Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation

被引:38
|
作者
Ghosh, Justin [1 ,2 ,3 ]
Singarayar, Suresh [2 ,3 ]
Kabunga, Peter [2 ,3 ]
McGuire, Mark A. [1 ,2 ,3 ]
机构
[1] Mater Hosp, Sydney, NSW, Australia
[2] Royal Prince Alfred Hosp, Sydney, NSW, Australia
[3] Univ Sydney, Sydney, NSW 2006, Australia
来源
EUROPACE | 2015年 / 17卷 / 06期
关键词
Cryoballoon; Atrial fibrillation; Phrenic nerve palsy; INJURY; CATHETER; EFFICACY; SAFETY;
D O I
10.1093/europace/euu341
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Methods and results Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P< 0.001). Venous pressure waveforms were obtained in all patients and attenuation of the waveform was always observed prior to onset of phrenic nerve palsy. Conclusion The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage.
引用
收藏
页码:884 / 890
页数:7
相关论文
共 50 条
  • [41] Right ventricular rapid pacing in catheter ablation of atrial fibrillation: a novel application for cryoballoon pulmonary vein isolation
    Chun, K. R. Julian
    Fuernkranz, Alexander
    Schmidt, Boris
    Metzner, Andreas
    Tilz, Roland
    Zerm, Thomas
    Koester, Ilka
    Koektuerk, Buelent
    Konstantinidou, Melanie
    Ouyang, Feifan
    Kuck, Karl Heinz
    CLINICAL RESEARCH IN CARDIOLOGY, 2009, 98 (08) : 493 - 500
  • [42] Visualization and mapping of the right phrenic nerve by intracardiac echocardiography during atrial fibrillation ablation
    Liu, Xinmeng
    Lin, Rong
    Peng, Xiaodong
    Wang, Xuesi
    Li, Yukun
    Liu, Xiaoxia
    Wang, Wei
    Yu, Ronghui
    Bai, Rong
    Ma, Changsheng
    Ruan, Yanfei
    Liu, Nian
    EUROPACE, 2023, 25 (04): : 1352 - 1360
  • [43] Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation
    Aryana, Arash
    Mugnai, Giacomo
    Singh, Sheldon M.
    Pujara, Deep K.
    de Asmundis, Carlo
    Singh, Steve K.
    Bowers, Mark R.
    Brugada, Pedro
    d'Avila, Andre
    O'Neill, Padraig Gearoid
    Chierchia, Gian-Battista
    HEART RHYTHM, 2016, 13 (02) : 424 - 432
  • [44] Clinical experience with a diaphragmatic electromyographic-guided approach to monitor phrenic nerve integrity during cryoballoon-based atrial fibrillation ablation
    Mondesert, B.
    Andrade, J. G.
    Guerra, P. G.
    Rivard, L.
    Macle, L.
    Thibault, B.
    Talajic, M.
    Roy, D.
    Khairy, P.
    Dubuc, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 91 - 91
  • [45] Impact on Clinical Outcome of Premature Interruption of Cryoenergy Delivery Due to Phrenic Nerve Palsy During Second Generation Cryoballoon Ablation for Paroxysmal Atrial Fibrillation
    Chierchia, Gian-Battista
    Mugnai, Giacomo
    Hunuk, Burak
    Stroker, Erwin
    Velagic, Vedran
    Saitoh, Yukio
    Irfan, Ghazala
    Hacioglu, Ebru
    Ciconte, Giuseppe
    Brugada, Pedro
    De Asmundis, Carlo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (09) : 950 - 955
  • [46] Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
    Kosmidou, Ioanna
    Wooden, Shannnon
    Jones, Brian
    Deering, Thomas
    Wickliffe, Andrew
    Dan, Dan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (72):
  • [47] Clinical Experience With a Novel Electromyographic Approach to Preventing Phrenic Nerve Injury During Cryoballoon Ablation in Atrial Fibrillation (vol 7, pg 605, 2014)
    Shohoudi, Azadeh
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (05): : 995 - 995
  • [48] Procedural Parameters During Cryoballoon Ablation Predict Early Pulmonary Vein Reconnection and Atrial Fibrillation Recurrence
    Chahine, Yaacoub
    Afroze, Tanzina
    Bifulco, Savannah
    Macheret, Fima
    Abdulsalam, Nashwa
    Boyle, Patrick M.
    Akoum, Nazem W.
    CIRCULATION, 2022, 146
  • [49] Phrenic Nerve Injury Despite High-Output Pacing in Patients Undergoing Radiofrequency Catheter Ablation of Atrial Fibrillation
    Izzo, Brett
    Yokokawa, Miki
    Jongnarangsin, Krit
    Ghanbari, Hamid
    Latchamsetty, Rakesh
    Crawford, Thomas
    Good, Eric
    Bogun, Frank
    Pelosi, Frank
    Oral, Hakan
    Morady, Fred
    Chugh, Aman
    CIRCULATION, 2014, 130
  • [50] ECG-Guided Surveillance Technique in Cryoballoon Ablation for Paroxysmal and Persistent Atrial Fibrillation: A Strategy to Prevent From Phrenic Nerve Palsy
    Meissner, Axel
    Maagh, Petra
    Christoph, Arndt
    Oernek, Ahmet
    Plehn, Gunnar
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2016, 13 (06): : 403 - 411