Two Low-Cost Solutions for Cardiac Mobile Monitoring

被引:0
|
作者
Gonzalez, R. I. [1 ]
Guardarrama, R. [1 ]
Leon, F. [1 ]
Rodriguez, A. [1 ]
Jimenez, D. [1 ]
机构
[1] Cent Inst Digital Res, IFMBE, Div Cardiol, Havana, Cuba
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5 | 2009年 / 25卷
关键词
Telemedicine; ECG monitoring; QRS detection;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A small device, named WalkECG, developed for out-of-hospital cardiac monitoring, is presented. Two models were developed, one including an embedded GSM/GPRS modem and a second model which is able to set a Bluetooth connection with a mobile phone. The device is based on the MSP430F1611 microcontroller and includes a two-channel ECG amplifier, a graphic LCD, a keypad, a GSM/GPRS embedded modem (or a Bluetooth module depending the model) and a battery. The heart rate, the ST segment deviation and the premature ventricular beats rate are computed; a normality limit is set for each one. When one of these limits is reached, an ECG strip is transmitted to a Telemedicine Central Station (TCS) and the device waits to display the receiving answer. The methods used to analyze the ECG were tested with twelve ECGs from MIT-BIH database. Never a ventricular beat was classified as normal and 98,05% of QRS complexes were detected. Also, the device was tested with volunteers and never an ECG strip was trnasmitted in a normal condition of the studied person. When the communication process was tested, a remarkable difference between the transmitting and receiving signals was not observed in a graphical comparison sample by sample.
引用
收藏
页码:188 / 191
页数:4
相关论文
共 50 条
  • [21] LOW-COST CONTROL AND MONITORING SYSTEM
    COLLA, G
    FORMIGGI.C
    ELECTRONIC ENGINEERING, 1973, 45 (546): : 13 - 13
  • [22] A Low-Cost Platform for Voice Monitoring
    Carullo, A.
    Vallan, A.
    Astolfi, A.
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 67 - 72
  • [23] Low-cost solutions for Martian base
    Kozicka, J.
    ADVANCES IN SPACE RESEARCH, 2008, 41 (01) : 129 - 137
  • [24] Low-cost solutions for trihalomethane compliance
    Banks, J.
    Wilson, D.
    Journal of the Chartered Institution of Water and Environmental Management, 2002, 16 (04): : 264 - 269
  • [25] Low-cost solutions for trihalomethane compliance
    Banks, J
    Wilson, D
    JOURNAL OF THE CHARTERED INSTITUTION OF WATER AND ENVIRONMENTAL MANAGEMENT, 2002, 16 (04): : 264 - 269
  • [26] A low-cost mobile platform for whole blood glucose monitoring using colorimetric method
    Zhang, Han
    Chen, Zheyuan
    Dai, Jing
    Zhang, Wei
    Jiang, Yuqian
    Zhou, Anhong
    MICROCHEMICAL JOURNAL, 2021, 162
  • [27] Low-cost solutions for mobile passive radar based on multichannel DPCA and NULA configurations
    Quirini, Andrea
    Blasone, Giovanni Paolo
    Colone, Fabiola
    Lombardo, Pierfrancesco
    INTERNATIONAL JOURNAL OF MICROWAVE AND WIRELESS TECHNOLOGIES, 2024, 16 (05) : 796 - 811
  • [28] LOW-COST FACIAL EXPRESSION ON MOBILE PLATFORM
    Chu, Chang-Chun
    Chen, Duan-Yu
    Hsieh, Jun-Wei
    PROCEEDINGS OF 2015 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOL. 2, 2015, : 586 - 590
  • [29] Mobile compounder offers low-cost installation
    Modern Plastics, 1998, 75 (07):
  • [30] A LOW-COST APPROACH TO CELLULAR MOBILE TELEPHONES
    HART, PJ
    HALL, TGR
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1991, 37 (01) : 32 - 38