The influence of random packed column parameters on the liquid holdup and interfacial area

被引:7
|
作者
Fu, Yucheng [1 ]
Bao, Jie [1 ]
Singh, Rajesh Kumar [1 ]
Zheng, Richard Feng [1 ]
Anderson-Cook, Christine M. [2 ]
Bhat, K. Sham [2 ]
Xu, Zhijie [1 ]
机构
[1] Pacific Northwest Natl Lab, Richland, WA 99352 USA
[2] Los Alamos Natl Lab, Los Alamos, NM USA
关键词
computational fluid dynamics; design of experiments; interfacial area; liquid holdup; random packed column; MASS-TRANSFER AREA; STRUCTURED PACKINGS; HIERARCHICAL CALIBRATION; SURFACE-TENSION; FLUID-DYNAMICS; PRESSURE-DROP; FILM FLOWS; MODEL; ABSORPTION; HYDRODYNAMICS;
D O I
10.1002/aic.17691
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Carbon dioxide capture via solvent absorption in packed columns has emerged as a potential technology to mitigate coal-fired power plant CO2 emissions. Parameters, including packing types, solvent properties, and operating conditions, could potentially affect the packed column CO2 capture efficiency. To understand the importance of those parameters and help packed column optimization, a design of experiments (DoEs) method was proposed to generate input parameter matrix. Combined with multiphase computational fluid dynamics (CFD), the random packed column parameter influence on the liquid holdup and interfacial area can be efficiently investigated. Surrogate-based sensitivity analysis shows that the solvent flow rate and contact angle are key factors dictating liquid holdup and interfacial area. On the other hand, solvent viscosity has a marginal impact on the interfacial area. The sensitivity scores were calculated for each input parameter to guide the selection of dimensionless numbers for the liquid holdup and interfacial area correlation development.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Effective interfacial area and liquid holdup of nutter rings at high liquid loads
    Duss, M
    Meierhofer, H
    Nutter, DE
    CHEMICAL ENGINEERING & TECHNOLOGY, 2001, 24 (07) : 716 - 723
  • [22] EFFECTIVE INTERFACIAL AREA AND LIQUID AND GAS SIDE MASS-TRANSFER COEFFICIENTS IN A PACKED-COLUMN
    SAHAY, BN
    SHARMA, MM
    CHEMICAL ENGINEERING SCIENCE, 1973, 28 (01) : 41 - 47
  • [23] HOLDUP OF O/W EMULSION IN A PACKED-COLUMN FOR LIQUID MEMBRANE SEPARATION OF HYDROCARBON
    EGASHIRA, R
    SUGIMOTO, T
    KAWASAKI, J
    KAGAKU KOGAKU RONBUNSHU, 1993, 19 (04) : 676 - 679
  • [24] EFFECTIVE INTERFACIAL AREA IN PACKED LIQUID EXTRACTION COLUMNS
    PURANIK, SA
    SHARMA, MM
    CHEMICAL ENGINEERING SCIENCE, 1970, 25 (02) : 257 - &
  • [25] Liquid holdup and pressure drop in packed column with structured packing under offshore conditions
    Son, Yongho
    Won, Wangyun
    CHEMICAL ENGINEERING SCIENCE, 2019, 195 : 894 - 903
  • [26] Liquid holdup for two-phase countercurrent flow in the packed column with a novel internal
    Han, MH
    Lin, HF
    Wang, JF
    Jin, Y
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (17) : 4435 - 4438
  • [27] LIQUID-GAS INTERFACIAL AREA IN PACKED COLUMNS
    WEISMAN, J
    BONILLA, CF
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1950, 42 (06): : 1099 - 1105
  • [28] Liquid holdup and flooding in packed towers
    Elgin, JC
    Weiss, FB
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1939, 31 : 435 - 445
  • [29] The static liquid holdup in packed columns
    Stein, WA
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 2000, 66 (03): : 129 - 137
  • [30] Experimental studies of liquid flow maldistribution in a random packed column
    Yin, FH
    Wang, ZC
    Afacan, A
    Nandakumar, K
    Chuang, KT
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2000, 78 (03): : 449 - 457