Measurement of light output response in scintillator based neutron detectors using quasi-monoenergetic neutrons

被引:7
|
作者
Roy, A. S. [1 ,2 ]
Banerjee, K. [2 ,3 ]
Roy, P. [2 ,3 ]
Seth, S. [4 ]
Rana, T. K. [2 ,3 ]
Sen, A. [2 ,3 ]
Pandit, D. [3 ]
Kundu, S. [2 ,3 ]
Ghosh, T. K. [2 ,3 ]
Mukherjee, G. [2 ,3 ]
Manna, S. [2 ,3 ]
Pandey, R. [3 ]
Paul, D. [2 ,3 ]
Atreya, K. [2 ,3 ]
Basu, S. [2 ,3 ]
Suman, V [1 ]
Rout, P. C. [2 ,5 ]
Santhosh, T. [2 ,5 ]
Mukhopadhyay, S. [2 ,3 ]
Mondal, D. [3 ]
Pal, S. [3 ,7 ]
Saha, S. [6 ]
Das, M. [6 ]
Ravishankar, R. [1 ]
Kulkarni, M. S. [1 ,2 ]
Bhattacharya, C. [2 ,3 ]
机构
[1] Bhabha Atom Res Ctr, Hlth Phys Div, Mumbai 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Training Sch Complex, Mumbai 400094, Maharashtra, India
[3] Variable Energy Cyclotron Ctr, 1-AF Bidhannagar, Kolkata 700064, India
[4] Bose Inst, EN-80,Sect 5, Kolkata 700091, India
[5] Bhabha Atom Res Ctr, Nucl Phys Div, Mumbai 400085, Maharashtra, India
[6] Saha Inst Nucl Phys, 1-AF Bidhan Nagar, Kolkata 700064, India
[7] Tata Inst Fundamental Res, Mumbai 400005, Maharashtra, India
关键词
Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); Neutron detectors (cold; thermal; fast neutrons); Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators); PULSE-SHAPE-DISCRIMINATION; EJ-299-33A PLASTIC SCINTILLATOR; EJ; 299-33; GAMMA DISCRIMINATION; SPECTROMETRY; SIMULATION; CYCLOTRON; GEANT4; BEAM;
D O I
10.1088/1748-0221/16/07/P07045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Conventional liquid scintillator (BC501A) and pulse shape discrimination capable plastic scintillator (EJ-299-33A) based detector of dimension; 5 inch diameter and 5 inch long, have been used to study pulse height response for quasi-monoenergetic neutrons of energy in the range 3 to 15 MeV generated using Li-7(p,n)Be-7 reaction. Scintillation light output of plastic scintillator having pulse shape discrimination property is found to be 75% of the liquid scintillator at neutron energy (maximum recoil proton energy) of 3 MeV which improves with the increase in energy. Functional dependence of the scintillation light output in terms of recoil protons energy has been determined for the liquid and the plastic scintillator detectors for neutron energy in the range 3 to 15 MeV. This functional dependences were used in the Geant4 simulation to calculate the pulse height responses at several neutron energies.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Measurement of cross sections for flux monitor reactions using quasi-monoenergetic neutrons
    Vashi, Vibhuti
    Makwana, Rajnikant
    Mukherjee, S.
    Soni, B. K.
    Mehta, M. H.
    Parashari, S.
    Singh, R. K.
    Chauhan, R.
    Suryanarayana, S., V
    Nayak, B. K.
    Sharma, S. C.
    Naik, H.
    Singh, N. L.
    Nag, T. N.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (07):
  • [2] Measurement of cross sections for flux monitor reactions using quasi-monoenergetic neutrons
    Vibhuti Vashi
    Rajnikant Makwana
    S. Mukherjee
    B. K. Soni
    M. H. Mehta
    S. Parashari
    R. K. Singh
    R. Chauhan
    S. V. Suryanarayana
    B. K. Nayak
    S. C. Sharma
    H. Naik
    N. L. Singh
    T. N. Nag
    The European Physical Journal Plus, 136
  • [3] Unfolding procedure for SER measurements using quasi-monoenergetic neutrons
    Olmos, M
    Prokofiev, A
    Gaillard, R
    2005 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM PROCEEDINGS - 43RD ANNUAL, 2005, : 696 - 697
  • [4] Measured response of a liquid scintillation detector to quasi-monoenergetic electrons and neutrons
    Rout, P. C.
    Gandhi, A.
    Basak, T.
    Thomas, R. G.
    Ghosh, C.
    Mitra, A.
    Mishra, G.
    Behera, S. P.
    Kujur, R.
    Mirgule, E. T.
    Nayak, B. K.
    Saxena, A.
    Kumar, S.
    Datar, V. M.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [5] Reaction d + 2H → 3He + n as a source of quasi-monoenergetic neutrons for studying the properties of neutron detectors
    Zuyev S.V.
    Kasparov A.A.
    Konobeevski E.S.
    Lebedev V.M.
    Mordovskoy M.V.
    Spassky A.V.
    Bulletin of the Russian Academy of Sciences: Physics, 2016, 80 (3) : 232 - 236
  • [6] EVALUATION OF A PERSONAL AND ENVIRONMENTAL DOSEMETER BASED ON CR-39 TRACK DETECTORS IN QUASI-MONOENERGETIC NEUTRON FIELDS
    Caresana, M.
    Ferrarini, M.
    Parravicini, A.
    Naik, A. Sashala
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 100 - 103
  • [7] A 30 MeV-cyclotron-based quasi-monoenergetic neutron source
    Chu, Kuo-Yuan
    Kuo, Weng-Sheng
    Lee, How-Ming
    Fuh, Yiin-Kuen
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (05) : 1559 - 1566
  • [8] Response of a PIN Diode and SOI Microdosimeter to the TSL Quasi-Monoenergetic Neutron Field
    Prokopovich, Dale Anthony
    Reinhard, M. I.
    Cornelius, Iwan M.
    Rosenfeld, Anatoly B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (06) : 3321 - 3327
  • [9] Development and Evaluation of Activation Neutron Detectors for Spectrum Measurements of Quasi-Monoenergetic High-Energy Neutron Fields
    Masuda, A.
    Matsumoto, T.
    Harano, H.
    Yoshitomi, H.
    Tanimura, Y.
    Shikaze, Y.
    Kurashima, S.
    Seito, H.
    Hagiwara, M.
    Unno, Y.
    Nishiyama, J.
    Yoshizawa, M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [10] Measurement of the Response Function of a Custom Plastic Scintillator Using Monoenergetic Neutron and Proton Sources
    Kanj, Aya
    Lynde, Clement
    Carrel, Frederick
    Mosbah, Mehdi Ben
    Venara, Julien
    El Bitar, Ziad
    Rousseau, Marc
    Babut, Richard
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (09) : 2133 - 2139