Stabilization of comfort and visual quality after the insertion of soft contact lenses

被引:2
|
作者
Carpena-Torres, Carlos [1 ]
Pastrana, Cristina [1 ]
Rodriguez-Pomar, Candela [1 ]
Serramito, Maria [1 ]
Carracedo, Gonzalo [1 ,2 ]
机构
[1] Univ Complutense Madrid, Fac Opt & Optometry, Dept Optometry & Vis, Ocupharm Res Grp, Madrid, Spain
[2] Univ Complutense Madrid, Fac Opt & Optometria, Dept Optometria & Vis, C-Arcos Jalon 118, Madrid 28037, Spain
来源
CONTACT LENS & ANTERIOR EYE | 2022年 / 45卷 / 04期
关键词
Comfort; Wettability; Contact lens; Hydrogel; Silicone hydrogel; TEAR FILM STABILITY; SILICONE HYDROGEL; DRY EYE;
D O I
10.1016/j.clae.2021.101498
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate comfort, visual function, and in vivo wettability after the insertion of hydrogel and silicone hydrogel contact lenses for a better understanding of how long practitioners should wait for the initial evaluation of soft contact lenses. Methods: A short-term prospective, contralateral, randomized, and participant-masked study was carried out. Twenty healthy participants (25.4 +/- 2.6 years) were evaluated after the insertion of two different soft contact lenses at different times (1, 5, 10, 20, 30 min). Ocufilcon D (hydrogel) and Somofilcon A (silicone hydrogel) contact lenses were randomly assigned to both eyes of the same participant. Comfort, visual function under photopic conditions in terms of high-contrast visual acuity, low-contrast visual acuity, contrast sensitivity, and in vivo wettability were measured. Results: There was an increase in comfort (p < 0.001), high-contrast visual acuity (p < 0.05), and contrast sensitivity (p < 0.001, only with silicone hydrogel) directly related to time after contact lens insertion. Besides, in vivo wettability suffered a statistically significant deterioration directly related to time with both contact lenses (p < 0.05). Except for comfort and contrast sensitivity, all the parameters stabilized their values 10 min after the insertion of both soft contact lenses. Additionally, in vivo wettability and visual acuity differences were found between hydrogel and silicone hydrogel contact lenses (p < 0.05). Conclusions: It would be possible to properly evaluate high-contrast visual acuity, low-contrast visual acuity, and in vivo wettability 10 min after the insertion of both soft contact lenses.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Visual performance and optical quality with soft lenses in keratoconus patients
    Jinabhai, Amit
    Radhakrishnan, Hema
    Tromans, Cindy
    O'Donnell, Clare
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (02) : 100 - 116
  • [32] Is soft toric contact lenses fitting a feasible option to improve optical quality and visual performance in corneal ectasia?
    Carballo-Alvarez, Jesus
    Mari-Ribas, Marina
    Martin-Gonzalez, Abel
    Batres, Laura
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (02):
  • [33] CORNEAL NEOVASCULARIZATION AFTER WEARING SOFT CONTACT-LENSES
    KONISZEWSKI, G
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1982, 181 (06) : 467 - 470
  • [34] Protective effect of soft contact lenses after Boston keratoprosthesis
    Kammerdiener, Leah L.
    Speiser, Jaime Lynn
    Aquavella, James V.
    Harissi-Dagher, Mona
    Dohlman, Claes H.
    Chodosh, James
    Ciolino, Joseph B.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (04) : 549 - 552
  • [35] SOFT CONTACT-LENSES
    不详
    PRACTITIONER, 1977, 219 (1309) : 11 - 11
  • [36] SOFT HYDROPHILIC CONTACT LENSES
    JOHNSON, DG
    CANADIAN JOURNAL OF OPHTHALMOLOGY, 1971, 6 (04): : 342 - &
  • [37] SOFT CONTACT-LENSES
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1977, 2 (6088): : 655 - 656
  • [38] SOFT CONTACT-LENSES
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1972, 3 (5821): : 254 - +
  • [39] SOFT CONTACT-LENSES
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1976, 1 (6010): : 609 - 610
  • [40] SOFT CONTACT-LENSES
    CURTIS, FJ
    BRITISH MEDICAL JOURNAL, 1977, 2 (6095): : 1154 - 1154