The pressurization transient analysis for Lungmen advanced boiling water reactor using RETRAN-02

被引:4
|
作者
Tsai, Chiung-Wen [1 ]
Shih, Chunkuan [1 ,2 ]
Wang, Jong-Rong [3 ]
Lin, Hao-Tzu [3 ]
Cheng, Su-Chin [4 ]
机构
[1] Natl Tsing Hua Univ, Dept Engn & Syst Sci, Hsinchu 30013, Taiwan
[2] Natl Tsing Hua Univ, Inst Nucl Engn & Sci, Hsinchu 30013, Taiwan
[3] Inst Nucl Energy Res, Longtan Township 32546, Taoyuan County, Taiwan
[4] Taiwan Power Co, Dept Nucl Engn, Taipei 10016, Taiwan
关键词
ABWR; Lungmen; RETRAN; Safety analysis; Pressure increase transient;
D O I
10.1016/j.nucengdes.2010.04.040
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A RETRAN-02 model was devised and benchmarked against the preliminary safety analysis report (PSAR) for the Lungmen nuclear power plant roughly 10 years ago. During these years, the fuel design, some of the reactor vessel designs, and control systems have since been revised. The Lungmen RETRAN-02 model has also been modified with updated information when available. This study uses the analytical results of the final safety analysis report (FSAR) to benchmark the Lungmen RETRAN-02 plant model. Five transients, load rejection (LR), turbine trip (TT), main steam line isolation valves closure (MSIVC), loss of feedwater flow (LOFF), and one turbine control valve closure (OTCVC), were utilized to validate the Lungmen RETRAN-02 model. Moreover, due to the strong coupling effect between neutron dynamics and the thermal-hydraulic response during pressurization of transients, the one-dimensional kinetic model with the cross-section data library is used to simulate the coupling effect. The analytical results show good agreement in trends between the RETRAN-02 calculation and the Lungmen FSAR data. Based on the benchmark of these design-basis transients, the modified Lungmen RETRAN-02 model has been adjusted to a level of confidence for analysis of pressure increase transients. Analytical results indicate that the Lungmen advanced boiling water reactor (ABWR) design satisfied design criteria, i.e., vessel pressure and hot shutdown capability. However, a slight difference exists in the simulation of the water level for cases with changes in water levels. The Lungmen RETRAN-02 model tends to predict the change in water level at a slower rate than that in the Lungmen FSAR. There is also a slight difference in void reactivity response toward vessel pressure change in both simulations, which causes the calculated neutron flux before reactor shutdown to differ to some degree when the reactor experiences a rapid pressure increase. Further studies will be performed in the future using Lungmen startup test data. (C) 2010 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:3037 / 3045
页数:9
相关论文
共 50 条
  • [1] Pressurization transient analyses of the Lungmen ABWR plant using RETRAN-02
    Tzang, Yih-Chyun
    Chiang, Ray-Feng
    Yuan, Yng-Ruey
    Ferng, Yuh-Ming
    Pei, Bau-Shei
    NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (04) : 868 - 879
  • [2] QUALIFICATION OF A RETRAN-02 MODEL FOR BOILING WATER-REACTOR TRANSIENT ANALYSIS
    GARRETT, ME
    FORKNER, SL
    KEYS, TA
    PERRY, GW
    WADDELL, MW
    NUCLEAR TECHNOLOGY, 1983, 61 (02) : 276 - 295
  • [3] Full-load-rejection design analysis for the Lungmen advanced boiling water reactor using RETRAN
    Tang, JR
    Kao, LS
    Wang, JR
    Yuann, RY
    NUCLEAR TECHNOLOGY, 2000, 129 (01) : 51 - 68
  • [4] The design assessment of limiting transient event by RETRAN-02 and VIPRE-01 for Lungmen ABWR
    Tsai, Chiung-Wen
    Shih, Chunkuan
    Wang, Jong-Rong
    Cheng, Su-Chin
    NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (03) : 942 - 949
  • [5] PREDICTION OF GE-ATLAS TRANSIENT BOILING TRANSITION DATA USING RETRAN-02 RETRAN-15F
    ANSARI, AAF
    BURNS, KJ
    BELLER, DK
    HAQUE, QA
    SCHULTZ, SP
    NUCLEAR TECHNOLOGY, 1983, 61 (02) : 205 - 211
  • [6] PREDICTION OF GE-ATLAS TRANSIENT BOILING TRANSITION DATA USING RETRAN-02/RETRAN-15F.
    Ansari, A.A.Farooq
    Burns, Kevin J.
    Beller, Douglas K.
    Haque, Quazi A.
    Schultz, Stephen P.
    Nuclear Technology, 1983, 16 (03) : 205 - 211
  • [7] APPLICATION OF RETRAN-02 TO PLANT TRANSIENT ANALYSIS AND ISSUE RESOLUTION
    ALONSO, PM
    CARRASCO, RO
    SEDANO, PG
    NUCLEAR TECHNOLOGY, 1991, 93 (01) : 7 - 15
  • [8] Pressurized water reactor coolant pump locked rotor analysis methodology using RETRAN-02 and FREY
    Kao, L
    Huang, PH
    NUCLEAR TECHNOLOGY, 1999, 127 (03) : 382 - 388
  • [9] IMPROVED PRESSURIZED WATER-REACTOR STEAMLINE BREAK ANALYSIS USING RETRAN-02, ARROTTA, AND VIPRE-02
    DIAS, AF
    EISENHART, LD
    BELL, DM
    GARRETT, TJ
    NEISES, GJ
    AGEE, LJ
    NUCLEAR TECHNOLOGY, 1992, 100 (02) : 193 - 202
  • [10] AN ANALYSIS OF THE CHERNOBYL ACCIDENT USING RETRAN-02/MOD3
    CHAO, J
    CHEXAL, VK
    LAYMAN, WH
    VINE, G
    JENSEN, PJ
    DASTUR, AR
    NUCLEAR TECHNOLOGY, 1988, 83 (03) : 289 - 301