Spectral analysis of scattered radiation in CT

被引:8
|
作者
Engel, Klaus J. [1 ]
Baeumer, Christian [1 ]
Wiegert, Jens [1 ]
Zeitler, Guenter [1 ]
机构
[1] Philips Res Europe, D-52066 Aachen, Germany
关键词
Computed Tomography; Spectral CT; X-ray radiation; scatter spectrum; spectral composition; scatter-to-primary ratio; anti-scatter grids; single and multiple scattered X-rays;
D O I
10.1117/12.771063
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the framework of Spectral Computed Tomography (Spectral CT), scattered X-ray radiation is examined for its spectral composition and spatial distribution by means of Monte Carlo simulations. A reliable material (e.g. bone / contrast agent) separation and quantification requires a precise knowledge of the transmitted X-ray spectrum especially for low energy photons. Unfortunately, for lower energies the primary intensity is increasingly covered by scattered radiation. The detected scattered radiation can be classified into two main categories with respect to their scattering history. The first category contains purely Rayleigh or one-time Compton scattered photons which typically have small scattering angles and an energy spectrum similar to that of the transmitted primary radiation. The second category comprises multiple Compton scattered photons with a spectral composition which is typically softer than that of the transmitted primary photons. In regions of strong beam attenuation (i.e. in the X-ray shadow of a scanned object), the scattered radiation is mainly composed of multiple Compton scattered photons. As a consequence, the spectrally resolved scatter-to-primary ratios strongly increase at low energies. High-quality anti-scatter grids can be used to reduce especially the detection of multiple Compton-scattered photons. A quantitative evaluation of measured photon energies below a certain limit between 30 keV and 50 keV (depending on the phantom geometry and the applied anti-scatter grid) is challenging, since primary photons are superposed by a significantly higher amount of scattered photons.
引用
收藏
页码:R9131 / R9131
页数:11
相关论文
共 50 条
  • [1] Experimental evaluation of the influence of scattered radiation on quantitative spectral CT imaging
    Sossin, Artur
    Rokni, Michal
    Brendel, Bernhard
    Daerr, Heiner
    Thran, Axel
    Erhard, Klaus
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [2] The width of the spectral lines of the Raman scattered radiation of benzene
    Gerlach, W
    ANNALEN DER PHYSIK, 1929, 1 (02) : 301 - 308
  • [3] An anthropomorphic study in evaluating scattered radiation at pediatric CT
    Wu, H
    Gallet, J
    MEDICAL PHYSICS, 2005, 32 (07) : 2415 - 2415
  • [4] Control of scattered radiation to personnel during fluoroscopic CT
    Nawfel, RD
    Judy, PF
    Silverman, SG
    Hooton, S
    Tuncali, K
    Adams, DF
    RADIOLOGY, 1998, 209P : 246 - 246
  • [5] REMOVING DEGENERATION IN X-RAY SPECTRAL ANALYSIS BY TAKING INTO ACCOUNT INTENSITY OF SCATTERED RADIATION
    BLOKHIN, MA
    DUIMAKAE.SI
    KARMANOV, VI
    INDUSTRIAL LABORATORY, 1965, 31 (12): : 1818 - &
  • [6] SPECTRAL FLUXES OF SCATTERED SOLAR-RADIATION IN ATMOSPHERE OF VENUS
    MELNIKOVA, IN
    IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1976, 12 (03): : 272 - 280
  • [7] Spectral analysis of red scattered sunlight at sunrise
    Zagury, F
    Fujii, M
    NEW ASTRONOMY, 2003, 8 (06): : 549 - 556
  • [8] SPECTRAL ANALYSIS OF LIGHT SCATTERED BY A TERNARY MIXTURE
    LEKKERKE.HN
    LAIDLAW, WG
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1974, 8 (06): : 1088 - 1097
  • [9] Analysis of scatter artifacts in cone-beam CT due to scattered radiation of metallic objects
    Iuso, Domenico
    Frysch, Robert
    Pfeiffer, Tim
    Rose, Georg
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [10] SPECTRAL ANALYSIS OF LIGHT SCATTERED FROM FLUIDS
    LEKKERKERKER, HN
    LAIDLAW, WG
    PHYSICAL REVIEW A, 1973, 7 (04) : 1332 - 1339