HIGH EFFICACY AND SAFETY RATE OF USING A 22-GAUGE EUS-FNA NEEDLE FOR EUS-GUIDED LIQUID BIOPSY FROM PORTAL VEIN FOR CIRCULATING TUMOR CELLS

被引:0
|
作者
Kongkam, Pradermchai
Prasoppokakorn, Thaninee
Luangsukrerk, Thanawat
Oung, Borathchakra
Tawainak, Pobsook
Chaiteerakij, Roongruedee
机构
关键词
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
3694460
引用
收藏
页码:AB522 / AB522
页数:1
相关论文
共 49 条
  • [41] A Prospective Comparison Study of a Standard 25-Gauge Needle With a 22-Gauge Core Needle Using Standard Suction and Capillary Suction Technique for Cytologic and Histologic EUS-Guided Sampling of Solid Pancreatic Lesions
    Weston, Brian R.
    Ross, William A.
    Bhutani, Manoop S.
    Lee, Jeffrey
    Pande, Mala
    Sholl, Andrew B.
    Krishnamurthy, Savitri
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : AB542 - AB543
  • [42] Systematic Review and Meta-Analysis of Diagnostic Accuracy of Endoscopic Ultrasound (EUS)-Guided Fine-Needle Aspiration (FNA) Using 22-gauge and 25-gauge Needles for Pancreatic Masses
    Tian, Guo
    Bao, Haiwei
    Li, Ju
    Jiang, Tian'an
    MEDICAL SCIENCE MONITOR, 2018, 24 : 8333 - 8341
  • [43] EVALUATION OF THE NEW 22-GAUGE EUS GUIDED BIOPSY NEEDLE (ACQUIRE) COMPARING TO ANOTHER NEW 20-GAUGE FNA NEEDLE WITH FORWARD-CUTTING BEVEL (PROCORE) IN PATIENTS WITH AUTOIMMUNE PANCREATITIS: A MULTICENTER RANDOMIZED TRIAL IN WEST JAPAN
    Kurita, Akira
    Zen, Yoh
    Yasukawa, Satoru
    Yoshimura, Ken-ichi
    Ogura, Takeshi
    Ozawa, Eisuke
    Okabe, Yoshinobu
    Asada, Masanori
    Nebiki, Hiroko
    Shigekawa, Minoru
    Ikeura, Tsukasa
    Eguchi, Takaaki
    Maruyama, Hirotsugu
    Ueki, Toshiharu
    Itonaga, Masahiro
    Hashimoto, Shinichi
    Shiomi, Hideyuki
    Minami, Ryuki
    Hoki, Noriyuki
    Takenaka, Mamoru
    Itokawa, Yoshio
    Uza, Norimitsu
    Hashigo, Shunpei
    Yasuda, Hiroaki
    Takada, Ryoji
    Kamada, Hideki
    Kawamoto, Hirofumi
    Kawakami, Hiroshi
    Moriyama, Ichiro
    Fujita, Koichi
    Hanada, Keiji
    Matsumoto, Hisakazu
    Yazumi, Shujiro
    GASTROINTESTINAL ENDOSCOPY, 2019, 89 (06) : AB612 - AB612
  • [44] MACROSCOPIC ON-SITE QUALITY EVALUATION OF BIOPSY SPECIMENS TO IMPROVE THE DIAGNOSTIC ACCURACY DURING EUS-GUIDED FNA USING A 19-GAUGE NEEDLE FOR SOLID LESIONS: A PROSPECTIVE RANDOMIZED CONTROLLED STUDY
    Chong, Charing
    Lakhtakia, Sundeep
    Hara, Kazuo
    Chan, Wah-Kheong
    Puri, Rajesh
    Almadi, Majid A.
    Nguyen, Nam
    Ang, Tiing Leong
    Kwek, Andrew
    Yasuda, Ichiro
    Doi, Shinpei
    Kida, Mitsuhiro
    Chan, Anthony W. H.
    Chan, Shannon M.
    Tang, Raymond S.
    Iwashita, Takuji
    Teoh, Anthony Y.
    GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : AB319 - AB319
  • [45] Diagnostic efficacy of white core cutoff lengths obtained by EUS-guided fine-needle biopsy using a novel 22G franseen biopsy needle and sample isolation processing by stereomicroscopy for subepithelial lesions
    Okuwaki, Kosuke
    Masutani, Hironori
    Kida, Mitsuhiro
    Yamauchi, Hiroshi
    Iwai, Tomohisa
    Miyata, Eiji
    Hasegawa, Rikiya
    Kaneko, Toru
    Imaizumi, Hiroshi
    Watanabe, Masafumi
    Kurosu, Takahiro
    Tadehara, Masayoshi
    Adachi, Kai
    Tamaki, Akihiro
    Koizumi, Wasaburo
    ENDOSCOPIC ULTRASOUND, 2020, 9 (03) : 187 - 192
  • [46] Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study)
    Iwashita, Takuji
    Yasuda, Ichiro
    Mukai, Tsuyoshi
    Doi, Shinpei
    Nakashima, Masanori
    Uemura, Shinya
    Mabuchi, Masatoshi
    Shimizu, Masahito
    Hatano, Yuichiro
    Hara, Akira
    Moriwaki, Hisataka
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (01) : 177 - 185
  • [47] ENDOSCOPIC ULTRASOUNG-GUIDED PORTAL VEIN SAMPLING OF CIRCULATING TUMOR CELLS IN PANCREATIC ADENOCARCINOMA - A PROSPECTIVE RANDOMIZED PILOT STUDY COMPARING A 22 AND 19-GAUGE (G) NEEDLE
    Weston, Brian R.
    Coronel, Emmanuel
    Lee, Jeffrey
    Guerrero, Paola A.
    Hurd, Mark W.
    Maitra, Anirban
    Bhutani, Manoop S.
    GASTROINTESTINAL ENDOSCOPY, 2021, 93 (06) : AB230 - AB230
  • [48] Cercariform Cells: Another Cytologic Feature Distinguishing Solid Pseudopaillary Tumor (SPPT) from Pancreatic Endocrine Neoplasms (PEN) and Acinar Cell Carcinomas (ACC) in Endoscopic Ultrasound-Guided Fine Needle Aspirates (EUS-FNA)
    Samad, A.
    Shah, A. A.
    Stelow, E. B.
    Cameron, S. E.
    Pambuccian, S. E.
    LABORATORY INVESTIGATION, 2012, 92 : 105A - 105A
  • [49] Cercariform Cells: Another Cytologic Feature Distinguishing Solid Pseudopaillary Tumor (SPPT) from Pancreatic Endocrine Neoplasms (PEN) and Acinar Cell Carcinomas (ACC) in Endoscopic Ultrasound-Guided Fine Needle Aspirates (EUS-FNA)
    Samad, A.
    Shah, A. A.
    Stelow, E. B.
    Cameron, S. E.
    Pambuccian, S. E.
    MODERN PATHOLOGY, 2012, 25 : 105A - 105A