Comprehensive chronic laminar single-unit, multi-unit, and local field potential recording performance with planar single shank electrode arrays

被引:99
|
作者
Rozai, Takashi D. Y. [1 ,2 ,3 ]
Du, Zhanhong [1 ,2 ,3 ]
Gugel, Zhannetta V. [1 ,4 ]
Smith, Matthew A. [1 ,2 ,3 ,5 ]
Chase, Steven M. [2 ,6 ]
Bodily, Lance M. [7 ]
Caparosa, Ellen M. [7 ]
Friedlander, Robert M. [7 ]
Cui, X. Tracy [1 ,2 ,3 ]
机构
[1] Univ Pittsburgh, Bioengn, Pittsburgh, PA 15260 USA
[2] Ctr Neural Basis Cognit, Pittsburgh, PA USA
[3] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15260 USA
[4] CALTECH, Div Biol & Biol Engn, Pasadena, CA 91125 USA
[5] Univ Pittsburgh, Ophthalmol, Pittsburgh, PA 15260 USA
[6] Carnegie Mellon Univ, Biomed Engn, Pittsburgh, PA 15213 USA
[7] Univ Pittsburgh, Neurol Surg, Pittsburgh, PA 15260 USA
关键词
Electrophysiology; Microelectrode arrays; Gamma oscillations; Firing rate; Power density spectra; Electrochemical impedance spectroscopy; Signal-to-noise; Visual evoked activity; Visual cortex; FAST-SPIKING INTERNEURONS; BRAIN-COMPUTER INTERFACE; VISUAL-CORTEX; ELECTROCHEMICAL DEPOSITION; FREQUENCY-SELECTIVITY; CONTROLLED-RELEASE; CEREBRAL-ISCHEMIA; RECEPTIVE-FIELDS; NEURAL PROBES; AREAS V1;
D O I
10.1016/j.jneumeth.2014.12.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Intracortical electrode arrays that can record extracellular action potentials from small, targeted groups of neurons are critical for basic neuroscience research and emerging clinical applications. In general, these electrode devices suffer from reliability and variability issues, which have led to comparative studies of existing and emerging electrode designs to optimize performance. Comparisons of different chronic recording devices have been limited to single-unit (SU) activity and employed a bulk averaging approach treating brain architecture as homogeneous with respect to electrode distribution. New method: In this study, we optimize the methods and parameters to quantify evoked multi-unit (MU) and local field potential (LFP) recordings in eight mice visual cortices. Results: These findings quantify the large recording differences stemming from anatomical differences in depth and the layer dependent relative changes to SU and MU recording performance over 6-months. For example, performance metrics in Layer V and stratum pyramidale were initially higher than Layer but decrease more rapidly. On the other hand, Layer II/III maintained recording metrics longer. In addition, chronic changes at the level of layer IV are evaluated using visually evoked current source density. Comparison with existing method(s): The use of MU and LFP activity for evaluation and tracking biological depth provides a more comprehensive characterization of the electrophysiological performance landscape of microelectrodes. Conclusions: A more extensive spatial and temporal insight into the chronic electrophysiological performance over time will help uncover the biological and mechanical failure mechanisms of the neural electrodes and direct future research toward the elucidation of design optimization for specific applications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 40
页数:26
相关论文
共 50 条
  • [1] Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites
    Pothof, F.
    Bonini, L.
    Lanzilotto, M.
    Livi, A.
    Fogassi, L.
    Orban, G. A.
    Paul, O.
    Ruther, P.
    JOURNAL OF NEURAL ENGINEERING, 2016, 13 (04)
  • [2] Assessing neuronal coherence with single-unit, multi-unit, and local field potentials
    Zeitler, Magteld
    Fries, Pascal
    Gielen, Stan
    NEURAL COMPUTATION, 2006, 18 (09) : 2256 - 2281
  • [3] SINGLE-UNIT, MULTI-UNIT AND FIELD POTENTIAL RESPONSES IN THE STRIATE CORTEX OF MACAQUE AND CAT AS A FUNCTION OF CONTRAST
    KULIKOWSKI, JJ
    VIDYASAGAR, TR
    JOURNAL OF PHYSIOLOGY-LONDON, 1983, 334 (JAN): : P19 - P20
  • [4] An introspective examination of single-unit versus multi-unit franchisees
    Rajiv P. Dant
    Scott K. Weaven
    Brent L. Baker
    Hyo Jin (Jean) Jeon
    Journal of the Academy of Marketing Science, 2013, 41 : 473 - 496
  • [5] An introspective examination of single-unit versus multi-unit franchisees
    Dant, Rajiv P.
    Weaven, Scott K.
    Baker, Brent L.
    Jeon, Hyo Jin
    JOURNAL OF THE ACADEMY OF MARKETING SCIENCE, 2013, 41 (04) : 473 - 496
  • [6] AN INEXPENSIVE MICRODRIVE FOR CHRONIC SINGLE-UNIT RECORDING
    GOLDBERG, E
    MINERBO, G
    SMOCK, T
    BRAIN RESEARCH BULLETIN, 1993, 32 (03) : 321 - 323
  • [7] Erratum to: An introspective examination of single-unit versus multi-unit franchisees
    Rajiv P. Dant
    Scott K. Weaven
    Brent L. Baker
    Hyo Jin (Jean) Jeon
    Journal of the Academy of Marketing Science, 2013, 41 (4) : 497 - 500
  • [8] Single-unit neural recording with active microelectrode arrays
    Bai, Q
    Wise, KD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (08) : 911 - 920
  • [9] PERFORMANCE OF PLANAR MULTISITE MICROPROBES IN RECORDING EXTRACELLULAR SINGLE-UNIT INTRACORTICAL ACTIVITY
    DRAKE, KL
    WISE, KD
    FARRAYE, J
    ANDERSON, DJ
    BEMENT, SL
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (09) : 719 - 732
  • [10] Single-unit and multi-unit auction framework for peer-to-peer transactions
    Teixeira, Daniel
    Gomes, Luis
    Vale, Zita
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 133