EVALUATION OF A PERSONAL AND ENVIRONMENTAL DOSEMETER BASED ON CR-39 TRACK DETECTORS IN QUASI-MONOENERGETIC NEUTRON FIELDS

被引:9
|
作者
Caresana, M. [1 ]
Ferrarini, M. [2 ]
Parravicini, A. [3 ]
Naik, A. Sashala [1 ,3 ]
机构
[1] Politecn Milan, CESNEF, Dipartimento Energia, I-20133 Milan, Italy
[2] Fdn CNAO, I-27100 Pavia, Italy
[3] Mi Srl, I-29029 Fabiano Di Rivergaro, PC, Italy
关键词
D O I
10.1093/rpd/nct320
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, the evaluation of the dosimetric capability of a detector based on a CR-39 solid-state nuclear track detector coupled to a 1 cm thickness of PMMA radiator was made with the aim of understanding the applicability of this technique to personal and environmental neutron dosimetry. The dosemeter has been exposed to monoenergetic and quasi-monoenergetic neutron beams at PTB in Braunschweig, Germany and at Ithemba Laboratories, in Faure, South Africa, with peak energies ranging from 0.565 to 100MeV. The results showed a response that is almost independent of the neutron energy in the whole energy range.
引用
收藏
页码:100 / 103
页数:4
相关论文
共 50 条
  • [1] Further investigations on CR-39 fast neutron personal dosemeter
    Djeffal, S
    Lounis, Z
    Allab, M
    Izerrouken, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 398 (2-3): : 343 - 350
  • [2] Further investigations on CR-39 fast neutron personal dosemeter
    Djeffal, S.
    Lounis, Z.
    Allab, M.
    Izerrouken, M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 398 (2-3): : 343 - 350
  • [3] Progress towards the development of a CR-39 fast neutron personal dosemeter
    Djeffal, S.
    Lounis, Z.
    Nuclear Tracks and Radiation Measurements, 1991, 19 (1-4): : 457 - 460
  • [4] Neutron spectrometry using CR-39 track etch detectors
    Phillips, Gary W.
    Spann, Jerrette E.
    Bogard, James S.
    VoDinh, Tuan
    Emfietzoglou, Dimitris
    Devine, Robert T.
    Moscovitch, Marko
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 457 - 460
  • [5] Fast neutron spectroscopy using CR-39 track detectors
    El-Sersy, AR
    Eman, SA
    Khaled, NE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 226 (03): : 345 - 350
  • [6] Development and Evaluation of Activation Neutron Detectors for Spectrum Measurements of Quasi-Monoenergetic High-Energy Neutron Fields
    Masuda, A.
    Matsumoto, T.
    Harano, H.
    Yoshitomi, H.
    Tanimura, Y.
    Shikaze, Y.
    Kurashima, S.
    Seito, H.
    Hagiwara, M.
    Unno, Y.
    Nishiyama, J.
    Yoshizawa, M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [7] Measurement of track parameters and etch rates in proton-irradiated CR-39 detectors and simulation of neutron dosemeter responses
    Dorschel, B
    Fulle, D
    Hartmann, H
    Hermsdorf, D
    Kadner, K
    Radlach, C
    RADIATION PROTECTION DOSIMETRY, 1997, 69 (04) : 267 - 274
  • [8] The use of ultrasonic properties of CR-39 track detectors in neutron dosimetry
    Afifi, H
    El-Sersy, A
    Khaled, N
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2004, 159 (01): : 37 - 43
  • [9] Note: Fast neutron efficiency in CR-39 nuclear track detectors
    Cavallaro, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (03):
  • [10] FAST-NEUTRON SPECTROMETRY USING CR-39 TRACK DETECTORS
    DAJKO, G
    RADIATION PROTECTION DOSIMETRY, 1990, 34 (1-4) : 9 - 12