Evaluation of endometrial receptivity during in-vitro fertilization using three-dimensional power Doppler ultrasound

被引:80
|
作者
Järvelä, IY [1 ]
Sladkevicius, P
Kelly, S
Ojha, K
Campbell, S
Nargund, G
机构
[1] Oulu Univ Hosp, Dept Obstet & Gynaecol, Oulu, Finland
[2] St George Hosp, Sch Med, Diana Princess Wales Ctr Reprod Med, Acad Dept Obstet & Gynaecol, London, England
[3] Univ Sjukhuset MAS, Dept Obstet & Gynecol, Kvinnoklin, Malmo, Sweden
[4] Fertil Associates, Auckland, New Zealand
[5] Ctr Reprod & Adv Technol, London, England
关键词
subendometrial flow; triple line; vascularization index;
D O I
10.1002/uog.2628
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To compare sonographic endometrial characteristics in in-vitro fertilization (IVF) cycles between women who conceive and those who do not. Methods Thirty-five women undergoing IVF treatment participated in the study. Using three-dimensional (3D) power Doppler ultrasound, we assessed endometrial patterns, volume and vascularization, after follicle stimulating hormone (FSH) stimulation but before human chorionic gonadotropin (bCG) administration (referred to hereafter as 'after FSH stimulation) and again on the day of oocyte retrieval. Results The pregnancy rate was 37% (13/35). After FSH stimulation, 29 of the 35 women bad a triple-line endometrial pattern, compared with five out of 35 on the day of oocyte retrieval. in those who bad a triple-line pattern after FSH stimulation the pregnancy rate was 44.8% (13/29) and it was 0% (016) in those with a homogeneous pattern (chi-square test, P = 0.039). If a triple-line pattern was present on the day of oocyte retrieval the pregnancy rate was 80.0% (415), whereas if the pattern was homogeneous the pregnancy rate was 30.0% (9/30) (P = 0.032). There were no differences between those who conceived and those who did not in endometrial thickness, volume or vascularization on either day examined. Endometrial volume decreased significantly after bCG injection in women who conceived, but not in those who did not conceive. In both groups endometrial and subendometrial vascularization decreased after bCG injection, while the endometrial thickness remained unchanged. Conclusions The existence of a homogeneous endometrial pattern after FSH stimulation seems to be a prognostic sign of an adverse outcome in IVF, while a triple-line pattern after FSH stimulation and a decrease in endometrial volume appear to be associated with conception. Copyright (c) 2005 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:765 / 769
页数:5
相关论文
共 50 条
  • [21] Cumulus assessment by three-dimensional ultrasound for in vitro fertilization
    Poehl, M
    Hohlagschwandtner, M
    Doerner, V
    Dillinger, B
    Feichtinger, W
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (03) : 251 - 253
  • [22] The role of endometrial and subendometrial blood flows by three-dimensional power Doppler ultrasound in the prediction of pregnancy during IVF
    Ng, E. H. Y.
    Chan, C. C. W.
    Tang, O. S.
    Yeung, W. S. B.
    Ho, P. C.
    HUMAN REPRODUCTION, 2006, 21 : I7 - I7
  • [23] THE VALUE OF THREE-DIMENSIONAL ULTRASOUND IN PREDICTION OF POOR OVARIAN RESPONSE IN IN-VITRO FERTILIZATION CYCLES
    Wong, W. Y.
    Haines, C.
    FERTILITY AND STERILITY, 2012, 98 (03) : S223 - S223
  • [24] Three-dimensional ultrasound and three-dimensional power Doppler in the assessment of ovarian tumors
    Laban, M.
    Metawee, H.
    Elyan, A.
    Kamal, M.
    Kamel, M.
    Mansour, G.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 99 (03) : 201 - 205
  • [25] Assessment of endometrial volume by three-dimensional ultrasound prior to embryo transfer:: clues to endometrial receptivity
    Raga, F
    Bonilla-Musoles, F
    Casañ, EM
    Klein, O
    Bonilla, F
    HUMAN REPRODUCTION, 1999, 14 (11) : 2851 - 2854
  • [26] Three-dimensional ultrasound and three-dimensional power Doppler improve the preoperative evaluation of complex benign ovarian lesions
    Vrachnis, N.
    Sifakis, S.
    Samoli, E.
    Kappou, D.
    Pavlakis, K.
    Iliodromiti, Z.
    Botsis, D.
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2012, 39 (04): : 474 - 478
  • [27] Diagnostic value of three-dimensional power Doppler ultrasound for postmenopausal bleeding compared with endometrial thickness
    Kim, Heung Yeol
    Kim, Ari
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2016, 55 (02): : 305 - 305
  • [28] Factors affecting endometrial and subendometrial blood flow measured by three-dimensional power Doppler ultrasound during IVF treatment
    Ng, EHY
    Chan, CCW
    Tang, OS
    Yeung, WSB
    Ho, PC
    HUMAN REPRODUCTION, 2006, 21 (04) : 1062 - 1069
  • [29] Is three-dimensional power Doppler ultrasound better than two-dimensional power Doppler?
    Guerriero, S
    Ajossa, S
    Melis, G
    GYNECOLOGIC ONCOLOGY, 2002, 84 (02) : 352 - 353
  • [30] Evaluation of the effect of machine settings on quantitative three-dimensional power Doppler angiography:: an in-vitro flow phantom experiment
    Raine-Fenning, N. J.
    Nordin, N. M.
    Ramnarine, K. V.
    Campbell, B. K.
    Clewes, J. S.
    Perkins, A.
    Johnson, I. R.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (04) : 551 - 559