Fast-neutron source based on plasma-focus device

被引:0
|
作者
Scholz, M. [1 ]
Bienkowska, B. [1 ]
Chernyshova, M. [1 ]
Gribkov, V. A. [1 ]
Jednorog, S. [1 ]
Kalinowska, Z. [1 ]
Karpinski, L. [1 ]
Paduch, M. [1 ]
Prokopowicz, R. [1 ]
Szydlowski, A. [2 ]
机构
[1] IPPLM, 23 Hery Str, PL-01497 Warsaw, Poland
[2] Andrzej Soltan Inst Nucl Studies IPJ, PL-05400 Otwock, Poland
来源
PLASMA 2007 | 2008年 / 993卷
关键词
plasma focus; gamma spectrometry; Monte Carlo calculations;
D O I
暂无
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
This paper describes investigations of neutrons produced by small plasma focus device PF-6 operating in the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland. Main parameters of neutron radiation have been measured by scintillation probe, and by activation technique. Current derivative probe has also been applied to measure dI/dt signal. Simultaneously neutron transport calculations have been carried out by Monte Carlo method. Finally, experimental measurements and numerical calculations have allowed concluding that plasma focus devices can be useful pulse neutron sources for different applications.
引用
收藏
页码:345 / +
页数:2
相关论文
共 50 条
  • [31] A new fast-neutron source for radiobiological research
    Wolber, G
    Hoever, KH
    Krauss, O
    MaierBorst, W
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (04): : 725 - 733
  • [32] PLASMA-FOCUS X-RAY SOURCE FOR LITHOGRAPHY
    KATO, Y
    OCHIAI, I
    WATANABE, Y
    MURAYAMA, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1988, 6 (01): : 195 - 198
  • [33] FAST-NEUTRON SOURCE FOR CULTURED CELL IRRADIATION
    PRIOR, RM
    MOSS, AJ
    ERICHSEN, EA
    EASON, CS
    BAKER, ML
    DALRYMPLE, GV
    RADIOLOGY, 1976, 119 (02) : 463 - 465
  • [34] FAST-NEUTRON SOURCE FOR CULTURED CELL IRRADIATION
    PRIOR, RM
    MOSS, AJ
    BAKER, ML
    DALRYMPLE, GV
    WILLIAMS.FS
    RADIATION RESEARCH, 1974, 59 (01) : 121 - 122
  • [35] PROSPECTS OF A PLASMA-FOCUS DEVICE AS AN INTENSE X-RAY SOURCE FOR FINE LINE LITHOGRAPHY
    KUYEL, B
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 275 : 44 - 51
  • [36] EFFECT OF ELECTRODE MATERIALS ON THE NEUTRON EMISSION FROM A PLASMA-FOCUS
    ROUT, RK
    SHYAM, A
    CHITRA, V
    ANNALS OF NUCLEAR ENERGY, 1991, 18 (06) : 357 - 358
  • [37] DETERMINATION OF THE REGION OF NEUTRON GENERATION IN BUBBLE CHAMBERS WITH A PLASMA-FOCUS
    TRUSILLO, SV
    GUZHOVSKII, BY
    MAKEEV, NG
    TSUKERMAN, VA
    JETP LETTERS, 1981, 33 (03) : 140 - 143
  • [38] Palm top plasma focus device as a portable pulsed neutron source
    Rout, R. K.
    Niranjan, Ram
    Mishra, P.
    Srivastava, R.
    Rawool, A. M.
    Kaushik, T. C.
    Gupta, Satish C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (06):
  • [39] MEASUREMENTS OF HIGH-ENERGY DEUTERONS IN PLASMA-FOCUS DEVICE
    GULLICKSON, RL
    SAHLIN, HL
    JOURNAL OF APPLIED PHYSICS, 1978, 49 (03) : 1099 - 1105
  • [40] Electrical Behavior of an Ultralow-Energy Plasma-Focus Device
    Oscar Barbaglia, Mario
    Bruzzone, Horacio
    Nestor Acuna, Hugo
    Soto, Leopoldo
    Clausse, Alejandro
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (01) : 138 - 142