Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation

被引:38
|
作者
Ghosh, Justin [1 ,2 ,3 ]
Singarayar, Suresh [2 ,3 ]
Kabunga, Peter [2 ,3 ]
McGuire, Mark A. [1 ,2 ,3 ]
机构
[1] Mater Hosp, Sydney, NSW, Australia
[2] Royal Prince Alfred Hosp, Sydney, NSW, Australia
[3] Univ Sydney, Sydney, NSW 2006, Australia
来源
EUROPACE | 2015年 / 17卷 / 06期
关键词
Cryoballoon; Atrial fibrillation; Phrenic nerve palsy; INJURY; CATHETER; EFFICACY; SAFETY;
D O I
10.1093/europace/euu341
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Methods and results Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P< 0.001). Venous pressure waveforms were obtained in all patients and attenuation of the waveform was always observed prior to onset of phrenic nerve palsy. Conclusion The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage.
引用
收藏
页码:884 / 890
页数:7
相关论文
共 50 条
  • [1] FEASIBILITY OF LEFT PHRENIC NERVE PACING DURING CRYOBALLOON ATRIAL FIBRILLATION ABLATION
    Dar, Tawseef
    Yarlagadda, Bharath
    Veerapaneni, Vaishnavi
    Atkins, Donita
    Sheldon, Seth
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 347 - 347
  • [2] Clinical feasibility of pulmonary vein orifice pacing for the prediction of phrenic nerve injury during cryoballoon ablation of atrial fibrillation
    Sano, Makoto
    Urushida, Tsuyoshi
    Matsukura, Gaku
    Sakakibara, Tomoaki
    Suwa, Kenichiro
    Naruse, Yoshihisa
    Ohtani, Hayato
    Saotome, Masao
    Maekawa, Yuichiro
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (08) : 1200 - 1206
  • [3] Methods for steadily right phrenic nerve pacing in patients with cryoballoon ablation for atrial fibrillation
    Liu, Zheng
    Zhang, Shu
    Fang, Pihua
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C185 - C185
  • [4] Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: The first human application
    Franceschi, Frederic
    Dubuc, Marc
    Guerra, Peter G.
    Khairy, Paul
    HEART RHYTHM, 2011, 8 (07) : 1068 - 1071
  • [5] INCIDENCE AND PREDICTORS OF COMPLICATIONS AND PHRENIC NERVE INJURY DURING CRYOBALLOON ABLATION FOR ATRIAL FIBRILLATION
    Guhl, Emily
    Siddoway, Donald
    Adelstein, Evan
    Voigt, Andrew
    Saba, Samir
    Jain, Sandeep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 759 - 759
  • [6] Femoral venous pressure waveform as indicator of phrenic nerve injury in the setting of second-generation cryoballoon ablation
    Mugnai, Giacomo
    de Asmundis, Carlo
    Stroker, Erwin
    Hunuk, Burak
    Moran, Darragh
    Ruggiero, Diego
    De Regibus, Valentina
    Coutino-Moreno, Hugo Enrique
    Takarada, Ken
    Choudhury, Rajin
    Poelaert, Jan
    Verborgh, Christian
    Brugada, Pedro
    Chierchia, Gian-Battista
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (07) : 510 - 517
  • [7] Recordings of diaphragmatic electromyograms during cryoballoon ablation for atrial fibrillation accurately predict phrenic nerve injury
    Lakhani, Mayur
    Saiful, Faisul
    Parikh, Valay
    Goyal, Nikhil
    Bekheit, Soad
    Kowalski, Marcin
    HEART RHYTHM, 2014, 11 (03) : 369 - 374
  • [8] Quick, safe, and effective maneuver to prevent phrenic nerve injury during cryoballoon ablation of atrial fibrillation
    Okishige, Kaoru
    Aoyagi, Hideshi
    Shigeta, Takatoshi
    Nakamura, Rena A.
    Nishimura, Takuro
    Yamauchi, Yasuteru
    Keida, Takehiko
    Sasano, Tetsuo
    Hirao, Kenzo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (02) : 233 - 238
  • [9] Quick, safe, and effective maneuver to prevent phrenic nerve injury during cryoballoon ablation of atrial fibrillation
    Kaoru Okishige
    Hideshi Aoyagi
    Takatoshi Shigeta
    Rena A. Nakamura
    Takuro Nishimura
    Yasuteru Yamauchi
    Takehiko Keida
    Tetsuo Sasano
    Kenzo Hirao
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 233 - 238
  • [10] Left Phrenic Nerve Pacing From the Left Subclavian Vein Novel Method to Monitor for Left Phrenic Nerve Injury During Catheter Ablation