The pressurization transient analysis for Lungmen advanced boiling water reactor using RETRAN-02

被引:4
|
作者
Tsai, Chiung-Wen [1 ]
Shih, Chunkuan [1 ,2 ]
Wang, Jong-Rong [3 ]
Lin, Hao-Tzu [3 ]
Cheng, Su-Chin [4 ]
机构
[1] Natl Tsing Hua Univ, Dept Engn & Syst Sci, Hsinchu 30013, Taiwan
[2] Natl Tsing Hua Univ, Inst Nucl Engn & Sci, Hsinchu 30013, Taiwan
[3] Inst Nucl Energy Res, Longtan Township 32546, Taoyuan County, Taiwan
[4] Taiwan Power Co, Dept Nucl Engn, Taipei 10016, Taiwan
关键词
ABWR; Lungmen; RETRAN; Safety analysis; Pressure increase transient;
D O I
10.1016/j.nucengdes.2010.04.040
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A RETRAN-02 model was devised and benchmarked against the preliminary safety analysis report (PSAR) for the Lungmen nuclear power plant roughly 10 years ago. During these years, the fuel design, some of the reactor vessel designs, and control systems have since been revised. The Lungmen RETRAN-02 model has also been modified with updated information when available. This study uses the analytical results of the final safety analysis report (FSAR) to benchmark the Lungmen RETRAN-02 plant model. Five transients, load rejection (LR), turbine trip (TT), main steam line isolation valves closure (MSIVC), loss of feedwater flow (LOFF), and one turbine control valve closure (OTCVC), were utilized to validate the Lungmen RETRAN-02 model. Moreover, due to the strong coupling effect between neutron dynamics and the thermal-hydraulic response during pressurization of transients, the one-dimensional kinetic model with the cross-section data library is used to simulate the coupling effect. The analytical results show good agreement in trends between the RETRAN-02 calculation and the Lungmen FSAR data. Based on the benchmark of these design-basis transients, the modified Lungmen RETRAN-02 model has been adjusted to a level of confidence for analysis of pressure increase transients. Analytical results indicate that the Lungmen advanced boiling water reactor (ABWR) design satisfied design criteria, i.e., vessel pressure and hot shutdown capability. However, a slight difference exists in the simulation of the water level for cases with changes in water levels. The Lungmen RETRAN-02 model tends to predict the change in water level at a slower rate than that in the Lungmen FSAR. There is also a slight difference in void reactivity response toward vessel pressure change in both simulations, which causes the calculated neutron flux before reactor shutdown to differ to some degree when the reactor experiences a rapid pressure increase. Further studies will be performed in the future using Lungmen startup test data. (C) 2010 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:3037 / 3045
页数:9
相关论文
共 50 条
  • [41] CURRENT STATUS OF ADVANCED BOILING WATER REACTOR (ABWR).
    Takashima, Yoshie
    Arai, Toshiharu
    Hitachi Review, 1984, 33 (06): : 299 - 306
  • [42] ADVANCED BOILING WATER-REACTOR MATERIALS TECHNOLOGY
    SANDUSKY, DW
    OKADA, T
    SAITO, T
    MATERIALS PERFORMANCE, 1990, 29 (01) : 66 - 71
  • [44] ANTICIPATED TRANSIENT WITHOUT SCRAM ANALYSIS FOR AN ABWR USING RETRAN
    Tsai, Chiung-Wen
    Yang, Shu-Ming
    Shih, Chunkuan
    Wang, Jong-Rong
    Ma, Shao-Shih
    Cheng, Su-Chin
    ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 3, 2008, : 775 - 781
  • [45] Digital instrumentation and control failure events derivation and analysis for Advanced Boiling Water Reactor
    Huang, Hui-Wen
    Yang, Wei-Yi
    Shih, Chunkuan
    Yih, Swu
    Chen, Yi-Bin
    Tzeng, Yen-Chang
    Kuo, Cherng-Tsong
    Chuang, Chan-Fu
    Chen, Ming-Huei
    Yu, an-Chang Yu
    Wang, Li-Hsin
    Wang, Hsun-Ho
    Chen, Chun-Yu
    Tu, Wan-Tsz
    DEPCOS-RELCOMEX 2006, 2006, : 327 - +
  • [46] Advanced Boiling Water Reactor Core Performance Calculations.
    Lemke, Heinz Dieter
    Pleuger, Dieter
    Schmidt, Uwe
    Atomkernenergie, Kerntechnik, 1982, 41 (03): : 200 - 202
  • [47] ADVANCED BOILING WATER-REACTOR CORE PERFORMANCE CALCULATIONS
    LEMKE, HD
    PLEUGER, D
    SCHMIDT, U
    ATOMKERNENERGIE-KERNTECHNIK, 1982, 41 (03): : 200 - 202
  • [48] Investigation of a passive condenser system of an advanced boiling water reactor
    Oh, Seungmin
    Gao, Haijing
    Revankar, Shripad T.
    NUCLEAR TECHNOLOGY, 2007, 158 (02) : 208 - 218
  • [49] Local dynamic analysis in boiling water reactor
    Polo-Labarrios, M. A.
    Franco-Perez, L.
    Quezada-Tellez, L. A.
    Fernandez-Anaya, G.
    ANNALS OF NUCLEAR ENERGY, 2020, 137 (137)
  • [50] BOILING WATER REACTOR SYSTEM ANALYSIS.
    Shiralkar, Bharat S.