Comparison of ultrasonographic cervical length and the Bishop score in predicting successful labor induction

被引:37
|
作者
Gomez Laencina, Ana M. [1 ]
Garcia Sanchez, Francisco
Herrera Gimenez, Javier
Solera Martinez, Montserrat
Valverde Martinez, Jorge Arturo
Martinez Vizcaino, Vicente
机构
[1] Hosp Virgen Luz, Serv Ginecol & obstet, Cuenca, Spain
[2] Hosp Virgen Arrixaca, Serv Gynecol & Obstet, Murcia, Spain
[3] Univ Castilla La Mancha, Social & Hlth Res Ctr, Cuenca, Spain
关键词
transvaginal ultrasonography; cervical length; Bishop score; induction of labor;
D O I
10.1080/00016340701409858
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background. The aim of this study was to compare the performance of the Bishop score and transvaginal ultrasonography to predict successful labor induction, and to estimate the most useful cut-off points for the two methods. Methods. The five components of the Bishop score were assessed by digital examination and cervical length was measured by transvaginal ultrasonography in 177 women with a single pregnancy, 36-42 weeks of gestation, and a live fetus in cephalic presentation before induction of labor. Results. Multiple regression analysis showed that the Bishop score, cervical length, and parity provided independent contribution in the prediction of the likelihood of delivering vaginally within 60 h. The only component of the Bishop score that was independently predictive of the probability of vaginal delivery within 60 h was station. The best cut-off points for predicting successful induction using receiver operating characteristic curves were 24 mm for cervical length and 4 for the Bishop score. Cervical length was a better predictor than the Bishop score (sensitivity and specificity of 66 and 77% versus 77 and 56%, respectively). Kaplan-Meier survival curves showed that cervical length was the best discriminator of successful induction. Conclusion. Measurement of cervical length by transvaginal ultrasonography is a better predictor of success in labor induction with both topical prostaglandin and oxytocin.
引用
收藏
页码:799 / 804
页数:6
相关论文
共 50 条
  • [31] Comparison of digital and ultrasonographic examination of the cervix in predicting time interval from induction to delivery in women with a low Bishop score
    Rozenberg, P
    Chevret, S
    Chastang, C
    Ville, Y
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (02) : 192 - 196
  • [32] Utility of intrapartum ultrasound in addition to Bishop score in predicting successful induction of labour
    Song, K.
    Kyung, K.
    Rae, B.
    Kim, H.
    Cho, G.
    Ahn, K.
    Oh, M.
    Kim, H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 264 - 264
  • [33] Ultrasonographic cervical length versus Bishop score for preinduction cervical assessment in parous women: a randomized clinical trial
    Ryu, Aeli
    Park, Kyo Hoon
    Lee, Sung Youn
    Jeong, Eun Ha
    Oh, Kyung Joon
    Kim, Ahra
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2013, 208 (01) : S134 - S134
  • [34] The Accuracy of Transvaginal Ultrasound and Bishop Score to Predict the Successful Induction of Labor in Primigravid as at Term
    Wajid, Rabia
    Hafeez, Sana
    Batool, Aasia
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2018, 24 (02): : 762 - 767
  • [35] Bishop score and the outcome of labor induction with misoprostol
    Szczesny, Witold
    Kjollesdal, Moyfrid
    Karlsson, Bengt
    Nielsen, Sven
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2006, 85 (05) : 579 - 582
  • [36] Changes in cervical nitric oxide concentration correlate with bishop score and cervical length modifications in prostaglandin E2-mediated induction of labor
    Chiossi, G
    Verocchi, G
    Venturini, P
    Facchinetti, F
    JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION, 2006, 13 (03) : 203 - 208
  • [37] Changes in Cervical Nitric Oxide Concentration Correlate With Bishop Score and Cervical Length Modifications in Prostaglandin E2-Mediated Induction of Labor
    Giuseppe Chiossi
    Gianluca Verocchi
    Paolo Venturini
    Fabio Facchinetti
    The Journal of the Society for Gynecologic Investigation: JSGI, 2006, 13 : 203 - 208
  • [38] Comparing Pre-Induction Ultrasound Parameters and the Bishop Score to Determine Whether Labor Induction Is Successful
    Milatovic, Stevan
    Krsman, Anita
    Baturan, Branislava
    Dragutinovic, Dorde
    Ilic, Dorde
    Stajic, Dragan
    MEDICINA-LITHUANIA, 2024, 60 (07):
  • [39] Transvaginal sonographic measurement of cervical length vs. Bishop score in labor induction at term: tolerability and prediction of Cesarean delivery
    Tan, P. C.
    Vallikkannu, N.
    Suguna, S.
    Quek, K. F.
    Hassan, J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (05) : 568 - 573
  • [40] Ultrasonographic measurement of cervical length in predicting mode of delivery after oxytocin induction
    Ali Yanik
    Çagri Gülümser
    Miraç Tosun