Comparative Evaluation of Two Bracket Systems' Bond Strength: Conventional and Self-Ligating

被引:3
|
作者
Vartolomei, Aurel-Claudiu [1 ]
Ghiga, Dana-Valentina [1 ]
Serbanoiu, Dan-Cosmin [1 ]
Moldovan, Marioara [2 ]
Cuc, Stanca [2 ]
Pacurar, Mariana [1 ]
Pollmann, Maria Cristina Figueiredo [3 ]
机构
[1] GEP Univ Med Pharm Sci & Technol Targu Mures, Fac Dent Med, Targu Mures 540139, Romania
[2] Babes Bolyai Univ, Raluca Ripan Chem Res Inst, Cluj Napoca 400294, Romania
[3] Univ Porto, Fac Dent Med, P-4200393 Porto, Portugal
关键词
shear bond strength; adhesion; active self-ligating brackets; passive self-ligating brackets; conventional brackets; tensile strength; maximum load; testing machine; ORTHODONTIC BRACKETS; BASE DESIGN; ENAMEL; TOOTH;
D O I
10.3390/dj10100196
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Adhesion remains a key element in dentistry, whether approached in prosthetics, odontology, or orthodontics. It is a continuously researched aspect, as improved materials and adhesive methods keep emerging in the market. No orthodontic treatment can be effective without the proper adhesion strength of the bonded elements on the teeth. The objective of this research, in the broad context of self-ligating versus conventional brackets, was to compare active and passive self-ligating systems with a conventional one by conducting an in vitro study on human-extracted premolars. Shear bond strength tests were executed by means of an advanced materials-testing machine that generated maximum load and tensile strength values. The data obtained underwent statistical analysis with a statistical threshold of p < 0.05. The results regarding the statistical significance were acquired when comparing the passive self-ligating system with the active self-ligating and conventional systems (load-at-maximum-load mean 204.9, SD 91.09, and p < 0.05). In this study, the passive self-ligating bracket system appears to present increased shear bond strength.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Torque capabilities of self-ligating and conventional brackets under the effect of bracket width and free wire length
    Huang, Y.
    Keilig, L.
    Rahimi, A.
    Reimann, S.
    Bourauel, C.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2012, 15 (04) : 255 - 262
  • [32] Self-ligating vs conventional brackets as perceived by orthodontists
    Prettyman, Chase
    Best, Al M.
    Lindauer, Steven J.
    Tufekci, Eser
    ANGLE ORTHODONTIST, 2012, 82 (06) : 1060 - 1066
  • [33] Microbial complexes levels in conventional and self-ligating brackets
    Ana Zilda Nazar Bergamo
    Paulo Nelson-Filho
    Marcela Cristina Damião Andrucioli
    Cássio do Nascimento
    Vinícius Pedrazzi
    Mírian Aiko Nakane Matsumoto
    Clinical Oral Investigations, 2017, 21 : 1037 - 1046
  • [34] Bond failure rates of two self-ligating brackets: a randomised clinical trial
    Chapman, J. Luke
    AUSTRALASIAN ORTHODONTIC JOURNAL, 2011, 27 (02): : 139 - 144
  • [35] A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type
    Lee, Souk Min
    Hwang, Chung-Ju
    KOREAN JOURNAL OF ORTHODONTICS, 2015, 45 (01) : 13 - 19
  • [36] Bond failure rates of two self-ligating brackets: a randomised clinical trial
    Chapman, J. Luke
    AUSTRALIAN ORTHODONTIC JOURNAL, 2011, 27 (02) : 139 - 144
  • [37] Microbial complexes levels in conventional and self-ligating brackets
    Nazar Bergamo, Ana Zilda
    Nelson-Filho, Paulo
    Damiao Andrucioli, Marcela Cristina
    do Nascimento, Cassio
    Pedrazzi, Vinicius
    Nakane Matsumoto, Mirian Aiko
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1037 - 1046
  • [38] Comparative assessment of forces generated during simulated alignment with self-ligating and conventional brackets
    Pandis, Nikolaos
    Eliades, Theodore
    Bourauel, Christoph
    EUROPEAN JOURNAL OF ORTHODONTICS, 2009, 31 (06) : 590 - 595
  • [39] Passive Self-Ligating Bracket Systems: A Scoping Review of Their Claims Regarding Efficiency and Effectiveness in Orthodontic Treatment
    Cernei, Eduard Radu
    Chehab, Alice
    Olteanu, Daniel Nicolae
    Romanec, Cristian
    Panaite, Tinela
    Zetu, Irina Nicoleta
    APPLIED SCIENCES-BASEL, 2023, 13 (10):
  • [40] In-vivo evaluation of salivary nickel and chromium levels in conventional and self-ligating brackets
    Sahoo, Nivedita
    Kailasam, Vignesh
    Padmanabhan, Sridevi
    Chitharanjan, Arun B.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (03) : 340 - 345