Concentrations and Size Distributions of Particle Lung-deposited Surface Area (LDSA) in an Underground Mine

被引:13
|
作者
Salo, Laura [1 ]
Ronkko, Topi [1 ]
Saarikoski, Sanna [2 ]
Teinila, Kimmo [2 ]
Kuula, Joel [2 ]
Alanen, Jenni [1 ]
Arffman, Anssi [1 ,3 ]
Timonen, Hilkka [2 ]
Keskinen, Jorma [1 ]
机构
[1] Tampere Univ, Phys Unit, Aerosol Phys Lab, Tampere 33720, Finland
[2] Finnish Meteorol Inst, Atmospher Composit Res, Helsinki 00560, Finland
[3] Dekati Ltd, Kangasala 36240, Finland
基金
芬兰科学院;
关键词
Occupational exposure; Electrical particle sensor; Fine aerosol; Ultrafine aerosol; DIESEL PARTICULATE MATTER; AIR-POLLUTION; EXPOSURE; HEALTH; SENSORS; CARBON;
D O I
10.4209/aaqr.200660
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ultrafine particles produced by diesel-powered vehicles in underground mines are largely unaccounted for in mass-based air quality metrics. The Lung Deposited Surface Area concentration (LDSA) is an alternative to describe the harmfulness of particles. We aim to study concentrations and size distributions of LDSA at various locations in an underground mine as well as to evaluate the applicability of sensor-type measurement of LDSA. This study was conducted in an underground mine in Kemi, Finland, in 2017. Our main instrument was an electrical low-pressure impactor (ELPI+) inside a mobile laboratory. Additionally, five diffusion-charging based sensors were tested. The environment was challenging for the sensors as the particle size distribution was often outside the optimum range (20-300 nm) and dust accumulated inside the instruments. Despite this, the correlations with the ELPI+ were decent (R-2 from 0.53 to 0.59). With the ELPI+ we determined that the maintenance area had the lowest mean LDSA concentration (79 +/- 38 mu m(2) cm(-3)) of the measured locations. At the other locations, concentrations ranged from 137 to 405 mu m(2) cm(-3). The mode particle size for the LDSA distribution was around 100 nm at most locations, with the blasting site as a notable exception (mode size closer to 700 nm). Diffusion-charging based sensors-perhaps aided by optical sensors-are potential solutions for long-term monitoring of LDSA if dust accumulation is taken care of. Our research indicates worker exposure could be reduced with the implementation of a sensor network to show which locations need either protective gear or increased ventilation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Analysis of Black Carbon (BC) concentration distribution in relation to Lung-Deposited Surface Area (LDSA) measured in the operational drift of the underground metalliferous mine
    Sabanov, Sergei
    Brune, Jurgen
    Wang, Liang
    Korshunova, Ruslana
    Qureshi, Abdullah R.
    Kuzembayev, Nursultan
    JOURNAL OF HAZARDOUS MATERIALS ADVANCES, 2025, 18
  • [2] Determination of total and lung-deposited particle surface area concentrations, in central Athens, Greece
    Stavros Cheristanidis
    Georgios Grivas
    Archontoula Chaloulakou
    Environmental Monitoring and Assessment, 2020, 192
  • [3] Determination of total and lung-deposited particle surface area concentrations, in central Athens, Greece
    Cheristanidis, Stavros
    Grivas, Georgios
    Chaloulakou, Archontoula
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2020, 192 (10)
  • [4] Source-oriented risk and lung-deposited surface area (LDSA) of ultrafine particles in a Southeast Asia urban area
    Chen, Tse-Lun
    Lai, Chen-Hao
    Chen, Yu-Cheng
    Ho, Yu-Hsuan
    Chen, Albert Y.
    Hsiao, Ta-Chih
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 870
  • [5] Spatiotemporal Heterogeneity of Lung-Deposited Surface Area in Zurich Switzerland: Lung-Deposited Surface Area as a New Routine Metric for Ambient Particle Monitoring
    Edebeli, Jacinta
    Spirig, Curdin
    Fluck, Stefan
    Fierz, Martin
    Anet, Julien
    INTERNATIONAL JOURNAL OF PUBLIC HEALTH, 2023, 68
  • [6] Comparison of Measured Particle Lung-Deposited Surface Area Concentrations by an Aerotrak 9000 Using Size Distribution Measurements for a Range of Combustion Aerosols
    Leavey, Anna
    Fang, Jiaxi
    Sahu, Manoranjan
    Biswas, Pratim
    AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (09) : 966 - 978
  • [7] Determining the count median diameter of nanoaerosols by simultaneously measuring their number and lung-deposited surface area concentrations
    Bau, S.
    Witschger, O.
    Gensdarmes, F.
    Thomas, D.
    JOURNAL OF NANOPARTICLE RESEARCH, 2013, 15 (12)
  • [8] Input-adaptive linear mixed-effects model for estimating alveolar lung-deposited surface area (LDSA) using multipollutant datasets
    Fung, Pak Lun
    Zaidan, Martha A.
    Niemi, Jarkko, V
    Saukko, Erkka
    Timonen, Hilkka
    Kousa, Anu
    Kuula, Joel
    Ronkko, Topi
    Karppinen, Ari
    Tarkoma, Sasu
    Kulmala, Markku
    Petaja, Tuukka
    Hussein, Tareq
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2022, 22 (03) : 1861 - 1882
  • [9] Determining the count median diameter of nanoaerosols by simultaneously measuring their number and lung-deposited surface area concentrations
    S. Bau
    O. Witschger
    F. Gensdarmes
    D. Thomas
    Journal of Nanoparticle Research, 2013, 15
  • [10] Determinants of aerosol lung-deposited surface area variation in an urban environment
    Reche, Cristina
    Viana, Mar
    Brines, Mariola
    Perez, Noemi
    Beddows, David
    Alastuey, Andres
    Querol, Xavier
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 517 : 38 - 47