Accuracy of exercise testing in the assessment of the severity of myocardial ischemia as determined by means of technetium-99m tetrofosmin SPECT scintigraphy

被引:14
|
作者
Galassi, AR
Azzarelli, S
Lupo, L
Mammana, C
Foti, R
Tamburino, C
Musumeci, S
Giuffrida, G
机构
[1] Ferrarotto Hosp, Inst Cardiol, Catania, Italy
[2] Univ Catania, Lecturership Med Stat, I-95124 Catania, Italy
[3] Univ Catania, Chair Nucl Med, I-95124 Catania, Italy
关键词
exercise testing; technetium-99m tetrofosmin single photon emission computed tomography myocardial scintigraphy; rate-pressure product; ST/heart rate index;
D O I
10.1067/mnc.2000.108731
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The separation of patients with suspected or known coronary artery disease into low- and high-risk subgroups by means of noninvasive testing is highly relevant in the selection of patients who require further diagnostic or therapeutic investigation. We evaluated whether exercise electrocardiographic variables during exercise testing might be a means of predicting the severity of myocardial ischemia as assessed,vith myocardial scintigraphy. Methods and Results. We retrospectively reviewed 816 consecutive patients (mean age, 57 +/- 10 Sears) who underwent exercise technetium-99m tetrofosmin single photon emission computed tomography (SPECT) for the assessment of suspected or known coronary artery disease, Eight independent significant predictors of the extent and severity of reversible perfusion defects (ischemic perfusion score), which when integrated in a diagnostic algorithm satisfactorily discriminated patients with no reversible perfusion defects (sensitivity, 75%; specificity, 80%) and patients with severe impaired myocardial perfusion (greater than or equal to 11 ischemic perfusion score; sensitivity, 77%; specificity, 82%), were identified by means of stepwise discriminant analysis. However, patients,vith mildly to moderately impaired myocardial perfusion (greater than or equal to1 but <11 ischemic perfusion score) were poorly discriminated (sensitivity, 50%; specificity, 78%), The set of variables that were significant (P <.0001) for prediction included sex, myocardial infarction, exercise angina, the maximal amount of ST segment depression, rate-pressure product threshold criteria, slope of ST segment depression, ST/heart rate index, and peak exercise heart rate. Conclusions. The results of the use of clinical and electrocardiographic exercise variables satisfactorily agrees with the results from scintigraphy only for patients with no reversible perfusion defects and with severely impaired myocardial perfusion. However, it fails as an approach with universal applicability.
引用
收藏
页码:575 / 583
页数:9
相关论文
共 50 条
  • [41] Usefulness of technetium-99m tetrofosmin SPECT to detect abnormal myocardial perfusion in systemic lupus erythematosus or systemic sclerosis patients
    H.-B. Hsu
    C.-H. Kao
    Clinical Rheumatology, 2003, 22 : 495 - 495
  • [42] CLINICAL-VALUE OF TECHNETIUM-99M STANNOUS PYROPHOSPHATE MYOCARDIAL SCINTIGRAPHY
    MASUMI, S
    KATO, T
    OSADA, H
    HARUMI, K
    KOGA, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (08): : 913 - 914
  • [43] Usefulness of technetium-99m tetrofosmin SPECT to detect abnormal myocardial perfusion in systemic lupus erythematosus or systemic sclerosis patients
    Hsu, HB
    Kao, CH
    CLINICAL RHEUMATOLOGY, 2003, 22 (06) : 495 - 495
  • [44] CLINICOPATHOLOGIC CORRELATES OF TECHNETIUM-99M STANNOUS PYROPHOSPHATE MYOCARDIAL SCINTIGRAPHY IN PATIENTS
    POLINER, LR
    BUJA, LM
    PARKEY, RW
    BONTE, FJ
    STOKELY, EM
    PLATT, MR
    WILLERSON, JT
    CIRCULATION, 1976, 54 (04) : 80 - 80
  • [45] Accuracy and feasibility of technetium-99m tetrofosmin myocardial perfusion imaging to detect of spontane recanalization in patients with acute anterior myocardial infarction
    Hamada, S
    Nakamura, S
    Nishiue, T
    Watanabe, J
    Hatada, I
    Kudo, Y
    Fukui, M
    Fujimoto, T
    Baden, M
    Sugiura, T
    Iwasaka, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 430A - 430A
  • [46] Assessment of technetium-99m technegas scintigraphy for ventilatory impairment in pulmonary emphysema: Comparison of planar and SPECT images
    Satoh K.
    Tanabe M.
    Takahashi K.
    Kobayashi T.
    Nishiyama Y.
    Yamamoto Y.
    Honjo N.
    Sasaki M.
    Ohkawa M.
    Fujita J.
    Okada H.
    Annals of Nuclear Medicine, 1997, 11 (2) : 109 - 113
  • [47] Comparison of technetium-99m tetrofosmin and gallium-67 citrate scintigraphy for detecting malignant lymphoma
    Yang, CC
    Sun, SS
    Lin, CC
    Kao, CH
    Lee, CC
    ANTICANCER RESEARCH, 2001, 21 (05) : 3695 - 3698
  • [48] EVALUATION OF MYOCARDIAL UPTAKE OF TECHNETIUM-99M PYROPHOSPHATE IN CLINICAL EXERCISE-INDUCED VENTRICULAR ISCHEMIA
    BERMAN, DS
    SALEL, AF
    AMSTERDAM, EA
    DENARDO, GL
    MASON, DT
    CHEST, 1977, 71 (03) : 349 - 353
  • [49] Prognostic value of myocardial ischemia detected by Technetium-99m Myoview SPECT after coronary stent implantation
    Bokeria, L
    Aslanidis, I
    Alekiyn, B
    Mukhortova, O
    Vachromeeva, M
    Shurupova, I
    Klueva, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S307 - S307
  • [50] TECHNETIUM-99M PYROPHOSPHATE MYOCARDIAL SCINTIGRAPHY - RELIABILITY AND LIMITATIONS IN ACUTE MYOCARDIAL-INFARCTION
    COWLEY, MJ
    LOGIC, JR
    MANTLE, JA
    ROGERS, WJ
    RUSSELL, RO
    RACKLEY, CE
    CLINICAL RESEARCH, 1977, 25 (01): : A3 - A3