Inertial Sensor based System for Upper Limb Motion Quantification

被引:0
|
作者
Dumpis, Martynas [1 ]
Gedminas, Dovydas [1 ]
Serackis, Arturas [1 ]
机构
[1] Vilnius Gediminas Tech Univ, Dept Elect Syst, Vilnius, Lithuania
关键词
motion sensor; kalman filter; rehabilitation; upper limb tracking; quantification;
D O I
10.1109/ESTREAM56157.2022.9781729
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper focuses on the quantification of upper limb motion during human-operated exercises, dedicated to rehabilitation. Continuous tracking of a measurement of each exercise helps the patient individually monitor the current progress of rehabilitation treatment and provide a source of quantified data for the preparation of biological feedback. While the camera-based solutions may provide more precise upper limb tracking, such systems may cause some privacy issues or might be uncomfortable for the patient to use in daily manner. The sensor-based solution is a good option here. Inertial sensors In this investigation, an algorithm for automated calibration of a single sensor with precise estimation of upper limb movement is presented. The study focuses on the measurement of rehabilitation exercises and the collection of parameters that are important to medical diagnosis and long-term monitoring of the change in these parameters. The suggested solution simplifies the human motion estimation process by correctly estimating human motion even inertial sensor's axis is not aligned correctly with the body frame. Additionally, a system with two sensors is proposed to compensate for upper limb movement quantification uncertainty during specific exercises.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] The motion measurement of human upper limb based on electromagnetic tracking system
    Zhang Jianguo
    Song Haiyan
    Wang Li
    [J]. Proceedings of the International Conference on Mechanical Transmissions, Vols 1 and 2, 2006, : 1559 - 1561
  • [22] An integrated upper limb motion analysis system
    Nazeran, H
    Jaberzadeh, S
    [J]. IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 479 - 480
  • [23] A review of motion capture systems for upper limb motion in throwing events: Inertial measurement unit
    Noh, S. F. A. Ahmad
    Baharudin, M. E.
    Nor, A. Mohd
    Saad, Mohd Sazli
    Zakaria, Mohd Zakimi
    [J]. 6TH INTERNATIONAL CONFERENCE ON APPLICATIONS AND DESIGN IN MECHANICAL ENGINEERING, 2019, 670
  • [24] An Adaptive Complementary Filter for Inertial Sensor Based Data Fusion to Track Upper Body Motion
    Karunarathne, M. Sajeewani
    Ekanayake, Samitha W.
    Pathirana, Pubudu N.
    [J]. 2014 7TH INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION FOR SUSTAINABILITY (ICIAFS), 2014,
  • [25] An inertial human upper limb motion tracking method for robot programming by demonstration
    Pellois, Robin
    Bruls, Olivier
    [J]. ROBOTICS AND AUTONOMOUS SYSTEMS, 2022, 156
  • [26] Accuracy of Base of Support Using an Inertial Sensor Based Motion Capture System
    Guo, Liangjie
    Xiong, Shuping
    [J]. SENSORS, 2017, 17 (09)
  • [27] TORQUE ANALYSIS OF LOWER LIMB BASED ON UDWADIA-KALABA APPROACH AND INERTIAL SENSOR MOTION DETECTION
    Qin, Feifei
    Zhao, Han
    Zhen, Shengchao
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2020, 20 (04)
  • [28] A wearable inertial sensor system for human motion analysis
    Liu, T
    Inoue, Y
    Shibata, K
    Tang, XY
    [J]. 2005 IEEE INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE IN ROBOTICS AND AUTOMATION, PROCEEDINGS, 2005, : 409 - 413
  • [29] Study on Motion Measurement of Human Upper Limb Based on Electromagnetic Tracking System
    Zhang, Jianguo
    Song, Haiyan
    Xue, Qiang
    [J]. IEEM: 2008 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1-3, 2008, : 768 - +
  • [30] A Upper Limb Rehabilitation System with Motion Intention Detection
    Su, Yanyu
    Wu, Yan
    Gao, Yongzhuo
    Dong, Wei
    Sun, Yixuan
    Du, Zhijiang
    [J]. 2017 2ND INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM), 2017, : 510 - 516