Single and Double Reference Points Based High Precision 3D Indoor Positioning with Camera and Orientation-Sensor on Smart Phone

被引:1
|
作者
Li, Honggui [1 ]
机构
[1] Yangzhou Univ, Phys Coll Sci & Technol, Yangzhou 225000, Jiangsu, Peoples R China
关键词
3D indoor positioning; Orientation-sensor; P3P; Smart phone; POSE;
D O I
10.1007/s11277-015-2499-7
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
This paper proposes a high precision 3D indoor positioning method, which depends on one or two reference points in scene and camera and orientation-sensor on smart phone. The proposed method has the merits of implementing simplicity, high accuracy, friendly availability and low cost. The proposed method adopts only single or double reference points and camera imaging model for camera calibrating and 3D positioning. Classical camera calibration method uses a set of reference points, but the proposed camera calibration method is easier to implement. Traditional computer vision based positioning method, P3P, utilizes at least three points and has multiple solutions. The proposed positioning method is equal to P2P or P1P, but is faster and has unique solution. The proposed method achieves the high 3D positioning precision at the level less than 30 cm. The proposed method employs smart phone as hardware and software carrier, which is more usable than other methods. In a word, the proposed method is very suitable for low-cost and high precision 3D indoor positioning.
引用
收藏
页码:1995 / 2011
页数:17
相关论文
共 45 条
  • [41] High-turbidity underwater Fourier single-pixel 3D imaging based on pseudo-camera calibration with pixel-mapping at low sampling rates
    Feng, Wei
    Li, Shuyang
    Wang, Bincheng
    Zhai, Zhongsheng
    OPTICS AND LASERS IN ENGINEERING, 2025, 186
  • [42] T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1
    Chenxi Hu
    Albert J. Sinusas
    Steffen Huber
    Stephanie Thorn
    Mitchel R. Stacy
    Hamid Mojibian
    Dana C. Peters
    Journal of Cardiovascular Magnetic Resonance, 19
  • [43] T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1
    Hu, Chenxi
    Sinusas, Albert J.
    Huber, Steffen
    Thorn, Stephanie
    Stacy, Mitchel R.
    Mojibian, Hamid
    Peters, Dana C.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [44] A novel data-driven based high-precision building roof contour full-automatic extraction and structured 3D reconstruction method combining stereo images and LiDAR points
    Xiao, Xiongwu
    Wang, Kai
    Zhong, Zhichao
    Qu, Wenhu
    Wu, Weiwei
    Cui, Zhigao
    Su, Yanzhao
    Li, Aihua
    Gong, Jianya
    Li, Deren
    INTERNATIONAL JOURNAL OF DIGITAL EARTH, 2025, 18 (01)
  • [45] High-precision composite 3D shape measurement of aeroengine blade based on parallel single-pixel imaging and high-dynamic range N-step fringe projection profilometry
    Jiang, Hongzhi
    Wang, Qi
    Zhao, Huijie
    Li, Xudong
    OPTICS AND LASER TECHNOLOGY, 2024, 170