A prospective study of symptoms during dobutamine stress echocardiography - Implications on diagnostic accuracy

被引:0
|
作者
Wagner, S [1 ]
MohrKahaly, S [1 ]
Nixdorff, U [1 ]
Kolsch, B [1 ]
Menzel, T [1 ]
Wittlich, N [1 ]
Meinert, R [1 ]
Meyer, J [1 ]
机构
[1] UNIV MAINZ,INST MED STAT,D-55101 MAINZ,GERMANY
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 1996年 / 85卷 / 08期
关键词
dobutamine stress; echocardiography; ischemia; chest pain; symptoms during dobutamine stress echocardiography;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We used a standardized questionnaire to assess physical and mental distress caused by dobutamine stress echocardiography (DSE). The examination was performed according to a standardized protocol (5-40 mu g/kg/min including atropine). 91 patients (pts), 68 men (62 +/- 9 years), 23 women (65 +/- 7 years) were asked to quantify the severity of the following symptoms: palpitations, anxiety, headache, nausea, discomfort of left lateral position, angina pectoris and dyspnea. Numbers on a rating scale from 1-10 defined the degree of distress. Absence of a symptom equalled mark 1, slight expression marks 2-4. Moderate expression was defined by marks 5-7 and very strong expression by marks 8-10. Results: 86% of pts felt affected by one or more symptoms to a slight to moderate extent (mark 4 +/- 2.17). Palpitations were felt by 85% of the pts (mark 6 +/- 2.83), anxiety by 42% (mark 3 +/- 2.5), headache by 50% (3 +/- 2.54), nausea by 20% (2 +/- 1.72), angina pectoris by 42% (3 +/- 2.5), dyspnea by 30% (2 +/- 2.42) and discomfort of left lateral recumbant position by 43% (mark 3 +/- 2.59). 43 pts underwent coronary angiography. The negative predictive value of DSE to identify pts without a coronary artery stenosis extending a 50% diameter reduction was 85% for the 16 pts who reached their individual submaximal heart rate compared to 60% for those 27 pts who did not reach it. Unspecific symptoms led to test termination in these pts. The positive predictive values were comparable (89 and 94%). Conclusion: DSE causes physical and mental distress. If symptoms lead to test termination before age corrected submaximal heart rate is reached, normal wall motion does not exclude significant coronary artery disease.
引用
收藏
页码:588 / 595
页数:8
相关论文
共 50 条
  • [21] Sustained ventricular tachycardia induced by dobutamine stress echocardiography: A prospective study
    Katritsis, DG
    Karabinos, I
    Papadopoulos, A
    Simeonidis, P
    Korovesis, S
    Giazitzoglou, E
    Karvouni, E
    Voridis, E
    EUROPACE, 2005, 7 (05): : 433 - 439
  • [22] Dobutamine stress echocardiography during follow-up surveillance in heart transplant patients: Diagnostic accuracy and predictors of outcomes
    Chirakarnjanakorn, Srisakul
    Starling, Randall C.
    Popovic, Zoran B.
    Griffin, Brian P.
    Desai, Milind Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (05): : 710 - 717
  • [23] Transesophageal dobutamine-atropine stress echocardiography: Diagnostic accuracy for corollary stenosis detection and localization
    Shahi, M
    Radhakrishnan, S
    Sinha, N
    Shrivastava, S
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 56 (02) : 185 - 192
  • [24] Methodological analysis of diagnostic dobutamine stress echocardiography studies
    Krenning, BJ
    Geleijnse, ML
    Poldermans, D
    Roelandt, JRTC
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2004, 21 (08): : 725 - 736
  • [25] Improvement in diagnostic accuracy of dobutamine-atropine stress echocardiography with infusion of beta-blocker at peak stress
    Tsutsui, J
    Mathias, W
    Kowatsch, I
    Henrique, EC
    Martinez, E
    Lemos, PA
    Leal, SB
    Andrade, JL
    EUROPEAN HEART JOURNAL, 2001, 22 : 117 - 117
  • [26] Lower limb pneumatic compression during dobutamine stress echocardiography in patients with normal resting wall motion: will it increase diagnostic accuracy?
    Abdel-Salam, Zainab
    Allam, Lawra
    Wadie, Bassem
    Enany, Bassem
    Nammas, Wail
    KARDIOLOGIA POLSKA, 2015, 73 (08) : 620 - 626
  • [27] SAFETY AND TOLERABILITY OF DOBUTAMINE-ATROPINE STRESS ECHOCARDIOGRAPHY - A PROSPECTIVE, MULTICENTER STUDY
    PICANO, E
    MATHIAS, W
    PINGITORE, A
    BIGI, R
    PREVITALI, M
    LANCET, 1994, 344 (8931): : 1190 - 1192
  • [28] Platelet activation during dobutamine stress echocardiography
    Galloway, MT
    Paglieroni, TG
    Wun, T
    Arena, FJ
    Lewis, WR
    AMERICAN HEART JOURNAL, 1998, 135 (05) : 888 - 900
  • [29] Hypertensive response during dobutamine stress echocardiography
    Lee, CY
    Pellikka, PA
    Shub, C
    Sinak, LJ
    Seward, JB
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (07): : 970 - &
  • [30] Is 3D Dobutamine stress echocardiography ready for prime time? Diagnostic and prognostic implications
    Shivalkar, Bharati
    De Keersmaeker, Alexander
    Van Hoeck, Nathan
    Belkova, Petra
    Van de Heyning, Caroline M.
    De Maeyer, Catherine
    Vrints, Christiaan
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (04) : 428 - 436