Fetal ECG Extraction From Maternal ECG Using Attention-Based CycleGAN

被引:45
|
作者
Mohebbian, Mohammad Reza [1 ]
Vedaei, Seyed Shahim [1 ]
Wahid, Khan A. [1 ]
Dinh, Anh [1 ]
Marateb, Hamid Reza [2 ,3 ]
Tavakolian, Kouhyar [4 ]
机构
[1] Univ Saskatchewan, Dept Elect & Comp Engn, Saskatoon, SK S7N 5A9, Canada
[2] Univ Isfahan, Biomed Engn Dept, Esfahan 8174673441, Iran
[3] Univ Politecn Cataluna, BarcelonaTech UPC, Dept Automat Control, Biomed Engn Res Ctr, Barcelona 08082, Spain
[4] Univ North Dakota, Biomed Engn Program, Grand Forks, ND 58202 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Fetal ECG; CycleGAN; blind source separation; attention layer; QRS COMPLEX DETECTION; HEART-RATE; ELECTROCARDIOGRAPHY; CARDIOLOGY; SIGNALS; MODEL;
D O I
10.1109/JBHI.2021.3111873
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A non-invasive fetal electrocardiogram (FECG) is used to monitor the electrical pulse of the fetal heart. Decomposing the FECG signal from the maternal ECG (MECG) is a blind source separation problem, which is hard due to the low amplitude of the FECG, the overlap of R waves, and the potential exposure to noise from different sources. Traditional decomposition techniques, such as adaptive filters, require tuning, alignment, or pre-configuration, such as modeling the noise or desired signal to map the MECG to the FECG. The high correlation between maternal and fetal ECG fragments decreases the performance of convolution layers. Therefore, the masking region of interest based on the attention mechanism was performed to improve the signal generators' precision. The sine activation function was also used to retain more details when converting two signal domains. Three available datasets from the Physionet, including the A&D FECG, NI-FECG, and NI-FECG challenge, and one synthetic dataset using FECGSYN toolbox, were used to evaluate the performance. The proposed method could map an abdominal MECG to a scalp FECG with an average of 98% R-Square [CI 95%: 97%, 99%] as the goodness of fit on the A&D FECG dataset. Moreover, it achieved 99.7% F1-score [CI 95%: 97.8-99.9], 99.6% F1-score [CI 95%: 98.2%, 99.9%] and 99.3% F1-score [CI 95%: 95.3%, 99.9%] for fetal QRS detection on the A&D FECG, NI-FECG and NI-FECG challenge datasets, respectively. Also, the distortion was in the "very good" and "good" ranges. These results are comparable to the state-of-the-art results; thus, the proposed algorithm has the potential to be used for high-performance signal-to-signal conversion.
引用
收藏
页码:515 / 526
页数:12
相关论文
共 50 条
  • [21] Fetal ECG Extraction using πTucker Decomposition
    Akbari, Hassan
    Shamsollahi, Mohammad B.
    Phlypo, Ronald
    2015 INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP 2015), 2015, : 174 - 178
  • [22] Maternal ECG removal from non-invasive fetal ECG recordings
    Vullings, Rik
    Peters, Chris
    Mischi, Massinio
    Oei, Guid
    Bergmans, Jan
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1059 - +
  • [23] Unobtrusive Acquisition and Extraction of Fetal and Maternal ECG in the Home Setting
    Sharma, Manuja
    Ritchie, Peter
    Ghirmai, Tadesse
    Cao, Hung
    Lau, Michael P. H.
    2017 IEEE SENSORS, 2017, : 936 - 938
  • [24] Virtual Instrumentation Based Fetal ECG Extraction
    Raj, Chinmayee G.
    Harsha, V. Sri
    Gowthami, B. Sai
    Sunitha, R.
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON ECO-FRIENDLY COMPUTING AND COMMUNICATION SYSTEMS, 2015, 70 : 289 - 295
  • [25] Extraction of Fetal ECG from Abdominal ECG and Heart Rate Variability Analysis
    Lamesgin, Gizeaddis
    Kassaw, Yonas
    Assefa, Dawit
    AFRO-EUROPEAN CONFERENCE FOR INDUSTRIAL ADVANCEMENT, AECIA 2014, 2015, 334 : 65 - 76
  • [26] EXTRACTION OF FETAL ECG FROM ABDOMINAL SIGNAL
    Prasad, D. V.
    Swarnalatha, R.
    BIOSIGNALS 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING, 2009, : 245 - 248
  • [27] An Efficient Method for Fetal ECG Extraction From Single Channel Abdominal ECG
    Panigrahy, D.
    Rakshit, M.
    Sahu, P. K.
    2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 1083 - 1088
  • [28] Fetal heart rate extraction from composite maternal ECG using complex continuous wavelet transform
    Karvounis, EC
    Papaloukas, C
    Fotiadis, DI
    Michalis, LK
    COMPUTERS IN CARDIOLOGY 2004, VOL 31, 2004, 31 : 737 - 740
  • [29] Synthetic database for testing algorithms of fetal ECG extraction from abdominal ECG
    Facultad Ingeniería de Telecomunicaciones, Universidad Santo Tomás, Bucaramanga, Colombia
    不详
    STSIVA - Symp. Image, Signal Process., Artif. Vis., (56-61):
  • [30] Attention-Based Residual Dense Shrinkage Network for ECG Denoising
    Zhang, Dengyong
    Yuan, Minzhi
    Li, Feng
    Zhang, Lebing
    Sun, Yanqiang
    Ling, Yiming
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2024, 138 (03): : 2809 - 2824