Predictability of European air quality:: Assessment of 3 years of operational forecasts and analyses by the PREV'AIR system

被引:120
|
作者
Honore, Cecile [1 ]
Rouil, Laurence [1 ]
Vautard, Robert [2 ]
Beekmann, Matthias [3 ]
Bessagnet, Bertrand [1 ]
Dufour, Anne [4 ]
Elichegaray, Christian [5 ]
Flaud, Jean-Marie [3 ]
Malherbe, Laure [1 ]
Meleux, Frederik [1 ]
Menut, Laurent [6 ]
Martin, Daniel [4 ]
Peuch, Aline [4 ]
Peuch, Vincent-Henri [4 ]
Poisson, Nathalie [5 ]
机构
[1] Inst Natl Environm Ind Risques, Chron Risks Div, F-60550 Verneuil En Halatte, France
[2] Ctr Etud Saclay, Lab Sci Climat Environm, Inst Pierre Simon Laplace, F-91190 Gif Sur Yvette, France
[3] Fac Sci & Technol, Lab Interuniv Syst Atmospher, F-94010 Creteil, France
[4] Meteo France, F-75007 Paris, France
[5] Agence Environm & Maitrise Energie, F-75737 Paris 15, France
[6] Ecole Polytech, Inst Pierre Simon Laplace, Meteorol Dynam Lab, F-91128 Palaiseau, France
关键词
D O I
10.1029/2007JD008761
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
For the first time, the long-term evaluation of an operational real-time air quality forecasting and analysis system is presented, using error statistics over 3 consecutive years. This system, called PREV'AIR, is the French air quality forecasting and monitoring system. It became operational in 2003 as a result of a cooperation between several public organizations. The system forecasts and analyzes air quality throughout Europe, with a zoom over France, for regulatory pollutants: ozone (O-3), particulate matter with diameter smaller than 10 mu m (PM10), and nitrogen dioxide (NO2). The ability of PREV'AIR to forecast, up to 3 days ahead, photochemical and particle pollution over the domains considered is demonstrated: daily ozone maxima forecasts correlate with observations with 0.75-0.85 mean coefficients; U. S. Environmental Protection Agency acceptance criteria relative to the forecast accuracy for high concentrations and daily maxima are met for more than 90% of the measurement sites. For NO2 and PM10, the performance corresponds to the state of the art. The contribution of weather forecast errors to air quality predictability is addressed: ozone daily maxima forecast errors are not dominated by meteorological forecast errors; for rural stations, only 6% (15% and 25%, respectively) of the error variance is due to meteorological forecast errors on the first 24 (48 and 72, respectively) hours. The Model Output Statistics procedure, implemented in PREV'AIR, is proved to improve ozone forecasts, especially when photochemical pollution episodes occur. The PREV'AIR real-time analysis procedure, based on a kriging method, provides an accurate and comprehensive description of surface ozone fields over France.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] An operational real-time air quality modelling system for industrial plants
    San Jose, R.
    Perez, J. L.
    Gonzalez, R. M.
    ENVIRONMENTAL MODELLING & SOFTWARE, 2007, 22 (03) : 297 - 307
  • [22] Using synoptic classification to evaluate an operational air quality forecasting system in Atlanta
    Hu, Yongtao
    Chang, Michael E.
    Russell, Armistead G.
    Odman, M. Talat
    ATMOSPHERIC POLLUTION RESEARCH, 2010, 1 (04) : 280 - 287
  • [23] Assessment of indoor air quality in comparison using air conditioning and fan system in printing premise
    Ramlan, Nazirah
    Ahmad, Siti Nurhalimatul Husna
    Aminuddin, Eeydzah
    Hamid, Hazrul Abdul
    Yaman, Siti Khalijah
    Abdullah, Abd Halid
    SRIWIJAYA INTERNATIONAL CONFERENCE ON ENGINEERING, SCIENCE AND TECHNOLOGY (SICEST 2016), 2017, 101
  • [24] OPERATIONAL AIR-QUALITY MODELING SYSTEM FOR PHOTO-CHEMICAL SMOG IN SAN-DIEGO AIR BASIN
    SKLAREW, RC
    JONCICH, MA
    TRAN, KT
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1978, 59 (09) : 1238 - 1238
  • [25] Indoor Air Quality Assessment in an Art Gallery with an HVAC System
    Cai, Wei
    Wang, Danjun
    Wen, Xiaodong
    Yu, Xubo
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [26] Integrated decision support system for urban air quality assessment
    Lim, LL
    Hughes, SJ
    Hellawell, EE
    ENVIRONMENTAL MODELLING & SOFTWARE, 2005, 20 (07) : 947 - 954
  • [27] Assessment of air quality sensor system performance after relocation
    Zauli-Sajani, Stefano
    Marchesi, Stefano
    Pironi, Claudia
    Barbieri, Carla
    Poluzzi, Vanes
    Colacci, Annamaria
    ATMOSPHERIC POLLUTION RESEARCH, 2021, 12 (02) : 282 - 291
  • [28] Air quality assessment using a weighted Fuzzy Inference System
    Angel Olvera-Garcia, Miguel
    Carbajal-Hernandez, Jose J.
    Sanchez-Fernandez, Luis P.
    Hernandez-Bautista, Ignacio
    ECOLOGICAL INFORMATICS, 2016, 33 : 57 - 74
  • [29] Applying integrated assessment methodologies to air quality plans: Two European cases
    Miranda, A. I.
    Relvas, H.
    Viaene, P.
    Janssen, S.
    Brasseur, O.
    Carnevale, C.
    Declerck, P.
    Maffeis, G.
    Turrini, E.
    Volta, M.
    ENVIRONMENTAL SCIENCE & POLICY, 2016, 65 : 29 - 38
  • [30] Assessment of air quality within the framework of the European Union and its impact on Spain
    Fernandez Patier, Rosala
    REVISTA DE SALUD AMBIENTAL, 2015, 15 : 61 - 64