes to SU and MU recording performance over 6-months. For example, performance metrics in Layer V and stratum pyramidale were initially higher than Layer but decrease more rapidly. On the other hand, Layer II/III maintained recording metrics longer. In addition, chronic changes at the level of layer IV are evaluated using visually evoked current source density. Comparison with existing method(s): The use of MU and LFP activity for evaluation and tracking biological depth provides a more comprehensive characterization of the electrophysiological performance landscape of microelectrodes. Conclusions: A more extensive spatial and temporal insight into the chronic electrophysiological performance over time will help uncover the biological and mechanical failure mechanisms of the neural electrodes and direct future research toward the elucidation of design optimization for specific applications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 40
页数:26
相关论文
共 50 条
  • [21] Evaluation of the spatial resolution of electrode arrays for suprachoroidal retinal prosthesis by recording single-unit activities in the lateral geniculate nucleus
    Kanda, Hiroyuki
    Miyoshi, Tomomitsu
    Morimoto, Takeshi
    Fujikado, Takashi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [22] Predicting Single-Unit Activity from Local Field Potentials with LSTMs
    Savolainen, Oscar W.
    Constandinou, Timothy G.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 884 - 887
  • [23] Prediction methods for the damping effect of multi-unit particle dampers based on the cyclic iterations of a single-unit particle damper
    Wang, Yanrong
    Liu, Bin
    Tian, Aimei
    Wei, Dangsheng
    Jiang, Xianghua
    JOURNAL OF SOUND AND VIBRATION, 2019, 443 : 341 - 361
  • [24] Tetrodes markedly improve the reliability and yield of multiple single-unit isolation from multi-unit recordings in cat striate cortex
    Gray, CM
    Maldonado, PE
    Wilson, M
    McNaughton, B
    JOURNAL OF NEUROSCIENCE METHODS, 1995, 63 (1-2) : 43 - 54
  • [25] Multiple single-unit recordings from the CNS using thin-film electrode arrays
    Carter, Randy R.
    Houk, James C.
    IEEE Transactions on Rehabilitation Engineering, 1993, 3 (02): : 175 - 184
  • [26] A Radiographic Evaluation of Graft Height Changes after Maxillary Sinus Augmentation according to Single-unit Implants and Multi-unit Implants
    Park, Mi Jung
    Kim, Myung-Rae
    Kim, Ji-Youn
    Kim, Ye-Mi
    Kim, Sun-Jong
    EWHA MEDICAL JOURNAL, 2012, 35 (01): : 26 - 31
  • [27] Robust, highly customizable, and economical multi-channel electrode for chronic multi-unit recording in behaving animals
    Tateyama, Yukina
    Oyama, Kei
    Shiraishi, Masaru
    Iijima, Toshio
    Tsutsui, Ken-Ichiro
    NEUROSCIENCE RESEARCH, 2017, 125 : 54 - 59
  • [28] SWEET NEW MULTIPLE ELECTRODE FOR CHRONIC SINGLE UNIT RECORDING IN MOVING ANIMALS
    CHOROVER, SL
    DELUCA, AM
    PHYSIOLOGY & BEHAVIOR, 1972, 9 (04) : 671 - 674
  • [29] ISO-ORIENTED AND CROSS-ORIENTED COLUMNS IN CAT STRIATE CORTEX - A STUDY WITH SIMULTANEOUS SINGLE-UNIT AND MULTI-UNIT RECORDINGS
    BAUER, R
    ECKHORN, R
    JORDAN, W
    NEUROSCIENCE, 1989, 30 (03) : 733 - 740
  • [30] Effect of Eye Opening on Single-Unit Activity and Local Field Potentials in the Subthalamic Nucleus
    Chockalingam, Arun
    Belasen, Abigail
    Chen, Nita
    Ramirez-Zamora, Adolfo
    Youn, Youngwon
    Feustel, Paul
    Wilock, Meghan E.
    Shin, Damian S.
    Pilitsis, Julie G.
    NEUROMODULATION, 2017, 20 (05): : 471 - 477