Accuracy and repeatability of a pressure measurement system in the patellofemoral joint

被引:75
|
作者
Wilson, DR
Apreleva, MV
Eichler, MJ
Harrold, FR
机构
[1] Beth Israel Deaconess Med Ctr, Orthopaed Biomech Lab, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
pressure; force; contact; accuracy; patellofemoral joint; measurement; biomechanics;
D O I
10.1016/S0021-9290(03)00105-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objective of this study was to assess how accurately and repeatably the Iscan system measures force and pressure in the natural patellofemoral joint. These measurements must be made to test widely held assumptions about the relationships between mechanics, pain and cartilage degeneration. We assessed the system's accuracy by using test rigs in a materials testing machine to apply known forces and force distributions across the sensor. The root mean squared error in measuring resultant force (for five trials at each of seven load levels) was 6.5 +/- 4.4% (mean+/-standard deviation over all trials at all load levels), while the absolute error was -5.5+/-5.6%. For force distribution, the root mean squared error (for five trials at each of five force distributions) was 0.86+/-0.58%, while the absolute error was -0.22+/-1.03%. We assessed the repeatability of the system's measurements of patellofemoral contact force, pressure and force distribution in four cadaver specimens loaded in continuous and static flexion. Variability in measurement (standard deviation expressed as a percentage of the mean) was 9.1% for resultant force measurements and 3.0% for force distribution measurements for static loads, and 7.3% for resultant force and 2.2% for force distribution measurements for continuous flexion. Cementing the sensor to the cartilage lowered readings of resultant force by 31+/-32% (mean+/-standard deviation), area by 24+/-13% and mean pressure by 9+/-34% (relative to the uncemented sensor). Maximum pressure measurement, however, was 24+/-43% higher in the cemented sensor than in the uncemented sensor. The results suggest that the sensor measures force distribution more accurately and repeatably than absolute force. A limitation of our work, however, is that the sensor must be cemented to the patellar articular surface to make the force distribution measurements, and our results suggest that this process reduces the accuracy of force, pressure and area measurements. Our results suggest that the Iscan system's pressure measurement accuracy and repeatability are comparable to that of Fuji Prescale film, but its advantages are that it is thinner than most Fuji Prescale film, it measures contact area more accurately and that it makes continuous measurements of force, pressure and area. (C) 2003 Published by Elsevier Science Ltd.
引用
收藏
页码:1909 / 1915
页数:7
相关论文
共 50 条
  • [21] Patellofemoral Joint
    Fink, C.
    Benedetto, K. P.
    [J]. ARTHROSKOPIE, 2005, 18 (04) : 281 - 281
  • [22] Patellofemoral Joint
    Schoettle, P. B.
    Biedert, R. M.
    [J]. ARTHROSKOPIE, 2010, 23 (03) : 163 - 163
  • [23] Patellofemoral Joint
    El Attal, R.
    Dirisamer, F.
    [J]. ARTHROSKOPIE, 2020, 33 (06) : 403 - 403
  • [24] THE PATELLOFEMORAL JOINT
    PARIENTY, R
    [J]. RADIOLOGY, 1981, 140 (01) : 248 - 248
  • [25] RADIO-ANATOMIC POSITION FOR JOINT SPACE WIDTH MEASUREMENT OF THE HUMAN PATELLOFEMORAL JOINT
    SZEBENYI, B
    BUCKLANDWRIGHT, C
    DIEPPE, PA
    [J]. BRITISH JOURNAL OF RHEUMATOLOGY, 1993, 32 : 50 - 50
  • [26] Repeatability, Reproducibility, and Accuracy of a Novel Pushbroom Hyperspectral System
    Vilaseca, Meritxell
    Schael, Barbara
    Delpueyo, Xana
    Chorro, Elisabet
    Perales, Esther
    Hirvonen, Tapani
    Pujol, Jaume
    [J]. COLOR RESEARCH AND APPLICATION, 2014, 39 (06): : 549 - 558
  • [27] Accuracy and repeatability of the Orbscan corneal topography system.
    Beyrouthy, M
    Brunette, I
    Horner, D
    Munger, R
    Demers, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S895 - S895
  • [28] BLAST PRESSURE MEASUREMENT ACCURACY
    MELICHAR, JF
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1968, 152 (A1) : 700 - &
  • [29] Pressure pain thresholds in adults with patellofemoral pain and patellofemoral joint osteoarthritis: a case-control study
    Bartholomew, Clare
    Edwards, Laura
    Lack, Simon
    [J]. SCANDINAVIAN JOURNAL OF PAIN, 2019, 19 (04) : 713 - 723
  • [30] Dynamic measurement of patellofemoral contact pressure following reconstruction of the medial patellofemoral ligament:: An in vitro study
    Ostermeier, Sven
    Holst, Marc
    Bohnsack, Michael
    Hurschler, Christof
    Stukenborg-Colsman, Christina
    Wirth, Carl-Joachim
    [J]. CLINICAL BIOMECHANICS, 2007, 22 (03) : 327 - 335