Concentrations and Size Distributions of Particle Lung-deposited Surface Area (LDSA) in an Underground Mine

被引:13
|
作者
Salo, Laura [1 ]
Ronkko, Topi [1 ]
Saarikoski, Sanna [2 ]
Teinila, Kimmo [2 ]
Kuula, Joel [2 ]
Alanen, Jenni [1 ]
Arffman, Anssi [1 ,3 ]
Timonen, Hilkka [2 ]
Keskinen, Jorma [1 ]
机构
[1] Tampere Univ, Phys Unit, Aerosol Phys Lab, Tampere 33720, Finland
[2] Finnish Meteorol Inst, Atmospher Composit Res, Helsinki 00560, Finland
[3] Dekati Ltd, Kangasala 36240, Finland
基金
芬兰科学院;
关键词
Occupational exposure; Electrical particle sensor; Fine aerosol; Ultrafine aerosol; DIESEL PARTICULATE MATTER; AIR-POLLUTION; EXPOSURE; HEALTH; SENSORS; CARBON;
D O I
10.4209/aaqr.200660
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ultrafine particles produced by diesel-powered vehicles in underground mines are largely unaccounted for in mass-based air quality metrics. The Lung Deposited Surface Area concentration (LDSA) is an alternative to describe the harmfulness of particles. We aim to study concentrations and size distributions of LDSA at various locations in an underground mine as well as to evaluate the applicability of sensor-type measurement of LDSA. This study was conducted in an underground mine in Kemi, Finland, in 2017. Our main instrument was an electrical low-pressure impactor (ELPI+) inside a mobile laboratory. Additionally, five diffusion-charging based sensors were tested. The environment was challenging for the sensors as the particle size distribution was often outside the optimum range (20-300 nm) and dust accumulated inside the instruments. Despite this, the correlations with the ELPI+ were decent (R-2 from 0.53 to 0.59). With the ELPI+ we determined that the maintenance area had the lowest mean LDSA concentration (79 +/- 38 mu m(2) cm(-3)) of the measured locations. At the other locations, concentrations ranged from 137 to 405 mu m(2) cm(-3). The mode particle size for the LDSA distribution was around 100 nm at most locations, with the blasting site as a notable exception (mode size closer to 700 nm). Diffusion-charging based sensors-perhaps aided by optical sensors-are potential solutions for long-term monitoring of LDSA if dust accumulation is taken care of. Our research indicates worker exposure could be reduced with the implementation of a sensor network to show which locations need either protective gear or increased ventilation.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Accuracy of electrical aerosol sensors measuring lung deposited surface area concentrations
    Todea, Ana Maria
    Beckmann, Stefanie
    Kaminski, Heinz
    Asbach, Christof
    JOURNAL OF AEROSOL SCIENCE, 2015, 89 : 96 - 109
  • [32] Particle lung deposited surface area (LDSAal) size distributions in different urban environments and geographical regions: Towards understanding of the PM2.5 dose-response
    Lepisto, Teemu
    Lintusaari, Henna
    Oudin, Anna
    Barreira, Luis M. F.
    Niemi, Jarkko, V
    Karjalainen, Panu
    Salo, Laura
    Silvonen, Ville
    Markkula, Lassi
    Hoivala, Jussi
    Marjanen, Petteri
    Martikainen, Sampsa
    Aurela, Minna
    Reyes, Felipe Reyes
    Oyola, Pedro
    Kuuluvainen, Heino
    Manninen, Hanna E.
    Schins, Roel P. F.
    Vojtisek-Lom, Michal
    Ondracek, Jakub
    Topinka, Jan
    Timonen, Hilkka
    Jalava, Pasi
    Saarikoski, Sanna
    Ronkko, Topi
    ENVIRONMENT INTERNATIONAL, 2023, 180
  • [33] Threshold pressure for infiltration and particle specific surface area of particle compacts with bimodal size distributions
    Molina, JM
    Arpón, R
    Saravanan, RA
    García-Cordovilla, C
    Louis, E
    Narciso, J
    SCRIPTA MATERIALIA, 2004, 51 (06) : 623 - 627
  • [34] Size distribution and lung-deposited doses of particulate matter from household exposure to biomass smoke
    Nicolaou, Laura
    Fandino-Del-Rio, Magdalena
    Koehler, Kirsten
    Checkley, William
    INDOOR AIR, 2021, 31 (01) : 51 - 62
  • [35] PARTICLE-SIZE DISTRIBUTIONS IN UNDERGROUND COAL-MINES
    BURKHART, JE
    MCCAWLEY, MA
    WHEELER, RW
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (02): : 122 - 126
  • [36] Passive aerosol sampler for particle concentrations and size distributions
    Whitehead, Todd
    Leith, David
    JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (03): : 331 - 335
  • [37] Variation of field strength in underground mine area on the size of VLF loop antennas laid on the earth surface
    Gogoi, AK
    Raghuram, R
    IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM 1997, VOLS 1-4, 1997, : 1792 - 1795
  • [38] On-site investigation of the concentrations and size distributions of bioaerosols in the underground garages
    Xing, Yan
    Li, Yanpeng
    Zhang, Ke
    Liu, Daiyi
    Zhang, Gaoshan
    Zhao, Luyao
    ATMOSPHERIC POLLUTION RESEARCH, 2023, 14 (07)
  • [39] Personal exposure to gaseous and particulate phase polycyclic aromatic hydrocarbons (PAHs) and nanoparticles and lung deposited surface area (LDSA) for soot among Norwegian chimney sweepers
    Moazami, Therese Nitter
    Jorgensen, Rikke Bramming
    Svendsen, Kristin v Hirsch
    Teigen, Krister Aune
    Hegseth, Marit Nost
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2024, 21 (01) : 24 - 34
  • [40] COMBINED MEASUREMENTS OF PARTICLE VELOCITIES, SIZE DISTRIBUTIONS, AND CONCENTRATIONS - REVIEW
    DURST, F
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (03): : 284 - 296